Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis

被引:298
|
作者
Monnet, Xavier [1 ,2 ]
Marik, Paul [3 ]
Teboul, Jean-Louis [1 ,2 ]
机构
[1] Hop Univ Paris Sud, Hop Bicetre, Serv Reanimat Med, 78 Rue Gen Leclerc, F-94270 Le Kremlin Bicetre, France
[2] Univ Paris Sud, INSERM, Fac Med Paris Sud, UMR S 999, Le Kremlin Bicetre, France
[3] Eastern Virginia Med Sch, Dept Med, Div Pulm & Crit Care Med, Norfolk, VA 23501 USA
关键词
Passive leg raising; Meta-analysis; Fluid responsiveness; Volume expansion; END-EXPIRATORY OCCLUSION; CARDIAC-OUTPUT MEASUREMENTS; PULSE PRESSURE VARIATION; CRITICALLY-ILL PATIENTS; TIDAL CARBON-DIOXIDE; VOLUME RESPONSIVENESS; STROKE VOLUME; ARTERIAL-PRESSURE; SEVERE SEPSIS; BLOOD-FLOW;
D O I
10.1007/s00134-015-4134-1
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We performed a systematic review and meta-analysis of studies investigating the passive leg raising (PLR)-induced changes in cardiac output (CO) and in arterial pulse pressure (PP) as predictors of fluid responsiveness in adults. MEDLINE, EMBASE and Cochrane Database were screened for relevant original and review articles. The meta-analysis determined the pooled area under the ROC curve, the sensitivity, specificity and threshold for the PLR test when assessed with CO and PP. Twenty-one studies (991 adult patients, 995 fluid challenges) were included. CO was measured by echocardiography in six studies, calibrated pulse contour analysis in six studies, bioreactance in four studies, oesophageal Doppler in three studies, transpulmonary thermodilution or pulmonary artery catheter in one study and suprasternal Doppler in one study. The pooled correlation between the PLR-induced and the fluid-induced changes in CO was 0.76 (0.73-0.80). For the PLR-induced changes in CO, the pooled sensitivity was 0.85 (0.81-0.88) and the pooled specificity was 0.91 (0.88-0.93). The area under the ROC curve was 0.95 +/- A 0.01. The best threshold was a PLR-induced increase in CO aeyen10 +/- A 2 %. For the PLR-induced changes in PP (8 studies, 432 fluid challenges), the pooled sensitivity was 0.56 (0.49-0.53), the pooled specificity was 0.83 (0.77-0.88) and the pooled area under the ROC curve was 0.77 +/- A 0.05. Sensitivity and subgroup analysis were consistent with the primary analysis. PLR-induced changes in CO very reliably predict the response of CO to volume expansion in adults with acute circulatory failure. When PLR effects are assessed by changes in PP, the specificity of the PLR test remains acceptable but its sensitivity is poor.
引用
收藏
页码:1935 / 1947
页数:13
相关论文
共 50 条
  • [1] Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis
    X Monnet
    J-L Teboul
    Intensive Care Medicine Experimental, 3 (Suppl 1)
  • [2] Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis
    Xavier Monnet
    Paul Marik
    Jean-Louis Teboul
    Intensive Care Medicine, 2016, 42 : 1935 - 1947
  • [3] Predicting Fluid Responsiveness by Passive Leg Raising: A Systematic Review and Meta-Analysis of 23 Clinical Trials
    Cherpanath, Thomas G. V.
    Hirsch, Alexander
    Geerts, Bart F.
    Lagrand, Wim K.
    Leeflang, Mariska M.
    Schultz, Marcus J.
    Groeneveld, A. B. Johan
    CRITICAL CARE MEDICINE, 2016, 44 (05) : 981 - 991
  • [4] Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies
    Cavallaro, Fabio
    Sandroni, Claudio
    Marano, Cristina
    La Torre, Giuseppe
    Mannocci, Alice
    De Waure, Chiara
    Bello, Giuseppe
    Maviglia, Riccardo
    Antonelli, Massimo
    INTENSIVE CARE MEDICINE, 2010, 36 (09) : 1475 - 1483
  • [5] Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies
    Fabio Cavallaro
    Claudio Sandroni
    Cristina Marano
    Giuseppe La Torre
    Alice Mannocci
    Chiara De Waure
    Giuseppe Bello
    Riccardo Maviglia
    Massimo Antonelli
    Intensive Care Medicine, 2010, 36 : 1475 - 1483
  • [6] Passive Leg-Raising and Prediction of Fluid Responsiveness: Systematic Review
    Pickett, Joya D.
    Bridges, Elizabeth
    Kritek, Patricia A.
    Whitney, JoAnne D.
    CRITICAL CARE NURSE, 2017, 37 (02) : 32 - 47
  • [7] Value of variation of end-tidal carbon dioxide for predicting fluid responsiveness during the passive leg raising test in patients with mechanical ventilation: a systematic review and meta-analysis
    Haijun Huang
    Chenxia Wu
    Qinkang Shen
    Yixin Fang
    Hua Xu
    Critical Care, 26
  • [8] Value of variation of end-tidal carbon dioxide for predicting fluid responsiveness during the passive leg raising test in patients with mechanical ventilation: a systematic review and meta-analysis
    Huang, Haijun
    Wu, Chenxia
    Shen, Qinkang
    Fang, Yixin
    Xu, Hua
    CRITICAL CARE, 2022, 26 (01)
  • [9] Passive leg raising for monitoring volume status and predicting fluid responsiveness
    Kuschner, Ware G.
    CRITICAL CARE MEDICINE, 2011, 39 (02) : 420 - 420
  • [10] Passive leg raising for predicting fluid responsiveness: importance of the postural change
    Jabot, Julien
    Teboul, Jean-Louis
    Richard, Christian
    Monnet, Xavier
    INTENSIVE CARE MEDICINE, 2009, 35 (01) : 85 - 90