A label-free aptasensor for the sensitive and specific detection of cocaine using supramolecular aptamer fragments/target complex by electrochemical impedance spectroscopy

被引:38
|
作者
Zhang, De-Wen [1 ]
Zhang, Fang-Ting [1 ]
Cui, Yi-Ran [1 ]
Deng, Qin-Pei [1 ]
Krause, Steffi [2 ]
Zhou, Ying-Lin [1 ]
Zhang, Xin-Xiang [1 ]
机构
[1] Peking Univ, Coll Chem, Key Lab Biochem & Mol Engn, BNLMS, Beijing 100871, Peoples R China
[2] Univ London, Sch Engn & Mat Sci, London E1 4NS, England
基金
中国国家自然科学基金;
关键词
Aptamer fragment; Cocaine; Supramolecular complex; Label-free; Electrochemical impedance spectroscopy; SENSING PLATFORM; SMALL MOLECULES; IMPEDIMETRIC APTASENSOR; PROTEIN INTERACTIONS; STRAND DISPLACEMENT; GOLD NANOPARTICLES; SENSOR; BIOSENSOR; ADENOSINE; PROBE;
D O I
10.1016/j.talanta.2012.01.049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and label-free aptasensor for sensitive and specific detection of cocaine was developed by measuring the change in electrochemical impedance spectra (EIS), based on the formation of a supramolecular aptamer fragments/substrate complex. An anticocaine aptamer was divided into two fragments, Cx and Cy. Three different sensing interfaces, called Au/Cx5S/MCE, Au/Cy3S/MCE and Au/Cy5S/MCE, were fabricated by immobilizing Cx or Cy on a gold electrode through modifying their 5' or 3' end with a thiolated group followed by the treatment with mercaptoethanol (MCE). The formation of the corresponding supramolecular aptamer fragments/cocaine complex was investigated via monitoring electrochemical impedance spectra in the presence of [Fe(CN)(6)](3-/4-). The interfacial electron transfer resistance (R-et) was found to depend strongly on the cocaine concentration. Since the supramolecular aptamer fragments/cocaine complex was formed on the electrode surface, the sensing interface strongly affected the sensitivity of the aptasensor. Au/Cx5S/MCE was shown to have good sensitivity within a cocaine detection range of 0.1-20 mu M. Moreover, MCE was shown to improve the sensitivity of the aptasensor greatly. Even without the help of amplification or labeling, cocaine concentrations as low as 100 nM could be easily detected by the impedimetric aptasensor developed. The specificity and regeneration of the cocaine aptasensor were also investigated and satisfactory results were obtained. The developed aptasensor was successfully applied to detect the cocaine in biological fluids. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:65 / 71
页数:7
相关论文
共 50 条
  • [1] Label-Free Aptasensor for Lysozyme Detection Using Electrochemical Impedance Spectroscopy
    Ortiz-Aguayo, Dionisia
    del Valle, Manel
    SENSORS, 2018, 18 (02)
  • [2] Label-free Electrochemical Cocaine Aptasensor Based on a Target-inducing Aptamer Switching Conformation
    Mei Hua
    Manlan Tao
    Ping Wang
    Yinfeng Zhang
    Zaisheng Wu
    Yanbing Chang
    Yunhui Yang
    Analytical Sciences, 2010, 26 : 1265 - 1270
  • [3] Label-free Electrochemical Cocaine Aptasensor Based on a Target-inducing Aptamer Switching Conformation
    Hua, Mei
    Tao, Manlan
    Wang, Ping
    Zhang, Yinfeng
    Wu, Zaisheng
    Chang, Yanbing
    Yang, Yunhui
    ANALYTICAL SCIENCES, 2010, 26 (12) : 1265 - 1270
  • [4] A Label-Free Electrochemical Aptasensor Based on a Truncated Aptamer for the Detection of Progesterone
    Yang, Jie
    Hou, Yucui
    Ren, Yi
    Tang, Chunhua
    Li, HuanHuan
    Huang, Jing
    Jiang, Hanbing
    Cai, Tongji
    Zhao, Jia
    Yu, Peng
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2022, 18 (11) : 2498 - 2507
  • [5] Aptamer-based biosensor for label-free detection of ethanolamine by electrochemical impedance spectroscopy
    Liang, Gang
    Man, Yan
    Jin, Xinxin
    Pan, Ligang
    Liu, Xinhui
    ANALYTICA CHIMICA ACTA, 2016, 936 : 222 - 228
  • [6] A label-free electrochemical aptasensor for sensitive myoglobin detection in meat
    Li, Caihong
    Li, Jian
    Yang, Xiaodi
    Gao, Ling
    Jing, Lijun
    Ma, Xiaoling
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 242 : 1239 - 1245
  • [7] A label-free electrochemical aptasensor for sensitive edifenphos detection in rice
    Arvand, Majid
    Gholami, Javad
    ANALYTICAL METHODS, 2020, 12 (09) : 1237 - 1243
  • [8] Label-free and sensitive faradic impedance aptasensor for the determination of lysozyme based on target-induced aptamer displacement
    Peng, Yage
    Zhang, Dongdong
    Li, Yan
    Qi, Honglan
    Gao, Qiang
    Zhang, Chengxiao
    BIOSENSORS & BIOELECTRONICS, 2009, 25 (01): : 94 - 99
  • [9] Selection of DNA aptamer for label-free electrochemical aptasensor for the detection of rubella virus
    Alharbi, Maha
    Rhouati, Amina
    Zourob, Mohammed
    TALANTA, 2024, 278
  • [10] Reusable, label-free electrochemical aptasensor for sensitive detection of small molecules
    Li, Bingling
    Du, Yan
    Wei, Hui
    Dong, Shaojun
    CHEMICAL COMMUNICATIONS, 2007, (36) : 3780 - 3782