Anatomical total shoulder arthroplasty in young patients with osteoarthritis ALL-POLYETHYLENE VERSUS METAL-BACKED GLENOID

被引:30
|
作者
Gauci, M. O. [1 ,2 ]
Bonnevialle, N. [3 ]
Moineau, G. [4 ]
Baba, M. [5 ]
Walch, G. [6 ]
Boileau, P. [1 ,2 ]
机构
[1] Hop Pasteur 2, Inst Univ Locomoteur & Sport, Nice 1, France
[2] Univ Nice Sophia Antipolis, Nice 1, France
[3] CHU Toulouse Purpan, Toulouse, France
[4] Clin Pasteur Lanroze, Brest, France
[5] Sydney Adventist Hosp, Wahroonga, NSW, Australia
[6] Ctr Med Santy, Lyon, France
来源
BONE & JOINT JOURNAL | 2018年 / 100B卷 / 04期
关键词
PRIMARY GLENOHUMERAL OSTEOARTHRITIS; MIDDLE-AGED PATIENTS; FOLLOW-UP; COMPONENT; OUTCOMES; HEMIARTHROPLASTY; MULTICENTER; REPLACEMENT; CONVERSION; ARTHRITIS;
D O I
10.1302/0301-620X.100B4.BJJ-2017-0495.R2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims Controversy about the use of an anatomical total shoulder arthroplasty (aTSA) in young arthritic patients relates to which is the ideal form of fixation for the glenoid component: cemented or cementless. This study aimed to evaluate implant survival of aTSA when used in patients aged < 60 years with primary glenohumeral osteoarthritis (OA), and to compare the survival of cemented all-polyethylene and cementless metal-backed glenoid components. Materials and Methods A total of 69 consecutive aTSAs were performed in 67 patients aged < 60 years with primary glenohumeral OA. Their mean age at the time of surgery was 54 years (35 to 60). Of these aTSAs, 46 were undertaken using a cemented polyethylene component and 23 were undertaken using a cementless metal-backed component. The age, gender, preoperative function, mobility, premorbid glenoid erosion, and length of follow-up were comparable in the two groups. The patients were reviewed clinically and radiographically at a mean of 10.3 years (5 to 12, SD 26) postoperatively. Kaplan-Meier survivorship analysis was performed with revision as the endpoint. Results A total of 26 shoulders (38%) underwent revision surgery: ten (22%) in the polyethylene group and 16 (70%) in the metal-backed group (p < 0.0001). At 12 years' follow-up, the rate of implant survival was 74% (SD 0.09) for polyethylene components and 24% (SD 0.10) for metal-backed components (p < 0.0002). Glenoid loosening or failure was the indication for revision in the polyethylene group, whereas polyethylene wear with metal-on-metal contact, instability, and insufficiency of the rotator cuff were the indications for revision in the metal-backed group. Preoperative posterior subluxation of the humeral head with a biconcave/retroverted glenoid (Walch B2) had an adverse effect on the survival of a metal-backed component. Conclusion The survival of a cemented polyethylene glenoid component is three times higher than that of a cementless metal-backed glenoid component ten years after aTSA in patients aged < 60 years with primary glenohumeral OA. Patients with a biconcave (B2) glenoid have the highest risk of failure.
引用
收藏
页码:485 / 492
页数:8
相关论文
共 50 条
  • [1] Glenoid failure after total shoulder arthroplasty with cemented all-polyethylene versus metal-backed implants: a systematic review protocol
    Zan, Renato Aroca Aroca
    Lazarini, Rafael Fuchs
    Matsunaga, Fabio Teruo
    Netto, Nicola Archetti
    Belloti, Joao Carlos
    Tamaoki, Marcel Jun Sugawara
    BMJ OPEN, 2020, 10 (12):
  • [2] All-Polyethylene versus Metal-Backed Tibial Components in Total Knee Arthroplasty
    AbuMoussa, Samuel
    White, Charles Cody
    Eichinger, Josef K.
    Friedman, Richard J.
    JOURNAL OF KNEE SURGERY, 2019, 32 (08) : 714 - 718
  • [3] All-polyethylene versus metal-backed tibial component in total knee arthroplasty
    Longo, Umile Giuseppe
    Ciuffreda, Mauro
    D'Andrea, Valerio
    Mannering, Nicholas
    Locher, Joel
    Denaro, Vincenzo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (11) : 3620 - 3636
  • [4] All-polyethylene versus metal-backed tibial component in total knee arthroplasty
    Umile Giuseppe Longo
    Mauro Ciuffreda
    Valerio D’Andrea
    Nicholas Mannering
    Joel Locher
    Vincenzo Denaro
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 3620 - 3636
  • [5] The case for the metal-backed glenoid design in total anatomical shoulder arthroplasty
    Katz, Denis C.
    Sauzieres, P.
    Valenti, P.
    Kany, J.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2012, 22 (01): : 9 - 16
  • [6] The case for the metal-backed glenoid design in total anatomical shoulder arthroplasty
    Denis C. Katz
    P. Sauzières
    P. Valenti
    J. Kany
    European Journal of Orthopaedic Surgery & Traumatology, 2012, 22 : 9 - 16
  • [7] Can convertible metal-backed glenoid components replace cemented polyethylene glenoid components in anatomical total shoulder arthroplasty?
    Myung-Sun Kim
    Yeong-Seub Ahn
    Sun-Ho Lee
    Hyeon Jang Jeong
    Young Kyu Kim
    Joo Han Oh
    BMC Surgery, 23
  • [8] Can convertible metal-backed glenoid components replace cemented polyethylene glenoid components in anatomical total shoulder arthroplasty?
    Kim, Myung-Sun
    Ahn, Yeong-Seub
    Lee, Sun-Ho
    Jeong, Hyeon Jang
    Kim, Young Kyu
    Oh, Joo Han
    BMC SURGERY, 2023, 23 (01)
  • [9] Loosening and revision rates after total shoulder arthroplasty: a systematic review of cemented all-polyethylene glenoid and three modern designs of metal-backed glenoid
    Dong Min Kim
    Mohammed Aldeghaither
    Fahad Alabdullatif
    Myung Jin Shin
    Erica Kholinne
    Hyojune Kim
    In-Ho Jeon
    Kyoung-Hwan Koh
    BMC Musculoskeletal Disorders, 21
  • [10] Loosening and revision rates after total shoulder arthroplasty: a systematic review of cemented all-polyethylene glenoid and three modern designs of metal-backed glenoid
    Kim, Dong Min
    Aldeghaither, Mohammed
    Alabdullatif, Fahad
    Shin, Myung Jin
    Kholinne, Erica
    Kim, Hyojune
    Jeon, In-Ho
    Koh, Kyoung-Hwan
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)