The angle stable Locking-Proximal-Humerus-Plate (LPHP®) for proximal humeral fractures using a small anterior-lateral-deltoid-splitting-approach -: Technique and first results

被引:0
|
作者
Lill, H [1 ]
Hepp, P [1 ]
Rose, T [1 ]
König, K [1 ]
Josten, C [1 ]
机构
[1] Univ Leipzig, Klin Unfall Wiederherstellungschirug, Leipzig, Germany
来源
ZENTRALBLATT FUR CHIRURGIE | 2004年 / 129卷 / 01期
关键词
proximal humeral fracture; multiple part fractures; anteriorlateral deltoid-splitting-approach; plate osteosynthesis; angle stable;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
The Locking-Proximal-Humerus-Plate (LPHP) was slided from proximally to distally through a small anterior-lateral-deltoid-splitting-approach following a closed reduction. Additional tension band wiring for the rotator cuff was fixed at the plate after screw insertion. The prospective study included 35 patients (age median: 63 years, range: 33-92; male: 13, female: 22) from 08/01-05/02. The follow-up period was set to 3 months postoperatively, whereas 29 patients were able to attend. The patientgroup with 2-part fractures (n = 8) showed an average Constant score of 77.6 points ( +/- 10.7, "good"), the patients with 3-part fractures (n = 16) an average score of 75.1 points ( +/- 14.4, "good") and the patients with 4-part fractures (n = 5) an average score of 64.8 points ( +/- 10.4, "moderate"). Specific, approach-related problems were not observed. Almost all fractures revealed bony union during the first 3 months and only one loss of reduction was found. A screw loosening in 2 cases and a break of the plate in 3 cases were seen as implant related problems, and furthermore in 5 cases the screws placed in the humeral head were too long. Only one early re-osteosynthesis with the same plate was necessary due to an initial non-correct reposition. As demonstrated by these good short-term results, this technique seems to be a suitable procedure for displaced humeral head fractures.
引用
收藏
页码:43 / 48
页数:6
相关论文
共 32 条
  • [1] Die winkelstabile Plattenosteosynthese bei Frakturen am proximalen Humerus mit der LPHP (Locking Proximal Humerus Plate)Internal Fixation of Proximal Humerus Fractures Using the Locking Proximal Humerus Plate
    Michael Plecko
    Aurel Kraus
    Operative Orthopädie und Traumatologie, 2005, 17 (1) : 25 - 50
  • [2] The results of ORIF of displaced unstable proximal humeral fractures using a locking plate
    Duralde, Xavier A.
    Leddy, Lee R.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (04) : 480 - 488
  • [3] Application of Intramedullary Calcar Support Plate and Lateral Locking Plate in Elderly Patients with Neer 3 and 4-Part Fractures of Proximal Humerus Through a Deltoid Splitting Approach
    Wang, Yijun
    Zhao, Liang
    Liu, Can
    Qin, Kang
    INDIAN JOURNAL OF ORTHOPAEDICS, 2024, 58 (04) : 362 - 370
  • [4] Application of Intramedullary Calcar Support Plate and Lateral Locking Plate in Elderly Patients with Neer 3 and 4-Part Fractures of Proximal Humerus Through a Deltoid Splitting Approach
    Yijun Wang
    Liang Zhao
    Can Liu
    Kang Qin
    Indian Journal of Orthopaedics, 2024, 58 : 362 - 370
  • [5] Proximal humeral fractures: The role of calcium sulphate augmentation and extended deltoid splitting approach in internal fixation using locking plates
    Somasundaram, K.
    Huber, C. P.
    Babu, V.
    Zadeh, H.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (04): : 481 - 487
  • [6] Open Reduction and Internal Fixation of Proximal Humeral Fractures with Use of the Locking Proximal Humerus Plate Results of a Prospective, Multicenter, Observational Study
    Suedkamp, N.
    Bayer, J.
    Hepp, P.
    Voigt, C.
    Oestern, H.
    Kaeaeb, M.
    Luo, C.
    Plecko, M.
    Wendt, K.
    Koestler, W.
    Konrad, G.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (06): : 1320 - 1328
  • [7] The Plate-Joystick Technique to Reduce Proximal Humeral Fractures and Nonunions With a Varus Deformity Through the Extended Deltoid-Splitting Approach
    Robinson, C. Michael
    Inman, Dominic
    Phillips, Sally-Anne
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (10) : 634 - 640
  • [8] Results after treatment of instable fractures of the proximal humerus using a fixed-angle plate
    Hessler, C.
    Schmucker, U.
    Matthes, G.
    Ekkernkamp, A.
    Guetschow, R.
    Eggers, C.
    UNFALLCHIRURG, 2006, 109 (10): : 867 - +
  • [9] Long term results of minimal invasive deltoid split versus standard del-toidopectoral approach for PHILOS (proximal humeral internal locking system) osteosynthesis in proximal humeral fractures
    Borer, J.
    Babians, A.
    Schwarz, J.
    Potthast, S.
    Jakob, M.
    Lenzlinger, P.
    Zingg, U.
    BRITISH JOURNAL OF SURGERY, 2017, 104 : 16 - 16
  • [10] Assessment of Screw Length of Proximal Humerus Internal Locking System (PHILOS) Plate for Proximal Humeral Fractures Using Three-Dimensional Computed Tomography Scan
    Qiang, Minfei
    Jia, Xiaoyang
    Chen, Yanxi
    Zhang, Kun
    Li, Haobo
    Jiang, Yuchen
    Zhang, Yijie
    MEDICAL SCIENCE MONITOR, 2018, 24 : 1158 - 1165