Experimental investigation of free convection in roof solar collector

被引:28
|
作者
Khedari, J [1 ]
Yimsamerjit, P [1 ]
Hirunlabh, J [1 ]
机构
[1] King Mongkuts Univ Technol Thonburi, Sch Energy & Mat, Bldg Sci Res Ctr, Bangkok 10140, Thailand
关键词
free convection; open-ended inclined rectangular channel; data correlation;
D O I
10.1016/S0360-1323(01)00054-3
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A test set-Lip was developed for determining the internal convective heat transfer coefficient and the induced air flowrate of a roof solar collector. The set-up was composed of an open-ended inclined rectangular channel. The tilt angle and air gap of channel were fixed at 30degrees and 140 mm, respectively. The inner channel width and length were 680 and 1360 mm, respectively. The upper plate was maintained at a uniform temperature and tests were carried out for a wide range of temperature varying between 40degreesC and 75 degreesC. Data analysis were made to develop Nusselt and Reynolds number correlations as a function of Rayleigh number and aspect ratio (gap/length). The equations could be used for deter-mining the mean convection heat transfer coefficient and the induced air flowrate of the roof solar collectors and a wide range of convective heat exchangers of similar geometry as well. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:455 / 459
页数:5
相关论文
共 50 条
  • [1] Experimental study of natural convection in PV roof solar collector
    Phiraphat, Sahachai
    Prommas, Ratthasak
    Puangsombut, Withaya
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2017, 89 : 31 - 38
  • [2] Experimental investigation on generated power of thermoelectric roof solar collector
    Maneewan, S
    Khedari, J
    Zeghmati, B
    Hirunlabh, J
    Eakburanawat, J
    TWENTY-SECOND INTERNATIONAL CONFERENCE ON THERMOELECTRICS, PROCEEDINGS ICT '03, 2003, : 574 - 577
  • [3] Investigation on generated power of thermoelectric roof solar collector
    Maneewan, S
    Khedari, J
    Zeghmati, B
    Hirunlabh, J
    Eakburanawat, J
    RENEWABLE ENERGY, 2004, 29 (05) : 743 - 752
  • [4] Transfer calculation in a free convection air solar collector
    Rodono, G
    Volpes, R
    ENERGY AND BUILDINGS, 1998, 27 (01) : 21 - 27
  • [5] An Experimental Investigation of Ribbed Solar Air Heater-Free Convection
    Kumar, Niraj
    Singh, Manoj Kumar
    Yadav, Vinod Singh
    Singh, Vineet
    Maheswari, Anurag
    RECENT ADVANCES IN INDUSTRIAL PRODUCTION, ICEM 2020, 2022, : 373 - 381
  • [6] Experimental investigation and analysis of the hybrid solar collector
    Devaraj, R.
    Ramachandran, S.
    Mageshwaran, G.
    Gobinath, K.
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2018, 39 (03) : 211 - 216
  • [7] EXPERIMENTAL INVESTIGATION OF VACUUM TUBE SOLAR COLLECTOR
    Wadaskar, N. N.
    Karale, S. R.
    2009 SECOND INTERNATIONAL CONFERENCE ON EMERGING TRENDS IN ENGINEERING AND TECHNOLOGY (ICETET 2009), 2009, : 842 - +
  • [8] Free convection heat losses in a flat plate solar collector
    Lenic, Kristian
    Frankovic, Bernard
    Energy and the Environment 2002, Vol I, 2002, : 101 - 114
  • [9] Experimental investigation and analysis of the hybrid solar collector
    Ramachandran, S. (aishram2006@gmail.com), 1600, Taylor and Francis Ltd. (39):
  • [10] Experimental investigation of modified solar still integrated with solar collector
    Alwan, Naseer T.
    Shcheklein, S. E.
    Ali, Obed M.
    CASE STUDIES IN THERMAL ENGINEERING, 2020, 19