A Fiber Bragg Grating Sensor for Radial Artery Pulse Waveform Measurement

被引:54
|
作者
Jia, Dagong [1 ]
Chao, Jing [1 ]
Li, Shuai [1 ]
Zhang, Hongxia [1 ]
Yan, Yingzhan [2 ]
Liu, Tiegen [1 ]
Sun, Ye [3 ,4 ]
机构
[1] Tianjin Univ, Key Lab Optoelect Informat Technol, Minist Educ, Coll Precis Instruments & Optoelect Engn, Tianjin 300072, Peoples R China
[2] China Elect Technol Grp Corp, Res Inst 54, Beijing, Peoples R China
[3] Michigan Technol Univ, Dept Mech Engn Engn Mech, Houghton, MI 49931 USA
[4] Michigan Technol Univ, Dept Biomed Engn, Houghton, MI 49931 USA
基金
中国国家自然科学基金;
关键词
Fiber Bragg grating (FBG); lever amplification mechanism; radial artery pulse waveform; TRADITIONAL CHINESE MEDICINE; AORTIC PRESSURE; SYSTEM; DIAGNOSIS;
D O I
10.1109/TBME.2017.2722008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, we report the design and experimental validation of a novel optical sensor for radial artery pulse measurement based on fiber Bragg grating (FBG) and lever amplification mechanism. Pulse waveform analysis is a diagnostic tool for clinical examination and disease diagnosis. High fidelity radial artery pulse waveform has been investigated in clinical studies for estimating central aortic pressure, which is proved to be predictors of cardiovascular diseases. As a three-dimensional cylinder, the radial artery needs to be examined from different locations to achieve optimal pulse waveform for estimation and diagnosis. The proposed optical sensing system is featured as high sensitivity and immunity to electromagnetic interference for multilocation radial artery pulse waveform measurement. The FBG sensor can achieve the sensitivity of 8.236 nm/N, which is comparable to a commonly used electrical sensor. This FBG-based system can provide high accurate measurement, and the key characteristic parameters can be then extracted from the raw signals for clinical applications. The detecting performance is validated through experiments guided by physicians. In the experimental validation, we applied this sensor tomeasure the pulse waveforms at various positions and depths of the radial artery in the wrist according to the diagnostic requirements. The results demonstrate the high feasibility of using optical systems for physiological measurement and using this FBG sensor for radial artery pulse waveform in clinical applications.
引用
收藏
页码:839 / 846
页数:8
相关论文
共 50 条
  • [1] Development of a Hybrid Force-Displacement Sensor Based on Fiber Bragg Grating for Radial Artery Pulse Waveform Measurement
    Tang, Zhongxin
    Wang, Shuxin
    Shi, Chaoyang
    IEEE SENSORS JOURNAL, 2021, 21 (18) : 20045 - 20054
  • [2] Radial arterial compliance measurement by fiber Bragg grating pulse recorder
    U Sharath
    C Shwetha
    K Anand
    S Asokan
    Journal of Human Hypertension, 2014, 28 : 736 - 742
  • [3] Radial arterial compliance measurement by fiber Bragg grating pulse recorder
    Sharath, U.
    Shwetha, C.
    Anand, K.
    Asokan, S.
    JOURNAL OF HUMAN HYPERTENSION, 2014, 28 (12) : 736 - 742
  • [4] Fiber Bragg Grating Sensor for Humidity Measurement
    Aris, A. M.
    Irawati, N.
    Rahman, H. A.
    Harun, S. W.
    Ahad, I. Z. M.
    2015 5TH IEEE INTERNATIONAL CONFERENCE ON SYSTEM ENGINEERING AND TECHNOLOGY (ICSET), 2015, : 55 - 59
  • [5] Modified Fiber Bragg grating pulse pressure sensor
    Kaczmarek, Tomasz
    Kaczmarek, Zdzislaw
    LIGHTGUIDES AND THEIR APPLICATIONS III, 2007, 6608
  • [6] Simultaneous Measurement of Local Pulse Wave Velocities in Radial Arteries Using a Soft Sensor Based on the Fiber Bragg Grating Technique
    Wang, Jing
    Wang, Zhukun
    Zhang, Zijun
    Li, Peiyun
    Pan, Han
    Ren, Yong
    Hou, Tuo
    Wang, Chengbo
    Kwong, Chiew-Foong
    Zhang, Bei
    Yang, Sen
    Bie, Jing
    MICROMACHINES, 2024, 15 (04)
  • [7] Carotid Arterial Pulse Waveform Measurements Using Fiber Bragg Grating Pulse Probe
    Padma, Srivani
    Umesh, Sharath
    Srinivas, Talabattula
    Asokan, Sundarrajan
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2018, 22 (05) : 1415 - 1420
  • [8] Fiber Bragg grating sensor for the measurement of elevated temperature
    Zhang, YG
    Xiang, SQ
    He, H
    Zhu, R
    Wang, XZ
    Advanced Sensor Systems and Applications II Pt 1and 2, 2004, 5634 : 62 - 67
  • [9] Fiber Bragg grating sensor for magentic field measurement
    Ma, Rui
    Zhang, Wentao
    Wang, Zhaogang
    Huang, Wenzhu
    Li, Fang
    Li, Dongmei
    2017 IEEE SENSORS, 2017, : 307 - 309
  • [10] Characterization of Fiber Bragg Grating Sensor for pH Measurement
    Yulianti, Ian
    Supa'at, Abu Sahmah M.
    Idrus, Sevia M.
    2014 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2014, : 1163 - 1166