Research on Bake-out with Dilution Ventilation for Indoor Air Pollution

被引:0
|
作者
Lu, Yang [1 ]
Shu, Haiwen [1 ]
Liu, Jing
Li, Linlin
机构
[1] Dalian Univ Technol, Sch Civil Engn, Fac Infrastruct Engn, Dalian 116000, Peoples R China
来源
ADVANCES IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-6 | 2012年 / 518-523卷
关键词
Indoor air quality; Bake-out; Dilution ventilation; Formaldehyde; Volatile organic compounds (VOCs); SICK BUILDING SYNDROME; SYMPTOMS;
D O I
10.4028/www.scientific.net/AMR.518-523.2749
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Bake-out exhaust method was used to significantly accelerate the release of VOCs from building materials. This paper studies the bake-out technology with dilution ventilation for indoor air pollution by experimental works. The baking effectiveness of formaldehyde, benzene, toluene and xylene ranged from 3 to 7.6, 7.6 to 25, 5.1 to 17 and 6 to 22 for the six cases, respectively. Baking effectiveness would become higher at longer baking time and higher baking temperature for formaldehyde and VOCs released from decorative materials. However, considering the possible deformation of building materials, 40 degrees C and 10 hr would be the best choice for a suitable bake-out.
引用
收藏
页码:2749 / 2752
页数:4
相关论文
共 50 条
  • [1] Research on bake-out technology with dilution ventilation for indoor air pollution
    Yang, Lu
    Jing, Liu
    Lu Bing-nan
    Jiang An-xi
    Zhang Jing-ru
    Bing, Xie
    Jing, Li
    Lei, Zhang
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 424 - 429
  • [2] Numerical value research on bake-out technology with dilution ventilation for building materials
    Lu, Yang
    Liu, Jing
    Lu, Bing-nan
    Jiang, An-xi
    Zhang, Jing-ru
    Xie, Bing
    Li, Jing
    Zhang, Lei
    BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 907 - 911
  • [3] Experimental and simulation study on bake-out with dilution ventilation technology for building materials
    Lv, Yang
    Liu, Jing
    Wei, Shanshan
    Wang, Haifeng
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2016, 66 (11) : 1098 - 1108
  • [4] Variation of Indoor Air Quality in a New Apartment Building by Bake-Out
    Kim, S. Y.
    Kim, K. Y.
    Han, Y. S.
    Koo, J. W.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH, 2010, 4 (02) : 263 - 270
  • [5] Bio-enhancement for treatment of indoor air polluted by bake-out exhaust of fitments
    Lu, Yang
    Lu, Bing-Nan
    Liu, Jing
    Bao, Lin-Lin
    Jiang, An-Xi
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2008, 40 (08): : 1261 - 1264
  • [6] BAKE-OUT FOR UHV CHAMBERS IN AIR AT ATMOSPHERIC PRESSURE
    SAMUEL, RL
    VACUUM, 1970, 20 (07) : 295 - &
  • [7] Analyzing the Bake-Out Effect in Winter for the Enhancement of Indoor Air Quality at New Apartments in UAE
    Mahmoud, Naglaa Sami Abdelaziz
    Jung, Chuloh
    BUILDINGS, 2023, 13 (04)
  • [8] Use of Biotechnology Coupled with Bake-Out Exhaust to Remove Indoor VOCs
    Lu, Yang
    Liu, Jing
    Yoshino, Hiroshi
    Lu, Bingnan
    Jiang, Anxi
    Li, Fen
    INDOOR AND BUILT ENVIRONMENT, 2012, 21 (06) : 741 - 748
  • [9] Bake-Out Strategy Considering Energy Consumption for Improvement of Indoor Air Quality in Floor Heating Environments
    Park, Seonghyun
    Seo, Janghoo
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (12)
  • [10] Air bake-out to reduce hydrogen outgassing from stainless steel
    Bernardini, M
    Braccini, S
    De Salvo, R
    Di Virgilio, A
    Gaddi, A
    Gennai, A
    Genuini, G
    Giazotto, A
    Losurdo, G
    Pan, HB
    Pasqualetti, A
    Passuello, D
    Popolizio, P
    Raffaelli, F
    Torelli, G
    Zhang, Z
    Bradaschia, C
    Del Fabbro, R
    Ferrante, I
    Fidecaro, F
    La Penna, P
    Mancini, S
    Poggiani, R
    Narducci, P
    Solina, A
    Valentini, R
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1998, 16 (01): : 188 - 193