Towards more accurate design and specification of aeration systems using on-site column testing

被引:10
|
作者
Rosso, Diego [1 ]
Jiang, Lu-Man [1 ]
Hayden, David M. [2 ]
Pitt, Paul [3 ]
Hocking, Charles S. [3 ]
Murthy, Sudhir [4 ]
Stenstrom, Michael K. [5 ]
机构
[1] Univ Calif Irvine, Dept Civil & Environm Engn, Irvine, CA 92697 USA
[2] Irvine Ranch Water Dist, Irvine, CA 92612 USA
[3] Hazen & Sawyer PC, New York, NY 10018 USA
[4] DC Water, Washington, DC 20032 USA
[5] Univ Calif Los Angeles, Dept Civil & Environm Engn, Los Angeles, CA 90095 USA
关键词
activated sludge; aeration; design; energy footprint; fouling; oxygen transfer efficiency; TRANSFER EFFICIENCY; DIFFUSERS;
D O I
10.2166/wst.2012.187
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Fine-pore diffuser systems are selected for their potential energy efficiency, and during design their propensity for fouling and for an increase in pressure drop with time must be considered. Both fouling and pressure-drop increase cause an increase in blower power requirements. This paper presents a new approach to improve this design procedure, without altering the technical structure of the classical approach. While the administrative and bidding milestones are being carried out (i.e., in the first 6 months of the project milestones), an independent aeration team can test candidate diffusers suitable for design in an aeration column in situ. An extended fouling test in the plant's aeration tanks allows the collection of site-specific aeration performance data. These improve the accuracy of the design process, and limit the reliance on safety factors.
引用
收藏
页码:627 / 634
页数:8
相关论文
共 50 条
  • [1] Methodology for In Situ Column Testing to Improve Accuracy during Design and Specification of Aeration Systems
    Rosso, Diego
    Jiang, Lu-Man
    Pitt, Paul
    Hocking, Charles S.
    Stenstrom, Michael K.
    Murthy, Sudhir
    Hayden, David M.
    Zhong, Joseph
    Coller, Daniel H.
    Kim, Andrew Y.
    Xu, Haomin
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2013, 139 (04): : 530 - 537
  • [2] Towards on-site testing of Phytophthora species
    Schwenkbier, Lydia
    Pollok, Sibyll
    Koenig, Stephan
    Urban, Matthias
    Werres, Sabine
    Cialla-May, Dana
    Weber, Karina
    Popp, Juergen
    ANALYTICAL METHODS, 2015, 7 (01) : 211 - 217
  • [3] Towards more accurate brake testing
    Slevin, EJ
    Smales, H
    BRAKING 2002: FROM THE DRIVER TO THE ROAD, 2002, : 15 - 24
  • [4] DESIGN OF ENZYME IMMUNOASSAYS FOR ON-SITE TESTING
    BLEILE, DM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1986, 192 : 71 - AGFD
  • [5] Towards More Accurate and Intelligent Recommendation Systems
    Kahara, Timo
    Haataja, Keijo
    Toivanen, Pekka
    2013 13TH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS DESIGN AND APPLICATIONS (ISDA), 2013, : 165 - 171
  • [6] On-site Ammonia Production Systems Towards the Practical Application
    Munenobu I.T.O.
    Yosetsu Gakkai Shi/Journal of the Japan Welding Society, 2022, 91 (06): : 64 - 67
  • [7] DESIGN OF ON-SITE TREATMENT SYSTEMS IN CALICHE SOILS
    LILJESTRAND, HM
    PARTEN, SM
    WATER SCIENCE AND TECHNOLOGY, 1993, 28 (10) : 83 - 87
  • [8] Design and Implementation of On-site Testing Module of College English General Testing System
    Dong, Shiting
    Qi, Jiahui
    Ye, Yan
    Wu, Min
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON MECHATRONICS ENGINEERING AND INFORMATION TECHNOLOGY (ICMEIT 2017), 2017, 70 : 534 - 538
  • [9] Development of a molecular method for testing the effectiveness of UV systems on-site
    Nizri, Limor
    Vaizel-Ohayon, Dalit
    Ben-Amram, Hila
    Sharaby, Yehonatan
    Halpern, Malka
    Mamane, Hadas
    WATER RESEARCH, 2017, 127 : 162 - 171
  • [10] On-site tertiary treatment using Ecomax systems
    Bowman, M
    DESALINATION, 1996, 106 (1-3) : 305 - 310