Wind loads on industrial solar panel arrays and supporting roof structure

被引:76
|
作者
Wood, GS [1 ]
Denoon, RO
Kwok, KCS
机构
[1] Univ Sydney, Dept Civil Engn, Sydney, NSW 2006, Australia
[2] Ove Arup & Partners, Kowloon, Hong Kong, Peoples R China
关键词
solar panels; wind loading; wind tunnel testing; pressure measurements;
D O I
10.12989/was.2001.4.6.481
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Wind tunnel pressure tests were conducted on a 1:100 scale model of a large industrial building with solar panels mounted parallel to the flat roof. The model form was chosen to have the same aspect ratio as the Texas Tech University test building. Pressures were simultaneously measured on the roof, and on the topside and underside of the solar panel, the latter two combining to produce a nett panel pressure. For the configurations tested, varying both the lateral spacing between the panels and the height of the panels above the roof surface had little influence on the measured pressures, except at the leading edge. The orientation of the panels with respect to the wind flow and the proximity of the panels to the leading edge had a greater effect on the measured pressure distributions. The pressure coefficients are compared against the results for the roof with no panels attached. The model results with no panels attached agreed well with full-scale results from the Texas Tech test building.
引用
收藏
页码:481 / 494
页数:14
相关论文
共 50 条
  • [1] Experimental Investigation of Wind Loads on Roof-Mounted Solar Arrays
    Yao, Jianfeng
    Tu, Zhibin
    Wang, Dong
    Shen, Guohui
    Lou, Wenjuan
    SUSTAINABILITY, 2022, 14 (14)
  • [2] Aerodynamic mechanisms for wind loads on tilted, roof-mounted, solar arrays
    Kopp, Gregory A.
    Farquhar, Steve
    Morrison, Murray J.
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2012, 111 : 40 - 52
  • [3] Influence of solar panel arrays on the wind loading of industrial roofs
    Wood, GS
    Denoon, RO
    Kwok, KCS
    Eddy, BJ
    Worrall, SJ
    FIRST INTERNATIONAL SYMPOSIUM ON WIND AND STRUCTURES FOR THE 21ST CENTURY, 2000, : 195 - 204
  • [4] Effects of building parameters on wind loads on flat-roof-mounted solar arrays
    Wang, Jingxue
    Yang, Qingshan
    Tamura, Yukio
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2018, 174 : 210 - 224
  • [5] NUMERICAL STUDY OF WIND LOADS ON RESIDENTIAL ROOF-MOUNTED SOLAR PHOTOVOLTAIC ARRAYS
    Giorges, Aklilu T. G.
    Amador, Guillermo J.
    Goodman, Joseph
    ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2014, VOL 6B, 2015,
  • [6] Wind loads for designing ground-mounted solar-panel arrays
    Ginger, J. D.
    Bodhinayake, G. G.
    Ingham, S.
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2019, 20 (03) : 204 - 218
  • [7] Use of the Wind Tunnel Test Method for Obtaining Design Wind Loads on Roof-Mounted Solar Arrays
    Kopp, Gregory A.
    Banks, David
    JOURNAL OF STRUCTURAL ENGINEERING, 2013, 139 (02) : 284 - 287
  • [8] Investigation into the effect of rounded building corner on wind loads of flat-roof-mounted solar arrays
    Dai, S. F.
    Liu, H. J.
    Peng, H. Y.
    JOURNAL OF BUILDING ENGINEERING, 2024, 87
  • [9] Wind loads on a solar PV panel with side plates
    Chung, K. M
    Chou, C. C
    Chung, C. Y
    Journal of Mechanics, 2021, 37 : 253 - 259
  • [10] Wind Loads on a Solar Panel at High Tilt Angles
    Chou, Chin-Cheng
    Chung, Ping-Han
    Yang, Ray-Yeng
    APPLIED SCIENCES-BASEL, 2019, 9 (08):