Analysis of repaired reinforced concrete structures

被引:46
|
作者
Vecchio, FJ
Bucci, F
机构
[1] Univ Toronto, Dept Civil Engn, Toronto, ON M5S 1A4, Canada
[2] Univ Toronto, Dept Civil Engn, Toronto, ON M5S 1A4, Canada
来源
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | 1999年 / 125卷 / 06期
关键词
D O I
10.1061/(ASCE)0733-9445(1999)125:6(644)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A procedure is described by which nonlinear finite-element algorithms can be modified to enable the analysis of repaired or rehabilitated concrete structures, taking into account the chronology of the loading, damage, and repair. The method defines and employs plastic strain offsets in the context of a smeared rotating crack model. The ability to engage and disengage elements at various stages of loading, as well as the ability to carry forward strain measures representing previous loading and damage conditions, are key aspects in the analysis method. Analysis of beams and slabs repaired with fiber-reinforced plastics demonstrates the accuracy of the procedure in accounting for changes in strength, stiffness, ductility, and failure mode as a result of strengthening measures. Flexure-dominated and shear-dominated responses are equally well represented. The analysis of a repaired shear wall, subjected to reversed cyclic lends, illustrates the ability to model severely damaged structures where some portions must be removed and reconstructed. In all cases, the analysis procedure was numerically stable and efficient at all stages of loading.
引用
收藏
页码:644 / 652
页数:9
相关论文
共 50 条
  • [1] Diagnosing the cause of incipient anodes in repaired reinforced concrete structures
    Christodoulou, C.
    Goodier, C.
    Austin, S.
    Webb, J.
    Glass, G. K.
    CORROSION SCIENCE, 2013, 69 : 123 - 129
  • [2] Monitoring of repaired reinforced concrete structures by means of resistivity measurements
    Hunkeler, F
    ELECTROCHEMICAL METHODS IN CORROSION: RESEARCH AND APPLICATION, 1997, 247 : 93 - 106
  • [3] Analysis of safety of repaired reinforced concrete cooling towers
    Golczyk, M
    Abramek, W
    Centkowski, J
    NATURAL DRAUGHT COOLING TOWERS, 1996, : 277 - 281
  • [4] REPAIRED REINFORCED CONCRETE BEAMS
    Andrews, G.
    Sharma, A.K.
    Concrete International, 1988, 10 (04) : 47 - 51
  • [5] Investigations into the cause and consequence of incipient anodes in repaired reinforced concrete structures
    Christodoulou, C.
    Goodier, C., I
    Glass, G. K.
    CONCRETE REPAIR, REHABILITATION AND RETROFITTING IV, 2016, : 186 - 187
  • [6] Chloride redistribution in cracked and with W-Cl repaired reinforced concrete structures
    Osterminski, Kai
    Zausinger, Christoph
    Gehlen, Christoph
    BETON- UND STAHLBETONBAU, 2022, 117 (12) : 968 - 975
  • [7] REPAIRED REINFORCED-CONCRETE BEAMS
    BASUNBUL, IA
    GUBATI, AA
    ALSULAIMANI, GJ
    BALUCH, MH
    ACI MATERIALS JOURNAL, 1990, 87 (04) : 348 - 354
  • [8] Modeling of shear-critical reinforced concrete structures repaired with fiber-reinforced polymer composites
    Kim, Sang-Woo
    Vecchio, Frank J.
    JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (08) : 1288 - 1299
  • [9] PUSHOVER ANALYSIS FOR REINFORCED CONCRETE STRUCTURES
    Baciu, Catalin
    ICMT '07: INTERNATIONAL CONFERENCE ON MILITARY TECHNOLOGIES, 2007, : 111 - 117
  • [10] Cracking analysis of reinforced concrete structures
    Giry, Cedric
    Oliver-Leblond, Cecile
    Dufour, Frederic
    Ragueneau, Frederic
    EUROPEAN JOURNAL OF ENVIRONMENTAL AND CIVIL ENGINEERING, 2014, 18 (07) : 724 - 737