Characteristics and outcomes of diabetic patients with an implantable cardioverter defibrillator in a real world setting: results from the Israeli ICD registry

被引:7
|
作者
Steiner, Hillel [1 ,2 ,9 ]
Geist, Michael [1 ,2 ]
Goldenberg, Ilan [2 ,3 ]
Suleiman, Mahmoud [4 ]
Glikson, Michael [2 ,3 ]
Tenenbaum, Alexander [2 ,3 ,5 ]
Swissa, Moshe [6 ,7 ]
Fisman, Enrique Z. [2 ,3 ,5 ]
Golovchiner, Gregory [8 ]
Strasberg, Boris [8 ]
Barsheshet, Alon [8 ]
机构
[1] Edith Wolfson Med Ctr, Holon, Israel
[2] Tel Aviv Univ, Sackler Sch Med, Tel Aviv, Israel
[3] Chaim Sheba Med Ctr, Tel Hashomer, Israel
[4] Rambam Med Ctr, Haifa, Israel
[5] Cardiovasc Diabetol Res Fdn, Holon, Israel
[6] Kaplan Med Ctr, Rehovot, Israel
[7] Hebrew Univ Jerusalem, Jerusalem, Israel
[8] Rabin Med Ctr, Petah Tiqwa, Israel
[9] Edith Wolfson Med Ctr, Dept Cardiol, Holon, Israel
关键词
Implantable cardioverter defibrillator; Diabetes mellitus; Heart failure; Outcomes; CARDIAC-RESYNCHRONIZATION THERAPY; ATRIAL-FIBRILLATION; HEART-FAILURE; HIGH-RISK; MYOCARDIAL-INFARCTION; PRIMARY PREVENTION; APPROPRIATE SHOCK; GLUCOSE LEVEL; SUDDEN-DEATH; FOLLOW-UP;
D O I
10.1186/s12933-016-0478-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: There are limited data regarding the effect of diabetes mellitus (DM) on the risks of both appropriate and inappropriate implantable cardioverter defibrillator (ICD) therapy. The present study was designed to compare the outcome of appropriate and inappropriate ICD therapy in patients with or without DM. Methods and results: The risk of a first appropriate ICD therapy for ventricular tachyarrhythmias (including anti tachycardia pacing and shock) was compared between 764 DM and 1346 non-DM patients enrolled in the national Israeli ICD registry. We also compared the risks of inappropriate ICD therapy, and death or cardiac hospitalization between diabetic and non-diabetic patients. Diabetic patients were older, were more likely to have ischemic cardiomyopathy, lower ejection fraction, atrial fibrillation, and other co-morbidities. The 3-year cumulative incidence of appropriate ICD therapy was similar in the DM and non-DM groups (12 and 13%, respectively, p = 0.983). Multivariate analysis showed that DM did not affect the risk of appropriate ICD therapy (HR = 1.07, 95% CI 0.78-1.47, p = 0.694) or inappropriate therapy (HR = 0.72, 95% CI 0.42-1.23, p = 0.232). However, DM was associated with a 31% increased risk for death or cardiac hospitalization (p = 0.005). Results were similar in subgroup analyses including ICD and defibrillators with cardiac resynchronization therapy function recipients, primary or secondary prevention indication for an ICD. Conclusions: Despite a significant excess of cardiac hospitalizations and mortality in the diabetic population, there was no difference in the rate of ICD treatments, suggesting that the outcome difference is not related to arrhythmias.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Characteristics and outcomes of diabetic patients with an implantable cardioverter defibrillator in a real world setting: results from the Israeli ICD registry
    Hillel Steiner
    Michael Geist
    Ilan Goldenberg
    Mahmoud Suleiman
    Michael Glikson
    Alexander Tenenbaum
    Moshe Swissa
    Enrique Z. Fisman
    Gregory Golovchiner
    Boris Strasberg
    Alon Barsheshet
    Cardiovascular Diabetology, 15
  • [2] Clinical characteristics and outcomes of elderly patients treated with an implantable cardioverter-defibrillator or cardiac resynchronization therapy in a real-world setting: Data from the Israeli ICD Registry
    Suleiman, Mahmoud
    Goldenberg, Ilan
    Haim, Moti
    Schliamser, Jorge E.
