Implantable Bladder Sensors: A Methodological Review

被引:41
|
作者
Dakurah, Mathias Naangmenkpeong [1 ]
Koo, Chiwan [1 ]
Choi, Wonseok [2 ]
Joung, Yeun-Ho [1 ]
机构
[1] Hanbat Natl Univ, Dept Elect & Control Engn, Daejeon 34158, South Korea
[2] Hanbat Natl Univ, Dept Elect Engn, Daejeon 34158, South Korea
关键词
Urinary Incontinence; Implantable Bladder Sensor; Hermetic; Biocompatible Materials; Telemetry; PRESSURE SENSORS; SYSTEM; VOLUME; TELEMETRY; SILICON;
D O I
10.5213/inj.2015.19.3.133
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The loss of urinary bladder control/sensation, also known as urinary incontinence (UI), is a common clinical problem in autistic children, diabetics, and the elderly. UI not only causes discomfort for patients but may also lead to kidney failure, infections, and even death. The increase of bladder urine volume/pressure above normal ranges without sensation of UI patients necessitates the need for bladder sensors. Currently, a catheter-based sensor is introduced directly through the urethra into the bladder to measure pressure variations. Unfortunately, this method is inaccurate because measurement is affected by disturbances in catheter lines as well as delays in response time owing to the inertia of urine inside the bladder. Moreover, this technique can cause infection during prolonged use; hence, it is only suitable for short-term measurement Development of discrete wireless implantable sensors to measure bladder volume/pressure would allow for long-term monitoring within the bladder, while maintaining the patient's quality of life. With the recent advances in microfabrication, the size of implantable bladder sensors has been significantly reduced. However, microfabricated sensors face hostility from the bladder environment and require surgical intervention for implantation inside the bladder. Here, we explore the various types of implantable bladder sensors and current efforts to solve issues like hermeticity, biocompatibility, drift, telemetry, power, and compatibility issues with popular imaging tools such as computed tomography and magnetic resonance imaging. We also discuss some possible improvements/emerging trends in the design of an implantable bladder sensor.
引用
收藏
页码:133 / 141
页数:9
相关论文
共 50 条
  • [1] A REVIEW OF IMPLANTABLE SENSORS
    KO, WH
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1983, 6 (02): : 482 - 487
  • [2] Volumetry of the urinary bladder with implantable ultrasound sensors
    Scheepe, JR
    Bross, S
    Braun, P
    Seif, C
    Becker, K
    Nguyen, XP
    Alken, P
    Jünemann, KP
    Schumacher, S
    UROLOGE A, 2000, 39 (03): : 235 - 239
  • [4] TOWARDS IMPLANTABLE GLUCOSE SENSORS - A REVIEW
    WILKINS, ES
    JOURNAL OF BIOMEDICAL ENGINEERING, 1989, 11 (05): : 354 - 361
  • [5] A REVIEW OF DEVELOPMENTS IN IMPLANTABLE SELECTIVE CHEMICAL SENSORS
    KAZACOS, M
    SKALSKY, M
    SKYLLAS-KAZACOS, M
    LIFE SUPPORT SYSTEMS, 1985, 3 (03): : 189 - 205
  • [6] Implantable and Ingestible Sensors for Wireless Physiological Monitoring: A Review
    Kiourti, Asimina
    Shubair, Raed M.
    2017 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2017, : 1677 - 1678
  • [7] A technical review and evaluation of implantable sensors for hearing devices
    Diego Calero
    Stephan Paul
    André Gesing
    Fabio Alves
    Júlio A. Cordioli
    BioMedical Engineering OnLine, 17
  • [8] A technical review and evaluation of implantable sensors for hearing devices
    Calero, Diego
    Paul, Stephan
    Gesing, Andre
    Alves, Fabio
    Cordioli, Julio A.
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [9] Ultralow-Power Photoplethysmography (PPG) Sensors: A Methodological Review
    Ebrahimi, Zobair
    Gosselin, Benoit
    IEEE SENSORS JOURNAL, 2023, 23 (15) : 16467 - 16480
  • [10] NO improves implantable sensors
    Zubritsky, E
    ANALYTICAL CHEMISTRY, 2000, 72 (07) : 260A - 261A