Study on the Laser Decontamination of Metal Surface at 1064 and 532 nm

被引:0
|
作者
Won, Hui-Jun [1 ]
Jung, Sun-Hee [1 ]
Jung, Chong-Hun [1 ]
Choi, Byung Seon [1 ]
Moon, Jei-Kwon [1 ]
Lee, Kune-Woo [1 ]
机构
[1] Korea Atom Energy Res Inst, Decontaminat & Decommissioning Technol Dev Div, Taejon 305353, South Korea
关键词
Decontamination; Q-Switched Nd:YAG laser; Ablation; Second harmonics; Irradiation angle; ABLATION;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Type 304 stainless steel is contaminated with CsNO3, Co(NH4)(2)(SO4)(2), CeO2 and Eu2O3. We present the experimental results on decontamination of contaminants attached to type 304 stainless steel surface by coherent light of 1064 nm wavelength and its second harmonic generation occurring at 532 nm derived from a Q-switched Nd:YAG laser. The surface morphology and the relative atomic molar percent of the specimen surface have been investigated by SEM and EPMA. The decontamination behaviour has been investigated for the variables such as a number of laser shots and fluence. The decontamination behaviour at 532 nm by varying the irradiation angle has also been investigated. The optimum laser fluence at 1064 nm wavelength is found to be 57.3 J/cm(2) and 97.7 % of Cs+ ion is removed during 40 laser shots. The optimum application condition at 532 nm wavelength is found to be 13.3 J/cm(2) and 30 degrees, respectively. The order of decontamination efficiency at 1064 nm is CsNO3 > Co(NH4)(2)(SO4)(2) > CeO2> Eu2O3 and at 532 nm is CsNO3 > Co(NH4)(2)(SO4)(2) > Eu2O3 > CeO2.
引用
收藏
页码:4136 / 4140
页数:5
相关论文
共 50 条
  • [1] COMPARISON STUDY OF A 532/1064nm PICOSECOND LASER vs A 532/1064nm NANOSECOND LASER IN THE TREATMENT OF BLACK TATTOOS IN ASIANS
    Kono, Taro
    Shek, Samantha
    Chan, Henry
    Groff, William
    Imagawa, Kotaro
    Miyasaka, Muneo
    LASERS IN SURGERY AND MEDICINE, 2016, 48 : 14 - 14
  • [2] Pulsed laser ablation of gold at 1064 nm an 532 nm
    Torrisi, L
    Picciotto, A
    Andó, L
    Gammino, S
    Margarone, D
    Láska, L
    Pfeifer, M
    Krása, J
    CZECHOSLOVAK JOURNAL OF PHYSICS, 2004, 54 : 421 - 430
  • [3] COMPARISON STUDY OF A 532/1064nm PICOSECOND LASER vs A 532/1064nm NANOSECOND LASER IN THE TREATMENT OF MULTI-COLORED TATTOOS IN ASIANS
    Kono, Taro
    Shek, Samantha
    Chan, Henry
    Groff, William
    Imagawa, Kotaro
    Miyasaka, Muneo
    LASERS IN SURGERY AND MEDICINE, 2016, 48 : 14 - 14
  • [4] Attenuation characterization of 532 nm and 1064 nm laser propagating in rain
    Guo, Jing
    Zhao, Xue-Jian
    OPTIK, 2016, 127 (20): : 9088 - 9094
  • [5] Laser damage resistance of dichroic mirrors at 532 nm and 1064 nm
    Cheng, Xinbin
    Shen, Zhengxiang
    Jiao, Hongfei
    Zhang, Jinlong
    Ma, Bin
    Ding, Tao
    Wang, Zhanshan
    LASER-INDUCED DAMAGE IN OPTICAL MATERIALS: 2010, 2010, 7842
  • [6] Spectroscopic study of a lead plasma produced by the 1064 nm, 532 nm and 355 nm of a Nd:YAG laser
    Shaikh, Nek. M.
    Kalhoro, M. S.
    Hussain, Abid
    Baig, M. A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2013, 88 : 198 - 202
  • [7] SYNTHESIZE OF GOLD NANOPARTICLES WITH 532 NM AND 1064 NM PULSE LASER ABLATION
    Shukri, W. Norsyuhada W.
    Bidin, Noriah
    Affandi, Syafiq
    Bohari, Siti Pauliena
    JURNAL TEKNOLOGI, 2016, 78 (03): : 267 - 270
  • [8] Surface modifications of a titanium implant by a picosecond Nd:YAG laser operating at 1064 and 532 nm
    Trtica, Milan
    Gakovic, Biljana
    Batani, Dimitri
    Desai, Tara
    Panjan, Peter
    Radak, Bojan
    APPLIED SURFACE SCIENCE, 2006, 253 (05) : 2551 - 2556
  • [9] Study on laser anti-damage film of 532nm and 1064nm Nd:YAG laser
    Tang, Ji-long
    Liu, Guo-jun
    Fu, Xiu-hua
    Zhao, Ying-jie
    Wang, Jing
    ADVANCED OPTICAL MANUFACTURING TECHNOLOGIES, PTS 1 AND 2, 2007, 6722
  • [10] COMBINED 1064 nm AND 532 nm FRACTIONAL PICOSECOND LASER TREATMENT OF FACIAL WRINKLES
    Gold, Michael
    Thompson, Brynne
    LASERS IN SURGERY AND MEDICINE, 2017, 49 : 13 - 13