Dual-Functional Dynamic Voltage Restorer to Limit Fault Current

被引:56
|
作者
Jiang, Fei [1 ]
Tu, Chunming [2 ]
Guo, Qi [2 ]
Shuai, Zhikang [2 ]
He, Xi [2 ]
He, Jiao [1 ]
机构
[1] Changsha Univ Sci & Technol, Sch Elect & Informat Engn, Changsha 410004, Hunan, Peoples R China
[2] Hunan Univ, Coll Elect & Informat Engn, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Bridge-type fault current limiter; dual-functional; dynamic voltage restorer (DVR); COMPENSATION; FCL;
D O I
10.1109/TIE.2018.2868254
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper proposes a dual-function dynamic voltage restorer (DFDVR) with fault current-limiting capability. The new topology can operate under different modes: the short-circuit fault current-limiting mode and the compensation mode for voltage fluctuation. Different functions of the DFDVR are achieved by controlling a brake chopper circuit and antiparallel thyristors. During fault conditions, the antiparallel thyristors are deactivated to protect the dc-side capacitor, and the duration of the ON-and OFF-periods of the semiconductor switch in the brake chopper circuit is controlled to adjust fault current amplitudes. During voltage sags, the antiparallel thyristors are activated, and the brake chopper circuit is turned OFF by controlling the gate turn-OFF thyristor in the brake chopper circuit, thus making the DFDVR similar to a conventional DVR. The control scheme and optimal parameter selection of the DFDVR are provided. The design methodology of the DFDVR was verified through simulations performed using the PSCAD/EMTDC software. The experimental results prove the capability and effectiveness of the DFDVR topology.
引用
收藏
页码:5300 / 5309
页数:10
相关论文
共 50 条
  • [1] Coordination of Dual-functional Dynamic Voltage Restorer and Recloser in Power Distribution System
    Jiang, Fei
    Chen, Lei
    Tu, Chunming
    Cheng, Siju
    Zhu, Rongwu
    Liserre, Marco
    2019 IEEE 13TH INTERNATIONAL CONFERENCE ON COMPATIBILITY, POWER ELECTRONICS AND POWER ENGINEERING (CPE-POWERENG), 2019,
  • [2] Fault Current Interruption by the Dynamic Voltage Restorer
    Ajaei, Firouz Badrkhani
    Farhangi, Shahrokh
    Iravani, Reza
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (02) : 903 - 910
  • [3] Fault Current Interruption by the Dynamic Voltage Restorer
    Ajaei, Firouz Badrkhani
    Farhangi, Shahrokh
    Iravani, Reza
    2013 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PES), 2013,
  • [4] A dual-functional medium voltage level DVR to limit downstream fault currents
    Li, Yun Wei
    Vilathgamuwa, D. Mahinda
    Loh, Poh Chiang
    Blaabjerg, Frede
    2006 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-7, 2006, : 1326 - +
  • [5] A conventional dynamic voltage restorer with fault current limiting capability
    Nourmohamadi, Hesam
    Bektas, Senol I.
    Hosseini, Seyed Hossein
    Babaei, Ebrahim
    Sabahi, Mehran
    9TH INTERNATIONAL CONFERENCE ON THEORY AND APPLICATION OF SOFT COMPUTING, COMPUTING WITH WORDS AND PERCEPTION, ICSCCW 2017, 2017, 120 : 750 - 757
  • [6] Comparison of Fault Current Limitation with Saturable Reactor and Dynamic Voltage Restorer
    Khan, Rabia
    Mehrizi-Sani, Ali
    2017 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2017,
  • [7] Design Considerations of a Fault Current Limiting Dynamic Voltage Restorer (FCL-DVR)
    Shuai, Zhikang
    Yao, Peng
    Shen, Z. J.
    Tu, Chunming
    Jiang, Fei
    Cheng, Ying
    IEEE TRANSACTIONS ON SMART GRID, 2015, 6 (01) : 14 - 25
  • [8] Design Consideration of a Dual-Functional Bridge-Type Fault Current Limiter
    Jiang, Fei
    Cheng, Siju
    Tu, Chunming
    Guo, Qi
    Zhu, Rongwu
    Li, Xiaoyun
    Liserre, Marco
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2020, 8 (04) : 3825 - 3834
  • [9] Analysis and control of bridge-type fault current limiter integrated with the dynamic voltage restorer
    Tu, Chunming
    Guo, Qi
    Jiang, Fei
    Shuai, Zhikang
    He, Xi
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 95 : 315 - 326
  • [10] Fault Current Limiter Dynamic Voltage Restorer (FCL-DVR) With Reduced Number of Components
    Ghavidel, Pedram
    Farhadi, Masoud
    Dabbaghjamanesh, Morteza
    Jolfaei, Alireza
    Sabahi, Mehran
    Ghavidel, Pedram (p.ghavidel93@ms.tabrizu.ac.ir), 1600, Institute of Electrical and Electronics Engineers Inc. (02): : 526 - 534