Frequency-stabilized chemical exchange saturation transfer imaging with real-time free-induction-decay readout

被引:20
|
作者
Liu, Ruibin [1 ]
Zhang, Hongxi [2 ]
Qian, Yue [3 ]
Hsu, Yi-Cheng [4 ]
Fu, Caixia [5 ]
Sun, Yi [4 ]
Wu, Dan [1 ]
Zhang, Yi [1 ]
机构
[1] Zhejiang Univ, Coll Biomed Engn & Instrument Sci, Dept Biomed Engn, Key Lab Biomed Engn,Minist Educ, Hangzhou, Zhejiang, Peoples R China
[2] Zhejiang Univ, Sch Med, Childrens Hosp, Dept Radiol, Hangzhou, Zhejiang, Peoples R China
[3] Zhejiang Univ, Sch Med, Sir Run Run Shaw Hosp, Dept Radiol, Hangzhou, Zhejiang, Peoples R China
[4] Siemens Healthcare Ltd, MR Collaborat, Shanghai, Peoples R China
[5] Siemens Shenzhen Magnet Resonance Ltd, Shenzhen, Peoples R China
基金
中国国家自然科学基金;
关键词
chemical exchange saturation transfer (CEST); free-induction-decay (FID) readout; frequency stabilization; temporal B(0)drift; AMIDE PROTON-TRANSFER; CEST-MRI; WEIGHTED MRI; BRAIN-TUMORS; IN-VIVO; PH; B-0; CONTRAST; SHIFT; WATER;
D O I
10.1002/mrm.28513
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To correct the temporal B(0)drift in chemical exchange saturation transfer (CEST) imaging in real-time with extra free-induction-decay (FID) readout. Theory and Methods The frequency stabilization module of the recently proposed frequency-stabilized CEST (FS-CEST) sequence was further simplified by replacing the original three k-space lines of gradient-echo (GRE) readout with a single k-space line of FID readout. The B(0)drift was quantified using the phase difference between the odd and even parts of the FID signal in the frequency stabilization module and then used to update the B(0)frequency in the succeeding modules. The proposed FS-CEST sequence with FID readout (FID FS-CEST) was validated in phantoms and 16 human subjects on cross-vendor scanners. Results In the Siemens experiments, the FID FS-CEST sequence successfully corrected the user-induced B(0)drift, generating consistent amide proton transfer-weighted (APTw) images and magnetization transfer ratio asymmetry (MTRasym) spectra with those from the non-frequency-stabilized CEST (NFS-CEST) sequence without B(0)drift. In the Philips experiments, the FID FS-CEST sequence produced more stable APTw images and MTR(asym)spectra than the NFS-CEST sequence in the presence of practical B(0)drift. Quantitatively, the SD of the APTw signal values in the deep gray matter from 15 subjects was 0.26% for the FID FS-CEST sequence compared to 1.03% for the NFS-CEST sequences, with the fluctuations reduced by nearly three-quarters. Conclusions The proposed FS-CEST sequence with FID readout can effectively correct the temporal B(0)drift on cross-vendor scanners.
引用
收藏
页码:1322 / 1334
页数:13
相关论文
共 16 条
  • [1] Improved chemical exchange saturation transfer imaging with real-time frequency drift correction
    Liu, Ruibin
    Zhang, Hongxi
    Niu, Weiming
    Lai, Can
    Ding, Qiuping
    Chen, Weibo
    Liang, Sayuan
    Zhou, Jinyuan
    Wu, Dan
    Zhang, Yi
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (05) : 2915 - 2923
  • [2] Improved chemical exchange saturation transfer imaging with real-time frequency drift correction (vol 81, pg 2915, 2019)
    Liu, Ruibin
    Zhang, Hongxi
    Niu, Weiming
    Lai, Can
    Ding, Qiuping
    Chen, Weibo
    Liang, Sayuan
    Zhou, Jinyuan
    Wu, Dan
    Zhang, Yi
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (05) : 1884 - 1884
  • [3] INFLUENCE OF FREQUENCY EXCHANGE-RATE ON FREE INDUCTION DECAY AFTER SATURATION
    BURSHTEIN, AI
    ZHARIKOV, AA
    MALINOVSKY, VS
    PHYSICAL REVIEW A, 1991, 43 (03): : 1538 - 1548
  • [4] Free-induction decay after a pulse saturation for systems with noncorrelated frequency exchange
    Malinovsky, VS
    Szabo, A
    PHYSICAL REVIEW A, 1997, 55 (05) : 3826 - 3831
  • [5] Free-induction decay after a pulse saturation for systems with noncorrelated frequency exchange
    Russian Acad of Sciences, Novosibirsk, Russia
    Phys Rev A, 5 (3826-3831):
  • [6] Whole-brain chemical exchange saturation transfer imaging with optimized turbo spin echo readout
    Zhang, Yi
    Yong, Xingwang
    Liu, Ruibin
    Tang, Jibin
    Jiang, Hongjie
    Fu, Caixia
    Wei, Ruili
    Hsu, Yi-Cheng
    Sun, Yi
    Luo, Benyan
    Wu, Dan
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (03) : 1161 - 1172
  • [7] Frequency importance analysis for chemical exchange saturation transfer magnetic resonance imaging using permuted random forest
    Chen, Yibing
    Dang, Xujian
    Zhao, Benqi
    Chen, Zhensen
    Zhao, Yingcheng
    Zhao, Fengjun
    Zheng, Zhuozhao
    He, Xiaowei
    Peng, Jinye
    Song, Xiaolei
    NMR IN BIOMEDICINE, 2023, 36 (06)
  • [8] Free-breathing abdominal chemical exchange saturation transfer imaging using water presaturation and respiratory gating at 3.0 T
    Chen, Zhensen
    Liu, Chuyu
    Wang, Yishi
    Guo, Rui
    Chen, Weibo
    Wang, He
    Song, Xiaolei
    NMR IN BIOMEDICINE, 2024, 37 (08)
  • [9] Quantifying exchange rates in chemical exchange saturation transfer agents using the saturation time and saturation power dependencies of the magnetization transfer effect on the magnetic resonance imaging signal (QUEST and QUESP): pH calibration for poly-L-lysine and a starburst dendrimer
    McMahon, MT
    Gilad, AA
    Zhou, JY
    Sun, PZ
    Bulte, JWM
    van Zijl, PCM
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (04) : 836 - 847
  • [10] Towards robust glucose chemical exchange saturation transfer imaging in humans at 3 T: Arterial input function measurements and the effects of infusion time
    Seidemo, Anina
    Lehmann, Patrick M.
    Rydhog, Anna
    Wirestam, Ronnie
    Helms, Gunther
    Zhang, Yi
    Yadav, Nirbhay N.
    Sundgren, Pia C.
    van Zijl, Peter C. M.
    Knutsson, Linda
    NMR IN BIOMEDICINE, 2022, 35 (02)