Accuracy of pedicle and mass screw placement in the spine without using fluoroscopy: a prospective clinical study

被引:41
|
作者
Kotil, Kadir [1 ]
Bilge, Turgay [1 ]
机构
[1] Haseki Educ & Res Hosp, Dept Neurosurg, TR-34728 Istanbul, Turkey
来源
SPINE JOURNAL | 2008年 / 8卷 / 04期
关键词
mass screw; pedicle screw; fluoroscopy; spine;
D O I
10.1016/j.spinee.2007.04.002
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Spinal instrumentation is accompanied by various problems, including screw malpositioning. One way of preventing this is the employment of intraoperative biplanar fluoroscopy. However, screw malpositioning despite the use of fluoroscopy has been reported, and exposure to radiation is another burden of this method. Therefore, the purpose of this article was to compare the results of instrumentation applications without using scopy versus the harmful effects of radiation exposed during spinal instrumentation. PURPOSE: The aim of this article was to review the literature and this is the first prospective clinical study performed on this subject. STUDY DESIGN: Patient report. PATIENT SAMPLE: One hundred thirty-two patients with spinal instrumentations were included. OUTCOME MEASURES: Radiological investigation with computed tomography (CT) scans was performed 2 days after the procedure. METHODS: Craniosacral posterior spinal instrumentation was performed without using scopy at the Neurosurgery Clinic of Haseki Training and Research Hospital between January 2000 and January 2005. Postoperative CT analyses were performed to evaluate whether the 527 screws used during posterior instrumentation in a total of 132 patients were positioned correctly. In all cases, the screw applications were performed with regard to anatomic landmarks, whereas the distances were determined according to lesion localizations. Screw malpositioning and the functional effects and relations with interactions with neurovascular structures were examined. At the end of the operations, all patients were examined with direct lateral roentgenograms and CT scans for the evaluation of screw positions. RESULTS: According to their locations, 75 cervical screwing in 24 patients, 32 upper thoracic screwing in 7 patients, 30 midthoracic screwing in 7 patients, 306 thoracolumbar screwing in 54 patients, and 84 sacral screwing in 40 patients were performed by the senior spinal surgeon (KK). Among all posterior spinal instrumentation applications, the cervical region analyses revealed penetration of the medial wall of vertebral foramen with two (0.4%) screws, penetration of the lateral wall with one (0.2%) screw, and protrusion into the vertebral foramen without vascular penetration with one (0.2%) screw, whereas in the upper thoracic region there was penetration into the lateral pedicle wall with one (0.2%) screw and deviation toward the disc space through the superior end plate with two (0.4%) screws. In the midthoracic region, there was penetration into the disc space with two (0.4%) screws in only one case, whereas in the thoracolumbar complex, there was deviation toward the superior end plate with seven (1.4%) screws in four cases, deviation toward the disc space with two (0.4%) screws, medial wall penetration with six (1.2%) screws (two of which caused nerve root irritation in three cases), and penetration of the lateral wall of pedicle with four (0.8%) screws. In the sacral instrumentations, malpositioning occurred with only two (0.4%) screws because of deviation toward the medial wall. In summary, malpositioning occurred with 30 (5.6%) of the total 527 screws; none of the cases had neural or vascular damage. Two (1.5%) cases were revised for inalpositioning and distance errors. The mean duration for preparation of screw introduction site and placement of the screw was 3 minutes. Infection occurred in only one (0.75%) case. CONCLUSIONS: Screw application without fluoroscopy is performed with calculation of all essential anatomic details, and because of the reduction of surgery time, the absence of exposure to radiation, and very low infection rates as a consequence of reduced surgery time, it is a method recommendable for surgeons experienced with screw placement. Besides, its malpositioning rates are within acceptable limits. Because screw malpositioning is also found after biplanar fluoroscopy, the prevention of screw malpositioning requires knowing the anatomic landmarks accurately. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:591 / 596
页数:6
相关论文
共 50 条
  • [1] Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine
    Conrads, Nora
    Grunz, Jan-Peter
    Huflage, Henner
    Luetkens, Karsten Sebastian
    Feldle, Philipp
    Grunz, Katharina
    Koehler, Stefan
    Westermaier, Thomas
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (06) : 3007 - 3013
  • [2] Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine
    Nora Conrads
    Jan-Peter Grunz
    Henner Huflage
    Karsten Sebastian Luetkens
    Philipp Feldle
    Katharina Grunz
    Stefan Köhler
    Thomas Westermaier
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 3007 - 3013
  • [3] Accuracy of 'O arm' guided pedicle screw placement in osteoporotic spine with the 'precious pedicle'
    Hadgaonkar, Shailesh
    Modipalli, Divakar
    Sancheti, Parag
    Kothari, Ajay
    Aiyer, Siddharth
    Shyam, Ashok
    Acharya, Hriday
    INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT, 2022, 27
  • [4] Accuracy and technical limits of percutaneous pedicle screw placement in the thoracolumbar spine
    Yann Philippe Charles
    Yves Ntilikina
    Arnaud Collinet
    Sébastien Schuller
    Julien Garnon
    Julien Godet
    Philippe Clavert
    Surgical and Radiologic Anatomy, 2021, 43 : 843 - 853
  • [5] Accuracy of Pedicle Screw Placement in Thoracolumbar Spine with Conventional Open Technique
    Borcek, Alp Ozgun
    Suner, Halil Ibrahim
    Emmez, Hakan
    Kaymaz, Memduh
    Aykol, Sukru
    Pasaoglu, Aydin
    TURKISH NEUROSURGERY, 2014, 24 (03) : 398 - 402
  • [6] Accuracy and technical limits of percutaneous pedicle screw placement in the thoracolumbar spine
    Charles, Yann Philippe
    Ntilikina, Yves
    Collinet, Arnaud
    Schuller, Sebastien
    Garnon, Julien
    Godet, Julien
    Clavert, Philippe
    SURGICAL AND RADIOLOGIC ANATOMY, 2021, 43 (06) : 843 - 853
  • [7] Accuracy and Safety of Percutaneous Lumbosacral Pedicle Screw Placement Using Dual-Planar Intraoperative Fluoroscopy
    Dunn, Conor
    Faloon, Michael
    Milman, Edward
    Pourtaheri, Sina
    Sinah, Kumar
    Hwang, Ki
    Emami, Arash
    ASIAN SPINE JOURNAL, 2018, 12 (02) : 238 - 245
  • [8] The accuracy of pedicle screw placement in the thoracic spine using the "funnel technique" - Part 1. A cadaveric study
    Yingsakmonkol, W
    Karaikovic, T
    Gaines, RW
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2002, 15 (06): : 445 - 449
  • [9] Percutaneous Pedicle Screw Placement Aided by a New Drill Guide Template Combined with Fluoroscopy: An Accuracy Study
    Wu, Chao
    Deng, Jiayan
    Li, Tao
    Tan, Lun
    Yuan, Dechao
    ORTHOPAEDIC SURGERY, 2020, 12 (02) : 471 - 479
  • [10] Appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study
    Wei-Xing Xu
    Wei-Guo Ding
    Bin Xu
    Tian-Hong Hu
    Hong-Feng Sheng
    Jia-Fu Zhu
    Xiao-Long Zhu
    BMC Musculoskeletal Disorders, 21