Lowering the outdoor temperature in high-rise high-density residential developments of coastal Hong Kong: The vegetation influence

被引:109
|
作者
Giridharan, R. [1 ]
Lau, S. S. Y. [2 ]
Ganesan, S. [2 ]
Givoni, B. [3 ]
机构
[1] Brunel Univ, Sch Engn & Design, Uxbridge UB8 3PH, Middx, England
[2] Univ Hong Kong, Dept Architecture, Hong Kong, Hong Kong, Peoples R China
[3] Chinese Univ Hong Kong, Dept Architecture, Hong Kong, Hong Kong, Peoples R China
关键词
On-site variables; Urban heat island intensity (UHI); Tree cover; Shrub cover; Peak summer clear sky days (PSCS-days); Peak summer partially cloudy days (PSPC-days); Late summer days;
D O I
10.1016/j.buildenv.2007.10.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates the impact of on-site variables on the influence of vegetation in lowering outdoor temperature. The study uses six critical on-site variables such as surface albedo, sky view factor, altitude, shrub cover, tree cover and average height to floor area ratio to carry out analysis in five data sets. The climatic parameters and physical characteristics were measured and surveyed, respectively in 216 stations in high-rise high-density residential developments of coastal Hong Kong. The data set is mainly categorised into peak summer clear sky days (PSCS-days), peak summer partially cloudy days (PSPC-days) and late summer days to address the issues related to cloudy sky conditions in Hong Kong. The trend analysis shows that at a lower sky view factor, ranging from 0. 1 to 0.25, shrub cover as low as 10-15% in a 1000 m(2) open area is more effective in reducing outdoor temperature than the same level of tree cover in a location with a higher sky view factor (0.4 or above). The regression models used in this study were able to explain the influence of on-site variables on vegetation in lowering the outdoor temperature within the respective urban settings. In high-rise high-density environments, on-site variables such as sky view factor and altitude have a substantial impact on the influence of vegetation in lowering outdoor temperature. However, off-site variables such as high urban density and anthropogenic heat could negate the behaviour of sky view factor and altitude. The study suggests that increasing the tree cover from 25% to 40% in the pocket parks in coastal area residential developments of Hong Kong could reduce daytime urban heat island intensity (UHI) by further 0.5 degrees C. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1583 / 1595
页数:13
相关论文
共 50 条
  • [1] Daytime urban heat island effect in high-rise and high-density residential developments in Hong Kong
    Giridharan, R
    Ganesan, S
    Lau, SSY
    ENERGY AND BUILDINGS, 2004, 36 (06) : 525 - 534
  • [2] Air quality and high-rise high-density residential environment in Hong Kong
    Edussuriya, PS
    Ye, AM
    Chan, ATY
    TALL BUILDINGS: FROM ENGINEERING TO SUSTAINABILITY, 2005, : 942 - 950
  • [3] Impact of unit type and configuration on indoor natural ventilation performance of high-rise, high-density residential buildings in Hong Kong
    Lin, Pingying
    Qin, Hao
    Lau, Sunnie Sing Yeung
    Wei, Qin
    BUILDING AND ENVIRONMENT, 2025, 269
  • [4] Sustainable building retrofit model for high-rise, high-density city: a case in Hong Kong
    He, Qiong
    Hossain, Md. Uzzal
    Ng, S. Thomas
    Augenbroe, Godfried
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-ENGINEERING SUSTAINABILITY, 2021, 174 (02) : 69 - 82
  • [5] BUILDING IMPLEMENTATION IN HIGH-RISE RESIDENTIAL BUILDINGS IN HONG KONG
    Lau, Wai Kin
    Ho, Daneiel Chi Wing
    OPEN HOUSE INTERNATIONAL, 2011, 36 (01) : 25 - 34
  • [6] Energy behavior of high-rise residential units in Hong Kong
    Bojic, Milorad Lj
    Burnett, John
    Yik, Francis W. H.
    HKIE Transactions Hong Kong Institution of Engineers, 2001, 8 (01): : 23 - 27
  • [7] Implementing modular integrated construction in high-rise high-density cities: perspectives in Hong Kong
    Pan, Wei
    Yang, Yi
    Pan, Mi
    BUILDING RESEARCH AND INFORMATION, 2023, 51 (03): : 354 - 368
  • [8] Investigations of cooling loads in high-rise residential buildings in Hong Kong
    Bojic, M
    Yik, F
    Wan, K
    Burnett, J
    THERMAL SCIENCES 2000, 2000, : 505 - 510
  • [9] Investigation of cooling loads in high-rise residential buildings in Hong Kong
    Bojic, M
    Yik, F
    Wan, K
    Burnett, J
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2001, 47 (08): : 491 - 496
  • [10] Energy performance of windows in high-rise residential buildings in Hong Kong
    Bojic, M
    Yik, F
    Sat, P
    ENERGY AND BUILDINGS, 2002, 34 (01) : 71 - 82