Quantitative analysis and qualitative performance of fiat-panel detector for digital mammography

被引:0
|
作者
Debrie, A [1 ]
Caron, M [1 ]
Savard, S [1 ]
Hansroul, M [1 ]
Wong, K [1 ]
Loustauneau, V [1 ]
Shukri, Z [1 ]
Martin, JP [1 ]
机构
[1] ANRAD Corp, St Laurent, PQ, Canada
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
引用
收藏
页码:25 / 31
页数:7
相关论文
共 50 条
  • [1] Quantitative analysis of performance of selenium flat-panel detector for interventional mammography
    Debrie, A
    Polischuk, B
    Rougeot, H
    Hansroul, M
    Poliquin, É
    Caron, M
    Wong, K
    Shukri, Z
    Martin, JP
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 176 - 184
  • [2] High-performance dual-energy imaging with a fiat-panel detector: Answering the challenge of dual-KVp flood-field correction
    Dhanantwari, A.
    Siewerdsen, J.
    Shkumat, N.
    Williams, D.
    Richard, S.
    Daly, M.
    Paul, N.
    Moseley, D.
    Jaffray, D.
    Yorkston, J.
    VanMetter, R.
    MEDICAL PHYSICS, 2006, 33 (06) : 2252 - 2252
  • [3] Simulation of image performance of CZT detector for digital mammography
    Alsager, Abdulaziz A.
    Spyrou, Nicholas M.
    EUROCON 2007: THE INTERNATIONAL CONFERENCE ON COMPUTER AS A TOOL, VOLS 1-6, 2007, : 1478 - 1483
  • [4] Digital mammography: Performance considerations and current detector designs
    Williams, MB
    Fajardo, LL
    ACADEMIC RADIOLOGY, 1996, 3 (05) : 429 - 437
  • [5] Imaging performance of a clinical selenium flat-panel detector for advanced applications in full-field digital mammography
    Loustauneau, V
    Bissonnette, M
    Cadieux, S
    Hansroul, A
    Masson, E
    Savard, S
    Polischuk, B
    Lehtimäki, M
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 1010 - 1020
  • [6] Characterization of a direct, full-field flat-panel digital mammography detector
    Zhao, B
    Zhao, W
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 157 - 167
  • [7] Analysis of the detective quantum efficiency of a developmental detector for digital mammography
    Williams, MB
    Simoni, PU
    Smilowitz, L
    Stanton, M
    Phillips, W
    Stewart, A
    MEDICAL PHYSICS, 1999, 26 (11) : 2273 - 2285
  • [8] Performance evaluation of a retrofit digital detector-based mammography system
    Marshall, Nicholas W.
    van Ongeval, Chantal
    Bosmans, Hilde
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 312 - 322
  • [9] Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: Characterization of a small area prototype detector
    Zhao, W
    Ji, WG
    Debrie, A
    Rowlands, JA
    MEDICAL PHYSICS, 2003, 30 (02) : 254 - 263
  • [10] Radiation exposure in full-field digital mammography with a selenium flat-panel detector
    Gosch, D.
    Jendrass, S.
    Scholz, M.
    Kahn, T.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2006, 178 (07): : 693 - 697