NONINVASIVE BLOOD PRESSURE MONITORING AND PREDICTION OF FLUID RESPONSIVENESS TO PASSIVE LEG RAISING

被引:13
|
作者
Pickett, Joya D. [1 ]
Bridges, Elizabeth [2 ,3 ]
Kritek, Patricia A. [4 ,5 ]
Whitney, JoAnne D. [2 ,6 ]
机构
[1] Swedish Med Ctr, 747 Broadway, Seattle, WA 98122 USA
[2] Univ Washington, Sch Nursing, Seattle, WA 98195 USA
[3] Univ Washington, Med Ctr, Univ Washington Med, Seattle, WA 98195 USA
[4] Univ Washington, Med Ctr, Crit Care, Seattle, WA 98195 USA
[5] Univ Washington, Med Ctr, Div Pulm & Crit Care Med, Seattle, WA 98195 USA
[6] Univ Washington Med, Harborview Med Ctr, Crit Care Nursing, Seattle, WA USA
关键词
CARDIAC-OUTPUT; VOLUME RESPONSIVENESS; DYNAMIC CHANGES; SEVERE SEPSIS; METAANALYSIS; BIOREACTANCE;
D O I
10.4037/ajcc2018867
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Intravenous fluid boluses are administered to patients in shock to improve tissue hypoperfusion. However, fluid boluses result in clinically significant stroke volume increases in only about 50% of patients. Hemodynamic responses to passive leg raising measured with invasive and minimally invasive methods are accurate predictors of fluid responsiveness. However, few studies have used noninvasive blood pressure measurement to evaluate responses to passive leg raising. Objective To determine if passive leg raising-induced increases in pulse pressure or systolic blood pressure can be used to predict clinically significant increases in stroke volume index in healthy volunteers. Methods In a repeated-measures study, hemodynamic measurements were obtained in 30 healthy volunteers before, during, and after passive leg raising. Each participant underwent the procedure twice. Results In the first test, 20 participants (69%) were responders (stroke volume index increased by >= 15%); 9 (31%) were nonresponders. In the second test, 15 participants (50%) were responders and 15 (50%) were nonresponders. A passive leg raising-induced increase in pulse pressure of 9% or more predicted a 15% increase in stroke volume index (sensitivity, 50%; specificity, 44%).There was no association between passive leg raising-induced changes in systolic blood pressure and fluid responsiveness. Conclusion A passive leg raising-induced change in stroke volume index measured by bioreactance differentiated fluid responders and nonresponders. Pulse pressure and systolic blood pressure measured by oscillometric noninvasive blood pressure monitoring were not sensitive or specific predictors of fluid responsiveness in healthy volunteers.
引用
收藏
页码:228 / 237
页数:10
相关论文
共 50 条
  • [1] Passive Leg-Raising and Prediction of Fluid Responsiveness
    Picket, J. D.
    Bridges, E.
    Kritek, P. A.
    Whitney, J. D.
    CRITICAL CARE NURSE, 2017, 37 (02) : 48 - 48
  • [2] Passive leg raising for monitoring volume status and predicting fluid responsiveness
    Kuschner, Ware G.
    CRITICAL CARE MEDICINE, 2011, 39 (02) : 420 - 420
  • [3] Passive Leg-Raising and Prediction of Fluid Responsiveness: Systematic Review
    Pickett, Joya D.
    Bridges, Elizabeth
    Kritek, Patricia A.
    Whitney, JoAnne D.
    CRITICAL CARE NURSE, 2017, 37 (02) : 32 - 47
  • [4] Accuracy of Passive Leg Raising Test in Prediction of Fluid Responsiveness in Children
    El-Nawawy, Ahmed A.
    Farghaly, Passant M.
    Hassouna, Hadir M.
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2020, 24 (05) : 344 - 349
  • [5] Passive Leg Raising for Fluid Responsiveness in Children: Is it Reliable?
    Ismail, Javed
    Bansal, Arun
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2020, 24 (05) : 291 - 292
  • [6] Passive leg raising induced-changes in blood pressure predict fluid responsiveness following cardiac surgery
    Fischer, M. -O
    Lemetayer, C.
    Gerard, J. -L
    Hanouz, J. -L
    Fellahi, J. -L
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 : 59 - 59
  • [7] Passive leg raising predicts fluid responsiveness in the critically ill
    Monnet, X
    Rienzo, M
    Osman, D
    Anguel, N
    Richard, C
    Pinsky, MR
    Teboul, JL
    CRITICAL CARE MEDICINE, 2006, 34 (05) : 1402 - 1407
  • [8] Passive leg raising predicts fluid responsiveness after cardiac surgery
    F Galas
    L Hajjar
    T Polastri
    T Faustino
    W Leao
    L Sampaio
    J Auler
    Critical Care, 12 (Suppl 2):
  • [9] Passive leg raising as an indicator of fluid responsiveness in patients with severe sepsis
    Dong, Zhou-zhou
    Fang, Qiang
    Zheng, Xia
    Shi, Heng
    WORLD JOURNAL OF EMERGENCY MEDICINE, 2012, 3 (03) : 191 - 196
  • [10] Passive leg raising for predicting fluid responsiveness: importance of the postural change
    Jabot, Julien
    Teboul, Jean-Louis
    Richard, Christian
    Monnet, Xavier
    INTENSIVE CARE MEDICINE, 2009, 35 (01) : 85 - 90