Experimental Study of the Thermal Performance of a New Type of Building Reflective Coating in Hot Summer and Cold Winter Zone of China

被引:11
|
作者
Guo Xing-guo [1 ]
Wang Jia [1 ]
Wu Yue [1 ]
Ao Yu-qiang [1 ]
Liu Xiang-wei [1 ]
机构
[1] Nanchang Univ, Sch Civil Engn & Architecture, Nanchang, Jiangxi, Peoples R China
关键词
Experimental study; Thermal Performance; Building reflective coating;
D O I
10.1016/j.proeng.2017.10.416
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, a test house with two rooms was built on the roof of a building in Nanchang University. The wall structure is 20mm cement mortar + 240mm red brick wall + 20mm cement mortar. One of the rooms is painted with a reflective coating on the south wall and the other is a common one without painting reflective coating. The outdoor temperature and the indoor temperature of the experimental rooms are measured in summer and compared comparison is made. The thermal performance of the new reflective coating is evaluated in hot summer and cold winter zone of China. The results show that the indoor temperature of the room painted the reflective coating is lower than the temperature of the room without painting the reflective coating. The maximum difference is 4.32 degrees C It indicates that the material has good thermal performance. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:603 / 608
页数:6
相关论文
共 50 条
  • [1] Study on Thermal Behavior of an Experimental Low-energy Building in the Hot Summer and Cold Winter Zone of China
    Shi, Feng
    Yu, Zhuang
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2016, 15 (03) : 503 - 510
  • [2] Thermal performance of building wall materials in villages and towns in hot summer and cold winter zone in China
    Diao, RongDan
    Sun, Linzhu
    Yang, Fang
    APPLIED THERMAL ENGINEERING, 2018, 128 : 517 - 530
  • [3] Systematic evaluation of the thermal performance of building envelopes in hot summer and cold winter zone
    College of Civil Engineering, Hunan Univ., Changsha 410082, China
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2008, 35 (10): : 16 - 20
  • [4] Study on Building Energy Effciency of Reflective Coatings in Hot Summer and Warmer Winter Zone of China
    Liang, Qing
    Han, Xinxin
    Liu, Jing
    Xu, Gang
    RENEWABLE AND SUSTAINABLE ENERGY, PTS 1-7, 2012, 347-353 : 3139 - +
  • [5] An experimental study of the summer and winter thermal performance of an opaque ventilated facade in cold zone of China
    Lin, Zhenghao
    Song, Yehao
    Chu, Yingnan
    BUILDING AND ENVIRONMENT, 2022, 218
  • [6] THERMAL ENVIRONMENT COUPLED SIMULATION AND ANALYSIS OF A TEACHING BUILDING IN SUMMER IN HOT SUMMER AND COLD WINTER ZONE IN CHINA
    Jiang, X. B.
    Yang, C. Z.
    Liu, Z. H.
    Meng, N.
    Yang, J. J.
    Zhang, Q. L.
    Hu, W. L.
    7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 147 - 152
  • [7] Evaluation on energy and thermal performance for residential envelopes in hot summer and cold winter zone of China
    Yu, Jinghua
    Yang, Changzhi
    Tian, Liwei
    Liao, Dan
    APPLIED ENERGY, 2009, 86 (10) : 1970 - 1985
  • [8] Experimental exploration on airtightness performance of residential buildings in the hot summer and cold winter zone in China
    Zheng, Hanjie
    Long, Enshen
    Cheng, Zhu
    Yang, Zhao
    Jia, Yonghong
    BUILDING AND ENVIRONMENT, 2022, 214
  • [9] Study on energy saving effect of heat-reflective insulation coating on envelopes in the hot summer and cold winter zone
    Guo, W.
    Qiao, X.
    Huang, Y.
    Fang, M.
    Han, X.
    ENERGY AND BUILDINGS, 2012, 50 : 196 - 203
  • [10] Study on outdoor thermal comfort of factory areas during winter in hot summer and cold winter zone of China
    He, Xincheng
    Gao, Weijun
    Wang, Rui
    Yan, Diyang
    BUILDING AND ENVIRONMENT, 2023, 228