Impact of Dosimetric Parameters on Interplay Effects in 6 MV Flattening Filter-Free Photon Beams to Treat Lung Cancer

被引:1
|
作者
Poolnapol, Vanida [1 ]
Sanghangthum, Taweap [1 ]
Keawsamur, Mintra [2 ]
机构
[1] Chulalongkorn Univ, Fac Med, Dept Radiol, Med Phys Program, Bangkok, Thailand
[2] King Chulalongkorn Mem Hosp, Dept Radiol, Div Radiat Oncol, Thai Red Cross Soc, Bangkok, Thailand
关键词
Flattening filter free; interplay effects; lung cancer; BODY RADIATION-THERAPY; MOTION; SBRT; RADIOTHERAPY; MANAGEMENT;
D O I
10.4103/jmp.jmp_63_21
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Context: Interplay effects have become the significant problem in lung cancer radiotherapy. Since these effects yield dose variation within the target and surrounding tissues. Aim: The aim of this study is to investigate the effect of the dosimetric parameters of interplay effects in 6 MV flattening filter-free (FFF) photon beams for lung cancer. Settings and Design: This study performed planning, measurement, and data analysis sections for examining different breathing amplitudes and phases, doses, dose rates, field sizes, and fractionations. Subjects and Methods: Standard and clinical plans were created on the eclipse treatment planning system. The static and dynamic measurements were performed using a robotic platform and two-dimensional (2D) diode array. The gamma passing rates were defined as the percent of dose variation caused by the interplay effects. Statistical Analysis Used: Unpaired t-test. Results: The outcomes showed three trends between gamma passing rates (gamma) and dosimetric parameters. First, a decreasing trend was breathing amplitudes. The lowest gamma of maximum amplitudes (2 cm) in both one dimensional and 2D were <25%. Second, an increasing trend was field sizes. The lowest gamma of minimum field size (4 cm x 4 cm(2)) was <55%. Third, constant outcomes were breathing phases, doses, dose rates, and a number of fractions. The gamma values of these factors were 53.1%, 55.1%, 34.7%, and 36.7%, respectively. Conclusions: Lung tumor motion-induced interplay effects in 6 MV FFF photon beams are more pronounced for higher breathing amplitudes and smaller field sizes.
引用
收藏
页码:20 / 26
页数:7
相关论文
共 50 条
  • [1] Dosimetric Evaluation of Flattening Filter-free (FFF) Photon Beams for Lung SBRT
    Chen, Q.
    Cai, J.
    Wu, Q.
    Yin, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S609 - S609
  • [2] Dosimetric impact of flattening filter and flattening filter-free beams on IMRT planning of NSCLC
    Lee, S. W. Y.
    Or, K. M. K.
    Kwong, Y. P. J.
    Choy, Y. H. S.
    Kwong, C. Y. K.
    Keung, H. K.
    Wu, V. W. C.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S485 - S486
  • [3] Dosimetric properties of a flattening filter-free 6-MV photon beam: A Monte Carlo study
    Mesbahi A.
    Mehnati P.
    Keshtkar A.
    Farajollahi A.
    Radiation Medicine, 2007, 25 (7): : 315 - 324
  • [4] Surface dose variations in 6 and 10 MV flattened and flattening filter-free (FFF) photon beams
    Cashmore, Jason
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05): : 293 - 307
  • [5] Dosimetric comparison of 6 MV and 10 MV flattening filter-free beams using small diameter cone for trigeminal neuralgia radiosurgery
    Blanco, Oscar Abel Apaza
    Venencia, Carlos Daniel
    Moreno, Rogelio Manuel Diaz
    Munoz, Fabian
    Barolo, Franco
    Muriano, Oscar
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2024, 23
  • [6] Small-field Dosimetry of 6-and 10-MV Flattening Filter-free and Flattening Filter Photon Beams for Therapeutic Use
    Shukla, Jooli
    Dwivedi, Shekhar
    Kansal, Sandeep
    Dangwal, Vinod Kumar
    Tiwari, K. P.
    Singla, Amit Kumar
    Rani, Supriya
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2023, 61 (10) : 846 - 850
  • [7] Impact of flattening filter-free beams on remaining volume at risk in lung cancer treatment
    Alfishawy, Mahmoud Mohamed
    Kany, Amr Ismail
    Elshahat, Khaled Mohamed
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2024, 63 (03) : 455 - 464
  • [8] Investigation of neutron contamination of flattening filter and flattening filter-free 10-MV photon beams in Elekta InfinityTM accelerator
    Yani S.
    Budiansah I.
    Lestari F.P.
    Tursinah R.
    Rhani M.F.
    Haryanto F.
    Iranian Journal of Medical Physics, 2020, 17 (02) : 126 - 132
  • [9] Interplay Effect During Lung SBRT With VMAT Delivered by Flattening Filter-Free Beams
    Rao, M.
    Ye, J.
    Spiegel, J.
    Takamiya, R.
    Mehta, V. K.
    Wu, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S192 - S192
  • [10] Survey on utilization of flattening filter-free photon beams in Japan
    Kodama, Takumi
    Yasui, Keisuke
    Nishioka, Shie
    Miyaura, Kazunori
    Takakura, Toru
    Katayose, Tetsurou
    Nakamura, Mitsuhiro
    JOURNAL OF RADIATION RESEARCH, 2021, 62 (04) : 726 - 734