Neutral Carrier-Based Zinc-Selective Electrode

被引:0
|
作者
Kumar, Pawan [1 ]
Mittal, Susheel K. [1 ]
Kumar, S. K. Ashok [2 ]
机构
[1] Thapar Univ, Sch Chem & Biochem, Patiala 147004, Punjab, India
[2] VIT Univ, Sch Adv Sci, Vellore 632014, Tamil Nadu, India
关键词
Ion-Selective Electrode; Zinc(II) Ion; TPEN; Selectivity Coefficient; Indicator Electrode; MEMBRANE POTENTIOMETRIC SENSOR; COMPLEX-FORMATION CONSTANTS; NONIONIC SURFACTANTS; IONOPHORES;
D O I
10.1166/sl.2012.2581
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new PVC based liquid membrane containing N,N,N',N'-Tetrakis(2-pyridylmethyl) ethylenediamine (I) as an ionophore has been developed as zinc ion-selective electrode. The best performance was observed with an electrode composition (w/w); PVC (33%), 2-nitro phenyloctylether (60%), ionophore (I) (5%) and sodium tetrakis(4-chlorophenyl) borate as lipophilic salt (NaTpCIPB, 2%). The electrode shows a linear dynamic response in the concentration range 5.0 x 10(-6) M to 1.0 x 10(-1) M with a Nernstian slope of 30 mV/decade and a detection limit as 1 x 10(-6) M. It has a response time of 20 seconds and can be used for at least 4 months without any significant divergence in potentials. The proposed sensor shows good selectivity with respect to alkali, alkaline earth and transition metal ions. It can be used in the pH range 3.0-8.0 and electrode has been used as an indicator electrode in potentiometric titrations of zinc(II) ions with Na2S. The electrode also has been applied successfully for the determination of zinc ions in real life samples.
引用
收藏
页码:979 / 984
页数:6
相关论文
共 50 条
  • [1] NEUTRAL CARRIER-BASED MAGNESIUM-SELECTIVE ELECTRODE
    SALEH, MB
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 373 (1-2): : 89 - 95
  • [2] ZINC-SELECTIVE MEMBRANE-ELECTRODE USING TETRABUTYL THIURAM DISULFIDE NEUTRAL CARRIER
    KOJIMA, R
    KAMATA, S
    ANALYTICAL SCIENCES, 1994, 10 (03) : 409 - 412
  • [3] Zinc-selective electrode
    Gyrdasova, OI
    Volkov, VL
    JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 53 (06) : 535 - 538
  • [4] NEUTRAL CARRIER-BASED NA+-SELECTIVE ELECTRODE FOR APPLICATION IN BLOOD-SERUM
    MARUIZUMI, T
    WEGMANN, D
    SUTER, G
    AMMANN, D
    SIMON, W
    MIKROCHIMICA ACTA, 1986, 1 (5-6) : 331 - 336
  • [5] A zinc-selective electrode based on N,N′-bis(acetylacetone)ethylenediimine
    Gupta, VK
    Agarwal, S
    Jakob, A
    Lang, H
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (02) : 812 - 818
  • [6] Acyclic neutral carrier-based polymer membrane electrode for a stimulant, phentermine
    Katsu, T
    Ido, K
    Kataoka, K
    ANALYTICAL SCIENCES, 2001, 17 (06) : 745 - 749
  • [7] Acyclic Neutral Carrier-Based Polymer Membrane Electrode for a Stimulant, Phentermine
    Takashi Katsu
    Kazuyuki Ido
    Kenji Kataoka
    Analytical Sciences, 2001, 17 : 745 - 749
  • [8] NEUTRAL CARRIER-BASED ION-SELECTIVE ELECTRODE WITH SIMILAR SENSITIVITY TO DIFFERENT MONOVALENT CATIONS AS A DETECTOR IN ION CHROMATOGRAPHY
    KWON, KH
    PAENG, KJ
    LEE, DK
    LEE, IC
    HONG, US
    CHA, GS
    JOURNAL OF CHROMATOGRAPHY A, 1994, 688 (1-2) : 350 - 356
  • [9] NEW NEUTRAL CARRIER-BASED H+ SELECTIVE-MEMBRANE ELECTRODES
    COSOFRET, VV
    NAHIR, TM
    LINDNER, E
    BUCK, RP
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 327 (1-2): : 137 - 146
  • [10] Tweezer-type neutral carrier-based calcium-selective membrane electrode with drastically reduced anionic interference
    Lee, MH
    Yoo, CL
    Lee, JS
    Cho, IS
    Kim, BH
    Cha, GS
    Nam, H
    ANALYTICAL CHEMISTRY, 2002, 74 (11) : 2603 - 2607