Oscillometric Blood Pressure Monitor Modeling

被引:3
|
作者
Pinheiro, Eduardo C. [1 ]
机构
[1] Setubals Super Sch Technol, P-2650761 Setubal, Portugal
关键词
Biomedical transducers; Identification; Modeling; Nonlinear systems;
D O I
10.1109/IEMBS.2008.4649150
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Oscillometric blood pressure monitors are fairly reliable medical equipments, inexpensive and widely used both in domicile and clinical measurements of blood pressure, however they have not yet been subject of deep investigation. The research reported in this paper presents the development of an analytical model of an oscillometric blood pressure monitor, a task which has not been dealt with and is useful in order to improve these devices' accuracy limitations. The approach taken was to divide the transducer in two distinct components, the electromechanical and the pneumatic, considering compression and decompression phases. Differential equations were derived, using electric and mechanical principles, to explain the equipment's behavior during the air-pump compression, and the pressure evolution during decompression was identified by exponential approximation. This comprehensive study obtained several non-ideal and nonlinear dynamics, and describes some of the possible simplifications to the models used.
引用
收藏
页码:303 / 306
页数:4
相关论文
共 50 条
  • [1] COMPARATIVE ACCURACIES OF A FINGER BLOOD-PRESSURE MONITOR AND AN OSCILLOMETRIC BLOOD-PRESSURE MONITOR
    EPSTEIN, RH
    HUFFNAGLE, S
    BARTKOWSKI, RR
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (02): : 161 - 167
  • [2] Multiple Models Oscillometric Blood Pressure Monitor Identification
    Pinheiro, Eduardo C.
    2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-8, 2008, : 319 - 322
  • [3] Estimation of central systolic blood pressure using an oscillometric blood pressure monitor
    Cheng, Hao-Min
    Wang, Kang-Ling
    Chen, Ying-Hwa
    Lin, Shing-Jong
    Chen, Lung-Ching
    Sung, Shih-Hsien
    Ding, Philip Yu-An
    Yu, Wen-Chung
    Chen, Jaw-Wen
    Chen, Chen-Huan
    HYPERTENSION RESEARCH, 2010, 33 (06) : 592 - 599
  • [4] Accuracy of an oscillometric blood pressure monitor in anesthetized pigs
    Reed, Rachel
    Barletta, Michele
    Grimes, Janet
    Mumaw, Jennifer
    Park, Hea Jin
    Giguere, Steeve
    Azain, Michael
    Fang, Xi
    Quandt, Jane
    LABORATORY ANIMALS, 2018, 52 (05) : 490 - 496
  • [5] Estimation of central systolic blood pressure using an oscillometric blood pressure monitor
    Hao-Min Cheng
    Kang-Ling Wang
    Ying-Hwa Chen
    Shing-Jong Lin
    Lung-Ching Chen
    Shih-Hsien Sung
    Philip Yu-An Ding
    Wen-Chung Yu
    Jaw-Wen Chen
    Chen-Huan Chen
    Hypertension Research, 2010, 33 : 592 - 599
  • [6] Accurate Estimation of Central Systolic Blood Pressure Using an Oscillometric Blood Pressure Monitor
    Cheng, Hao-Min
    Wang, Kang-Lin
    Chen, Ying-Hwa
    Lin, Shing-Jong
    Chen, Lung-Ching
    Sung, Shih-Hsien
    Lee, Wen-Shin
    Ding, Philip Yu-An
    Yu, Wen-Chung
    Chen, Jaw-Wen
    Chen, Chen-Huan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A462 - A463
  • [7] A clinical evaluation of an oscillometric blood pressure monitor on anesthetized horses
    Branson, KR
    JOURNAL OF EQUINE VETERINARY SCIENCE, 1997, 17 (10) : 537 - 540
  • [8] Evaluation of an oscillometric blood pressure monitor for use in anesthetized cats
    Pedersen, KM
    Butler, MA
    Ersboll, AK
    Pedersen, HD
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2002, 221 (05) : 646 - 650
  • [9] Evaluation of an oscillometric blood pressure monitor for use in anesthetized sheep
    Trim, Cynthia M.
    Hofmeister, Erik H.
    Peroni, John F.
    Thoresen, Merrilee
    VETERINARY ANAESTHESIA AND ANALGESIA, 2013, 40 (06) : E31 - E39
  • [10] The oscillometric blood pressure measurement - mathematical modeling
    Juroszek, Barbara
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (12): : 304 - 307