An EGS4 Monte Carlo examination of the response of a PTW-diamond radiation detector in megavoltage electron beams

被引:20
|
作者
Mobit, PN
Sandison, GA
机构
[1] Tom Baker Canc Clin, Dept Med Phys, Calgary, AB T2N 4N2, Canada
[2] Univ Calgary, Dept Radiat Oncol, Calgary, AB T2N 4N2, Canada
关键词
Monte Carlo; perturbation; diamond detector;
D O I
10.1118/1.598593
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The EGS4 Monte Carlo code has been used to investigate the response of a PTW/diamond detector irradiated in both clinical and monoenergetic megavoltage electron beams ranging in energy from 5 to 20 MeV. The sensitive volume of the PTW/diamond detector simulated has a thickness of 0.4 mm and a diameter of 4.4 mm. Irradiation was simulated at various depths in a water phantom. The results show that the PTW/diamond detector has a constant response (within 1.0%) in electron beams if irradiated at depths closed to d(max), and its response is almost independent of irradiation depth or incident electron energy (within 3%). A detailed examination of the average detector dose shows that the sensitive volume of the PTW/diamond detector acts as a Spencer-Attix cavity within 1%. The encapsulation of the bare diamond detector with low-Z epoxy and polystyrene wall material does not affect its response in electron beams. The difference in response between the unencapsulated (TLD) and the encapsulated form of the detector is less than 0.5% for all depths over electron energy range investigated. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)00605-7].
引用
收藏
页码:839 / 844
页数:6
相关论文
共 27 条
  • [1] A Monte Carlo comparison of the response of the PTW-diamond and the TL-diamond detectors in megavoltage photon beams
    Mobit, PN
    Sandison, GA
    MEDICAL PHYSICS, 1999, 26 (11) : 2503 - 2507
  • [2] An EGS4 Monte Carlo examination of general cavity theory
    Mobit, PN
    Nahum, AE
    Mayles, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (07): : 1319 - 1334
  • [3] Application of unfolding technique to HPGe detector using response functions calculated with the EGS4 Monte Carlo code
    Chun, KJ
    Hah, SH
    Kim, HM
    Yoo, GH
    JOURNAL OF RADIATION RESEARCH, 2006, 47 (01) : 27 - 40
  • [4] Analysis of 4πγ ionization chamber response using EGS4 Monte Carlo code
    Suzuki, H
    Sibaike, K
    Hashimoto, H
    Kawada, Y
    Hino, Y
    APPLIED RADIATION AND ISOTOPES, 1998, 49 (9-11) : 1245 - 1249
  • [5] Monte Carlo simulation of electron beams for radiotherapy - EGS4, MCNP4b and GEANT3 intercomparison
    Trindade, A
    Rodrigues, P
    Alves, C
    Chaves, A
    Lopes, MC
    Oliveira, C
    Peralta, L
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 311 - 316
  • [6] Comparisons of clinical electron dose distributions between a commercial radiation treatment planning system and EGS4 Monte Carlo
    Holmes, M
    Mackie, TR
    Rogers, DWO
    Ding, G
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 54 - 56
  • [7] CALCULATION OF BETA DOSIMETRY IN RADIATION SYNOVECTOMY USING MONTE-CARLO SIMULATION (EGS4)
    JOHNSON, LS
    YANCH, JC
    MEDICAL PHYSICS, 1993, 20 (03) : 747 - 754
  • [8] Response calculation for standard ionization chambers in the APMP using EGS4 Monte Carlo code
    Sato, Yasushi
    Yunoki, Akira
    Hino, Yoshio
    Yamada, Takahiro
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (10-11) : 1211 - 1214
  • [9] Calculation of energy response of cylindrical G-M tubes with EGS4 Monte Carlo code
    Liu, BX
    Wang, YC
    Xie, B
    Zhang, H
    PROCEEDINGS OF CHEP 2001, 2001, : 354 - 356
  • [10] VERIFICATION OF AN INVERSE PROBLEM IN RADIATION-THERAPY DOSE CALCULATIONS USING THE EGS4 MONTE-CARLO
    KOOY, HM
    BARTH, NH
    MEDICAL PHYSICS, 1987, 14 (03) : 452 - 453