High-resolution soft X-ray spectrometry using the Electron-Multiplying Charge-Coupled Device (EM-CCD)

被引:1
|
作者
Hall, David J. [1 ]
Tutt, James H. [1 ]
Soman, Matthew R. [1 ]
Holland, Andrew D. [1 ]
Murray, Neil J. [1 ]
Schmitt, Bernd [2 ]
Schmitt, Thorsten [2 ]
机构
[1] Open Univ, Ctr Elect Imaging e2v, DPS, Milton Keynes MK7 6AA, Bucks, England
[2] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
关键词
CCD; EM-CCD; soft X-ray; spectrometer; IXO; RIXS; NOISE PERFORMANCE;
D O I
10.1117/12.2024010
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The Electron-Multiplying Charge-Coupled Device (EM-CCD) shares a similar structure to the CCD except for the inclusion of a gain register that multiplies signal before the addition of read-noise, offering sub-electron effective read-noise at high frame-rates. EM-CCDs were proposed for the dispersive spectrometer on the International X-ray Observatory (IXO) to bring sub-300 eV X-rays above the noise, increasing the science yield. The high-speed, low-noise performance of the EMC-CD brought added advantages of reduced dark current and stray-light per frame, reducing cooling and filtering requirements. To increase grating efficiency, several diffracted spectral orders were co-located so the inherent energy resolution of the detector was required for order separation. Although the spectral resolution of the EM-CCD is degraded by the gain process, it was shown that the EM-CCD could achieve the required separation. The RIXS spectrometer at the Advanced Resonant Spectroscopy beamline (ADRESS) of the Swiss Light Source (SLS) at the Paul Scherrer Institute currently uses a CCD, with charge spreading between pixels limiting the spatial resolution to 24 mu m (FWHM). Through improving the spatial resolution below 5 mu m alongside upgrading the grating, a factor of two energy resolution improvement could theoretically be made. With the high-speed, low-noise performance of the EM-CCD, photon-counting modes could allow the use of centroiding techniques to improve the resolution. Using various centroiding techniques, a spatial resolution of 2 mu m (FWHM) has been achieved experimentally, demonstrating the benefits of this detector technology for soft X-ray spectrometry. This paper summarises the use of EM-CCDs from our first investigations for IXO through to our latest developments in ground-based testing for synchrotron-research and looks beyond to future possibilities.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Improving the spatial resolution of soft X-ray detection using an Electron-Multiplying Charge-Coupled Device
    Soman, M. R.
    Hall, D. J.
    Tutt, J. H.
    Murray, N. J.
    Holland, A. D.
    Schmitt, T.
    Raabe, J.
    Schmitt, B.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [2] Developing a high-resolution X-ray imager using Electron-Multiplying (EM) CCDs
    Tutt, James H.
    Hall, David J.
    Holland, Andrew D.
    Murray, Neil J.
    Endicott, James
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XV, 2013, 8852
  • [3] The Noise Performance of Electron-Multiplying Charge-Coupled Devices at Soft X-Ray Energy Values
    Tutt, James H.
    Holland, Andrew D.
    Murray, Neil J.
    Hall, David J.
    Harriss, Richard D.
    Clarke, Andrew
    Evagora, Anthony M.
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2012, 59 (08) : 2192 - 2198
  • [4] The Noise Performance of Electron-Multiplying Charge-Coupled Devices at X-ray Energies
    Tutt, James H.
    Holland, Andrew D.
    Hall, David J.
    Harriss, Richard D.
    Murray, Neil J.
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2012, 59 (01) : 167 - 175
  • [5] Electron-multiplying - CCD camera in x-ray Imaging
    Kuhls-Gilcrist, Andrew
    Rudin, Stephen
    PHOTONICS SPECTRA, 2007, 41 (08) : 52 - 53
  • [6] Localization accuracy in single molecule microscopy using electron-multiplying charge-coupled device cameras
    Chao, Jerry
    Ward, E. Sally
    Ober, Raimund J.
    THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING XIX, 2012, 8227
  • [7] Electron-multiplying CCDs for future soft X-ray spectrometers
    Tutt, J. H.
    Holland, A. D.
    Murray, N. J.
    Harriss, R. D.
    Hall, D. J.
    Soman, M.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [8] Reconstruction algorithm of low-light integral imaging by electron-multiplying charge-coupled device
    Chen, Yuanjin
    Zou, Yan
    Huang, Pengwei
    Qi, Jiajia
    He, Weiji
    Chen, Qian
    OPTICAL ENGINEERING, 2019, 58 (05)
  • [9] Two approximations for the geometric model of signal amplification in an electron-multiplying charge-coupled device detector
    Chao, Jerry
    Ram, Sripad
    Ward, E. Sally
    Ober, Raimund J.
    THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING XX, 2013, 8589
  • [10] Soft X-ray performance of an optimised charge-coupled device for astronomy
    Buggey, T. W.
    Randall, G.
    Parsons, S.
    Jones, L. S.
    Decaire, A. L.
    Arnold, T.
    Hetherington, O.
    Holland, A. D.
    Hall, D. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1066