关键词
laboratory research; pressure ulcer; prevention; dressings; CRITICALLY-ILL PATIENTS; HEEL PRESSURE ULCERS; PREVENTION; FOAM; INJURY; MUSCLE; RISK;
D O I
10.25270/owm.10.4855
中图分类号
R61 [外科手术学];
学科分类号
摘要
The sacrum is the most susceptible anatomical site for developing pressure injuries, including deep tissue injuries, during supine lying. Prophylactic dressings generally are designed to reduce friction, alleviate internal tissue shear, manage the microclimate, and overall cushion the soft tissues subjected to sustained deformations under the sacrum. Using computational modeling, the authors developed a set of 8 magnetic resonance imaging-based, 3-dimensional finite element models of the buttocks of a healthy 28-year-old woman for comparing the biomechanical effects of different prophylactic sacral dressing designs when used during supine lying on a standard hospital foam mattress. Computer simulation data from model variants incorporating an isotropic (same stiffness in every direction) multilayer compliant dressing, an anisotropic (directionally dependent stiffness properties) multilayer compliant dressing, and a completely stiff dressing were compared to control (no dressing). Specific outcome measures that were compared across these simulation cases were strain energy density (SED) and maximal shear stresses in a volume of interest (VOI) of soft tissues surrounding the sacrum. The SED and shear stress measurements were obtained in pure compression loading of the buttocks (ie, simulating a horizontal supine bed rest) and in combined compression-and-shear loads applied to the buttocks (ie, 45 degrees Fowler position causing frictional and shear forces) on a standard foam mattress. Compared to the isotropic dressing design, the anisotropic dressing facilitated more soft tissue protection through an additional 11% reduction in exposure to SED at the VOI. In this model, use of the anisotropic compliant dressing resulted in the lowest exposures to internal tissue SED and shear stresses. Research to examine the clinical inference of this modeling technique and studies to compare the effects of prophylactic dressings on healthy volunteers and patients in different positions are warranted.
引用
收藏
页码:48 / 55
页数:8
相关论文
共 50 条
  • [1] Release of sodium pyruvate from sacral prophylactic dressings: A computational model
    Levy, Ayelet
    Kottner, Jan
    Gefen, Amit
    INTERNATIONAL WOUND JOURNAL, 2019, 16 (04) : 1000 - 1008
  • [2] Prophylactic sacral protective dressings' effect on preventing pressure injury: A meta-analysis
    Gong, Xinyan
    Xu, Ruimin
    INTERNATIONAL WOUND JOURNAL, 2022, 19 (06) : 1463 - 1470
  • [3] Effects of loading and prophylactic dressings on the sacral and heel skin: An exploratory cross-over trial
    Lichterfeld-Kottner, Andrea
    Vogt, Annika
    Tomova-Simitchieva, Tsenka
    Blume-Peytavi, Ulrike
    Kottner, Jan
    INTERNATIONAL WOUND JOURNAL, 2021, 18 (06) : 909 - 922
  • [4] A Computer Modeling Study to Assess the Durability of Prophylactic Dressings Subjected to Moisture in Biomechanical Pressure Injury Prevention
    Schwartz, Dafna
    Levy, Ayelet
    Gefen, Amit
    OSTOMY WOUND MANAGEMENT, 2018, 64 (07) : 18 - 26
  • [5] Effectiveness of prophylactic sacral protective dressings to prevent pressure injury: A systematic review and meta-analysis
    Fulbrook, Paul
    Mbuzi, Vainess
    Miles, Sandra
    INTERNATIONAL JOURNAL OF NURSING STUDIES, 2019, 100
  • [6] Biomechanical modeling of brace treatment of scoliosis: effects of gravitational loads
    Julien Clin
    Carl-Éric Aubin
    Stefan Parent
    Hubert Labelle
    Medical & Biological Engineering & Computing, 2011, 49 : 743 - 753
  • [7] Biomechanical modeling of brace treatment of scoliosis: effects of gravitational loads
    Clin, Julien
    Aubin, Carl-Eric
    Parent, Stefan
    Labelle, Hubert
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2011, 49 (07) : 743 - 753
  • [8] Biomechanical effects of different loads and constraints on finite element modeling of the humerus
    Islam, Sabrina
    Gide, Kunal
    Schemitsch, Emil H.
    Bougherara, Habiba
    Zdero, Radovan
    Bagheri, Z. Shaghayegh
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2023,
  • [9] Biomechanical Effects of a Cross Connector in Sacral Fractures - A Finite Element Analysis
    Gierig, Meike
    Liu, Fangrui
    Weiser, Lukas
    Lehmann, Wolfgang
    Wriggers, Peter
    Marino, Michele
    Saul, Dominik
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 09
  • [10] The contribution of a directional preference of stiffness to the efficacy of prophylactic sacral dressings in protecting healthy and diabetic tissues from pressure injury: computational modelling studies
    Levy, Ayelet
    Schwartz, Dafna
    Gefen, Amit
    INTERNATIONAL WOUND JOURNAL, 2017, 14 (06) : 1370 - 1377