Equipment-Free Detection of K+ on Microfluidic Paper-Based Analytical Devices Based on Exhaustive Replacement with Ionic Dye in Ion-selective Capillary Sensors

被引:60
|
作者
Soda, Yoshiki [1 ]
Citterio, Daniel [2 ]
Bakker, Eric [1 ]
机构
[1] Univ Geneva, Dept Inorgan, Analyt Chem, Quai Ernest Ansermet 30, CH-1211 Geneva, Switzerland
[2] Keio Univ, Dept Appl Chem, Kohoku Ku, 3-14-1 Hiyoshi, Yokohama, Kanagawa 2238522, Japan
基金
瑞士国家科学基金会;
关键词
paper-based analytical devices; capillary sensor; ion-selective membrane; potassium detection; serum measurement; SOLVATOCHROMIC DYES; PATTERNED PAPER; SERUM VISCOSITY; SODIUM; POTASSIUM; BULK; ACID; PH; ELECTRODES; PLATFORM;
D O I
10.1021/acssensors.8b01521
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A distance-based analysis of potassium ion (K+) is introduced that is performed on a microfluidic paper-based analytical device (mu PAD) coupled to an ion-selective capillary sensor. The concept is based on two sequential steps, the selective replacement of analyte ion with an ionic dye, and the detection of this dye in a distance-based readout on paper. To achieve the first step, the capillary sensor holds a poly(vinyl chloride) (PVC) membrane film layer plasticized by dioctyl sebacate (DOS) that contains the potassium ionophore valinomycin, a lipophilic cation-exchanger and the ionic indicator Thioflavin T (ThT) on its inner wall. Upon introduction of the sample, K+ in the aqueous sample solution is quantitatively extracted into the film membrane and replaced with ThT. To convert the ion exchange signal into a distance-based analysis, this solution was dropped onto the inlet area of a mu PAD to flow the ThT along a channel defined by wax printing, resulting in the electrostatic binding of ThT to the cellulose carboxylic groups. The initial amount of K+ determines the amount of ThT in the aqueous solution after ion-exchange, and consequently the distance of ThT-colored area reflects the sample K+ concentration. The ion exchange reaction was operated in a so-called "exhaustive sensing mode" and gave a distinct response in a narrow range of K+ concentration (16 mM) that cannot be achieved by the classical optode sensing mode. The absence of hydrogen ions from the equilibrium competition of the capillary sensor contributed to a complete pH-independence, unlike conventional optodes that contain a pH sensitive indicator. A very high selectivity for K+ over Na+ and Ca2+ has been confirmed in separate solutions and mixed solutions tests. K+ measurements in pooled serum samples at concentrations between 2 and 6 mM are successfully demonstrated on a temperature controlled support.
引用
收藏
页码:670 / 677
页数:15
相关论文
共 50 条
  • [1] Paper-Based Ion-Selective Potentiometric Sensors
    Novell, Marta
    Parrilla, Marc
    Crespo, Gaston A.
    Xavier Rius, F.
    Andrade, Francisco J.
    ANALYTICAL CHEMISTRY, 2012, 84 (11) : 4695 - 4702
  • [2] Equipment-Free Quantitative Measurement for Microfluidic Paper-Based Analytical Devices Fabricated Using the Principles of Movable-Type Printing
    Zhang, Yun
    Zhou, Caibin
    Nie, Jinfang
    Le, Shangwang
    Qin, Qun
    Liu, Fang
    Li, Yuping
    Li, Jianping
    ANALYTICAL CHEMISTRY, 2014, 86 (04) : 2005 - 2012
  • [3] Detection methods and applications of microfluidic paper-based analytical devices
    Fu, Lung-Ming
    Wang, Yao-Nan
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 107 : 196 - 211
  • [4] A Review on Microfluidic Paper-Based Analytical Devices for Glucose Detection
    Liu, Shuopeng
    Su, Wenqiong
    Ding, Xianting
    SENSORS, 2016, 16 (12) : 1 - 17
  • [5] Microfluidic Paper-Based Analytical Devices for Colorimetric Detection of Lactoferrin
    Kudo, Hiroko
    Maejima, Kento
    Hiruta, Yuki
    Citterio, Daniel
    SLAS TECHNOLOGY, 2020, 25 (01): : 47 - 57
  • [6] Paper substrate modification for rapid capillary flow in microfluidic paper-based analytical devices
    Xu, Y.
    Enomae, T.
    RSC ADVANCES, 2014, 4 (25): : 12867 - 12872
  • [7] Novel concept of washing for microfluidic paper-based analytical devices based on capillary force of paper substrates
    Mohammadi, Saeed
    Alamo Busa, Lori Shayne
    Maeki, Masatoshi
    Mohamadi, Reza M.
    Ishida, Akihiko
    Tani, Hirofumi
    Tokeshi, Manabu
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (27) : 7559 - 7563
  • [8] Novel concept of washing for microfluidic paper-based analytical devices based on capillary force of paper substrates
    Saeed Mohammadi
    Lori Shayne Alamo Busa
    Masatoshi Maeki
    Reza M. Mohamadi
    Akihiko Ishida
    Hirofumi Tani
    Manabu Tokeshi
    Analytical and Bioanalytical Chemistry, 2016, 408 : 7559 - 7563
  • [9] Electrochemical microfluidic paper-based analytical devices for tumor marker detection
    Yuan, Yingying
    Liu, Bo
    Wang, Tianlu
    Li, Na
    Zhang, Zhengyao
    Zhang, Hangyu
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 157
  • [10] Microfluidic paper-based analytical devices with instrument-free detection and miniaturized portable detectors
    Kaneta, Takashi
    Alahmad, Waleed
    Varanusupakul, Pakorn
    APPLIED SPECTROSCOPY REVIEWS, 2019, 54 (02) : 117 - 141