    Boulos, Monther
    Ilan, Michael
    Swissa, Moshe
    Gavrielov-Yusim, Natalie
    Fuchs, Therese
    Amit, Guy
    Glikson, Michael
    HEART RHYTHM, 2014, 11 (03) : 435 - 441
  • [3] Assessing the outcomes of implantable cardioverter defibrillator treatment in a real world setting: results from hospital record data
    Ghislandi, Simone
    Torbica, Aleksandra
    Boriani, Giuseppe
    BMC HEALTH SERVICES RESEARCH, 2013, 13
  • [4] Assessing the outcomes of implantable cardioverter defibrillator treatment in a real world setting: results from hospital record data
    Simone Ghislandi
    Aleksandra Torbica
    Giuseppe Boriani
    BMC Health Services Research, 13
  • [5] Sex differences in implantable cardioverter-defibrillator implantation indications and outcomes: lessons from the Nationwide Israeli-ICD Registry
    Amit, Guy
    Suleiman, Mahmoud
    Konstantino, Yuval
    Luria, David
    Kazatsker, Mark
    Chetboun, Israel
    Haim, Moti
    Gavrielov-Yusim, Natalie
    Goldenberg, Ilan
    Glikson, Michael
    EUROPACE, 2014, 16 (08): : 1175 - 1180
  • [6] Role of defibrillation threshold testing during implantable cardioverter-defibrillator placement: Data from the Israeli ICD Registry
    Arnson, Yoav
    Suleiman, Mahmoud
    Glikson, Michael
    Sela, Ron
    Geist, Michael
    Amit, Guy
    Schliamser, Jorge E.
    Goldenberg, Ilan
    Ben-Zvi, Shlomit
    Orvin, Katia
    Rosenheck, Shimon
    Freedberg, Nahum Adam
    Strasberg, Boris
    Haim, Moti
    HEART RHYTHM, 2014, 11 (05) : 814 - 821
  • [7] Cardiac resynchronization and implantable cardioverter defibrillator therapy:: Preliminary results from the InSync Implantable Cardioverter Defibrillator Italian Registry
    Gasparini, M
    Lunati, M
    Bocchiardo, M
    Mantica, M
    Gronda, E
    Frigerio, M
    Caponi, D
    Carboni, A
    Boriani, G
    Zanotto, G
    Ravazzi, PA
    Curnis, A
    Puglisi, A
    Klersy, C
    Vicini, I
    Cavaglià, S
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (01): : 148 - 151
  • [8] Subcutaneous implantable cardioverter defibrillator in children and adolescents: results from the S-ICD “Monaldi care” registry
    Berardo Sarubbi
    Diego Colonna
    Anna Correra
    Emanuele Romeo
    Michele D’Alto
    Maria Teresa Palladino
    Salvatore Virno
    Antonio D’Onofrio
    Maria Giovanna Russo
    Journal of Interventional Cardiac Electrophysiology, 2022, 63 : 283 - 293
  • [9] Subcutaneous implantable cardioverter defibrillator in children and adolescents: results from the S-ICD "Monaldi care" registry
    Sarubbi, Berardo
    Colonna, Diego
    Correra, Anna
    Romeo, Emanuele
    D'Alto, Michele
    Palladino, Maria Teresa
    Virno, Salvatore
    D'Onofrio, Antonio
    Russo, Maria Giovanna
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 63 (02) : 283 - 293
  • [10] Real world battery longevity of the subcutaneous implantable cardioverter-defibrillator (S-ICD)
    Van der Stuijt, W.
    Williams, J. L.
    Brisben, A. J.
    Koshiol, A. T.
    Carter, N.
    Madias, C.
    Ip, J. E.
    Link, M. S.
    Saba, S. F.
    EUROPEAN HEART JOURNAL, 2023, 44