Analysis on air valve placement in long-distance water conveyance pipeline system

被引:0
|
作者
Huang, Shifeng [1 ]
FengWang [2 ]
HuiXu [1 ]
XiaoxianWei [1 ]
机构
[1] Hohai Univ Coll Water Resources & Hydropower, Nanjing, Jiangsu, Peoples R China
[2] Hohai Univ, Mech & Mat Coll, Nanjing, Jiangsu, Peoples R China
关键词
Pressure pipeline; Water hammer; Hydraulic transient process; Air valve placement; Potential dangerous location;
D O I
10.4028/www.scientific.net/AMR.610-613.2513
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Water hammer is one of the key factors that can cause accidents by the burst of pressure pipeline. Important features and related reasons of accidents caused by water hammer in long-distance water conveyance pipeline system were introduced, and protection measures were presented. An long-distant raw water conveyance pipeline project was taken as an example to study on the influence of protective effect by different placement schemes of air valves based on hydraulic transient simulation and analysis. Results shows that largest number of air valves does not reach the best and unreasonable placement of air valves might be the cause of an accident. It is critical to select the proper location of air valves, it is necessary to pay more attention on local hump in the front of pipeline near the pump and put exhaust valves instead of inlet valves at the back of pipeline (except some higher hump location).
引用
收藏
页码:2513 / +
页数:2
相关论文
共 50 条
  • [1] Long-distance conveyance using a pneumatic system
    Goecke, Volker
    ZKG INTERNATIONAL, 2013, 66 (12): : 56 - 65
  • [2] Study on Joint Protection of Air Tank and Air Valve in Long-Distance Water Supply System
    Chen, Xuyun
    Zhang, Jian
    Yu, Xiaodong
    Chen, Sheng
    Shi, Lin
    JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME, 2022, 144 (06):
  • [3] Long-distance Slurry Pipeline Valve Monitoring System Design and Application
    Yuan, Xuyi
    Wu, Jiande
    Fan, Yugang
    Wang, Xiaodong
    MECHATRONICS AND APPLIED MECHANICS, PTS 1 AND 2, 2012, 157-158 : 1427 - 1430
  • [4] Full 3D seismic analysis of a long-distance water conveyance tunnel
    Chen, Zhiyi
    Yu, Haitao
    Yuan, Yong
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2014, 10 (01) : 128 - 140
  • [5] RopeCon - A new way of long-distance conveyance
    Pillichshammer, C.
    Trieb, H.
    Flebbe, H.
    2002, Trans Tech Publications (22):
  • [6] Design of Long-distance Pipeline Remote Monitoring System
    Wu, Jin
    DIGITAL MANUFACTURING & AUTOMATION III, PTS 1 AND 2, 2012, 190-191 : 1121 - 1124
  • [7] Design and development of the long-distance pipeline monitoring system
    Li, Hui
    JOURNAL OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING, 2015, 15 (01) : 117 - 126
  • [8] Study on reducing height of surge tank in long-distance and multi-branch water conveyance system
    Shi L.
    Zhang J.
    Yu X.
    Xu H.
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2023, 51 (08): : 67 - 73
  • [9] Prevention and control of algae residue deposition in long-distance water conveyance project
    Long, Yan
    Yang, Tongxin
    Gao, Wei
    Liu, Yuxin
    Xu, Cheng
    Yang, Yilin
    ENVIRONMENTAL POLLUTION, 2024, 344
  • [10] Optimal valve closure for long-distance water transmission
    Yu, Jing-Yang
    Wu, Zheng-Yi
    Yuan, Yi-Xing
    Zhao, Ming
    Wu, Chen-Guang
    Sustainable Environment Research, 2010, 20 (05) : 287 - 291