AdVance/AdVance XP Transobturator Male Slings: Preoperative Degree of Incontinence as Predictor of Surgical Outcome

被引:76
|
作者
Collado Serra, Argimiro [1 ]
Resel Folkersma, Luis
Dominguez-Escrig, Jose L.
Gomez-Ferrer, Alvaro
Rubio-Briones, Jose
Solsona Narbon, Eduardo
机构
[1] Fdn Inst Valenciano Oncol, Dept Urol, Valencia 46009, Spain
关键词
STRESS URINARY-INCONTINENCE; COMPLICATIONS; CONTINENCE; SUSPENSION;
D O I
10.1016/j.urology.2013.01.007
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE To evaluate the efficacy of the AdVance transobturator male sling in the treatment of male stress urinary incontinence and to identify the preoperative predictors of a successful outcome. MATERIALS AND METHODS All patients were considered for sling placement 1 year after radical prostatectomy or transurethral resection of the prostate. The degree of incontinence was assessed using the 24-hour pad weight test. A preoperative urodynamic assessment and cystoscopy were performed in all cases. Patients without sphincter contractions during the "repositioning test" were excluded. Since September 2010, we have implanted the AdVance XP transobturator sling. Cure was defined as no pad use. RESULTS From February 2008 to June 2011, 61 patients underwent transobturator sling (34 AdVance and 27 AdVance XP) insertion. In 26 cases, the sling was anchored with bioabsorbable sutures, and in 35 cases, it was not fixed. Of the 61 patients, 7 had a history of anastomotic stricture and 3 of radiotherapy. Preoperatively, median 24-hour pad weight was 200 g (range 25-1848). Finally, 26 patients had detrusor overactivity or low bladder compliance. The median follow-up was 26 months (range 12-53). The overall cure rate was 80% (49 of 61). Deterioration of continence was observed during follow-up in 2 patients. The preoperative variables (age, body mass index, 24-hour pad weight, International Consultation on Incontinence Questionnaire-Short Form, adverse urodynamics, sling fixation, AdVance XP) and their association with the surgical outcome were analyzed. The preoperative 24-hour pad weight correlated inversely with the outcome (odds ratio 0.996), with a 0.4% decrease in cure rate for each 1-g increase in the preoperative 24-hour pad weight. The complications included perineal hematoma in 2, acute urinary retention in 9, perineal numbness in 5, and de novo storage symptoms (urgency) in 5 patients. CONCLUSION The results of our study have shown that the AdVance and AdVance XP male slings are safe and efficient in patients with mild postprostatectomy stress incontinence. The severity of incontinence was the only predictor of a successful outcome. (C) 2013 Elsevier Inc.
引用
收藏
页码:1034 / 1039
页数:6
相关论文
共 50 条
  • [1] Re: AdVance/AdVance XP Transobturator Male Slings: Preoperative Degree of Incontinence as Predictor of Surgical Outcome Editorial Comment
    Morey, Allen F.
    JOURNAL OF UROLOGY, 2013, 190 (06): : 2146 - 2146
  • [2] AdVance and AdVance XP slings for the treatment of post-prostatectomy incontinence
    Ricarda M. Bauer
    Alexander Kretschmer
    Christian G. Stief
    Claudius Füllhase
    World Journal of Urology, 2015, 33 : 145 - 150
  • [3] AdVance and AdVance XP slings for the treatment of post-prostatectomy incontinence
    Bauer, Ricarda M.
    Kretschmer, Alexander
    Stief, Christian G.
    Fuellhase, Claudius
    WORLD JOURNAL OF UROLOGY, 2015, 33 (01) : 145 - 150
  • [4] DURABLE OUTCOMES USING ADVANCE TRANSOBTURATOR MALE SLINGS FOR MILD STRESS URINARY INCONTINENCE
    Zuckerman, Jack
    Edwards, Brooke
    McCammon, Kurt
    NEUROUROLOGY AND URODYNAMICS, 2014, 33 (02) : 246 - 246
  • [5] URETHRAL EROSION OF ADVANCE TRANSOBTURATOR MALE SLINGS: A REVIEW OF FIVE CASES
    Shah, Amul
    Guralnick, Michael
    O'Connor, R. Corey
    NEUROUROLOGY AND URODYNAMICS, 2013, 32 (02) : 148 - 149
  • [6] Complications of the AdVance Transobturator Male Sling in the Treatment of Male Stress Urinary Incontinence
    Morey, Allen F.
    JOURNAL OF UROLOGY, 2011, 185 (01): : 208 - 208
  • [7] Complications of the AdVance Transobturator Male Sling in the Treatment of Male Stress Urinary Incontinence
    Bauer, Ricarda M.
    Mayer, Margit E.
    May, Florian
    Gratzke, Christian
    Buchner, Alexander
    Soljanik, Irina
    Bastian, Patrick J.
    Stief, Christian G.
    Gozzi, Christian
    UROLOGY, 2010, 75 (06) : 1494 - 1498
  • [8] RESULTS OF THE ADVANCE XP SLING FOR THE TREATMENT OF MALE STRESS INCONTINENCE
    Bauer, R.
    Cordier, J.
    Becker, A.
    Stief, C.
    Roosen, A.
    NEUROUROLOGY AND URODYNAMICS, 2012, 31 (06) : 965 - 966
  • [9] LONG TERM FOLLOW UP OF POST PROSTATECTOMY INCONTINENCE IN A LARGE REAL-LIFE COHORT OF PATIENTS TREATED WITH ADVANCE® AND/OR ADVANCE XP® TRANSOBTURATOR MALE SLING
    Tasso, G.
    Del Favero, L.
    Hermans, B.
    Laenen, A.
    De Ridder, D.
    Van der Aa, F.
    NEUROUROLOGY AND URODYNAMICS, 2019, 38 : S257 - S259
  • [10] ADVANCE XP MALE SLING: OUTCOME OF A PROSPECTIVE MULTICENTER STUDY
    Bauer, Ricarda
    Klehr, Benedikt
    Gozzi, Christian
    Kretschmer, Alexander
    Rehder, Peter
    May, Florian
    Stief, Christian
    Homberg, Roland
    Gebhartl, Peter
    JOURNAL OF UROLOGY, 2015, 193 (04): : E1095 - E1096