Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

被引:0
|
作者
Yavas, G. [1 ]
Yavas, C. [2 ]
Acar, H. [1 ]
机构
[1] Selcuk Univ, Fac Med, Dept Radiat Oncol, Konya, Turkey
[2] Konya Training & Res Hosp, Dept Radiat Oncol, Konya, Turkey
来源
IRANIAN JOURNAL OF RADIATION RESEARCH | 2012年 / 10卷 / 3-4期
关键词
Breast cancer; conformal radiotherapy; dose volume histograms; field-in-field technique; INTENSITY-MODULATED RADIOTHERAPY; CONTRALATERAL BREAST; BOOST; CARCINOMAS; THERAPY; TRIALS; IMRT;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were created for the entire breast. FIF plans and CRT plans were compared for doses in the planning target volume (PTV), the organ at risk (OAR) volume including ipsilateral lung, heart, left ascending coronary artery (LAD) and the contralateral breast, the homogeneity index (HI), and the monitor unit (MU) counts required for the treatment. Paired samples t-test was used for statistical analysis. Results: The FIF technique significantly reduced the maximum dose of the PTV as well as the mean doses of the heart, LAD, ipsilateral lung and the contralateral breast (p values were <0.001 for each). When the OAR volumes irradiated with 2, 5, 10, 20, 30 and 40 Gy were compared, the results were in favor of the FT technique. The volume receiving <20 Gy of the prescription dose for the ipsilateral lung was significantly decreased using FIF technique (p<0.001). FIF technique allowed us more homogenous dose distribution with lower MUs. Conclusion: The FIF technique provided better dose distribution in the PTV and significantly reduced the doses in the OAR. Considering the lower MUs required for treatment the FIF technique seems to be more advantageous than CRT during whole breast irradiation. Iran. J. Radiat. Res., 2012; 10(3-4): 131-138
引用
收藏
页码:131 / 138
页数:8
相关论文
共 50 条
  • [1] DOSIMETRIC COMPARISON OF FIELD IN FIELD INTENSITY MODULATED RADIOTHERAPY TECHNIQUE WITH CONFORMAL RADIOTHERAPY TECHNIQUES IN BREAST CANCER
    Ercan, T.
    Igdem, S.
    Alco, G.
    Zengin, F.
    Ozgules, R.
    Atilla, S.
    Dincer, M.
    Okkan, S.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S201 - S202
  • [2] Dosimetric comparison of field in field intensity-modulated radiotherapy technique with conformal radiotherapy techniques in breast cancer
    Ercan, Tuelay
    Igdem, Sefik
    Alco, Guel
    Zengin, Funda
    Atilla, Selin
    Dincer, Maktav
    Okkan, Sait
    JAPANESE JOURNAL OF RADIOLOGY, 2010, 28 (04) : 283 - 289
  • [3] Dosimetric comparison of field in field intensity-modulated radiotherapy technique with conformal radiotherapy techniques in breast cancer
    Tülay Ercan
    Şefik İğdem
    Gül Alço
    Funda Zengin
    Selin Atilla
    Maktav Dinçer
    Sait Okkan
    Japanese Journal of Radiology, 2010, 28 : 283 - 289
  • [4] Dosimetric evaluation of whole breast radiotherapy using field-in-field technique in early-stage breast cancer
    Sasaoka, Masahiro
    Futami, Tomoyuki
    INTERNATIONAL JOURNAL OF CLINICAL ONCOLOGY, 2011, 16 (03) : 250 - 256
  • [5] Dosimetric evaluation of whole breast radiotherapy using field-in-field technique in early-stage breast cancer
    Masahiro Sasaoka
    Tomoyuki Futami
    International Journal of Clinical Oncology, 2011, 16 : 250 - 256
  • [6] Dosimetric comparison of conventional and field-infield techniques in early-stage breast cancer radiotherapy
    Hosseini, S. M.
    Momennezhad, M.
    Naseri, Sh
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (03): : 487 - 494
  • [7] Dosimetric Comparison of Whole Breast Radiotherapy Using Field-in-Field and Volumetric Modulated Arc Therapy Techniques in Left-Sided Breast Cancer Patients
    Waheed, Asmara
    Butt, Sumera
    Ishtiaq, Ali
    Mansha, Muhammad Atif
    Mehreen, Sana
    Raza, Mohsin
    Yousaf, Muhammad
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (06)
  • [8] Dosimetric Comparison of Irregular Surface Compensator and Field-in-Field for Whole Breast Radiotherapy
    Kuwahata, Nao
    Fujita, Hideki
    Yamanishi, Hideaki
    Okazaki, Eiichiro
    Fukuda, Haruyuki
    JOURNAL OF MEDICAL PHYSICS, 2018, 43 (02) : 79 - 84
  • [9] Determination and comparison of dosimetric parameters of three-dimensional conformal radiotherapy, field in field, and intensity-modulated radiotherapy techniques in radiotherapy of breast conserving patients
    Takabi, Fatemeh Shirani
    Broomand, Mohammad Ali
    Nickfarjam, Abolfazl
    Asadi, Amin
    Namiranian, Nasim
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 (03) : 624 - 632
  • [10] Dosimetric comparison of 3-dimensional conformal and field-in-field radiotherapy techniques for the adjuvant treatment of early stage endometrial cancer
    Yavas, Guler
    Yavas, Cagdas
    Acar, Hilal
    Buyukyoruk, Ahmet
    Cobanoglu, Gokcen
    Kerimoglu, Ozlem Secilmis
    Yavas, Ozlem
    Celik, Cetin
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (06): : 577 - 582