Implant Abutment Screw Reverse Torque Values Before and After Plasma Cleaning

被引:18
|
作者
Micarelli, Costanza
Canullo, Luigi
Baldissara, Paolo [1 ]
Clementini, Marco [2 ]
机构
[1] Alma Mater Studiorum Univ Bologna, Sect Prosthodont, Dept Oral Sci, Bologna, Italy
[2] Univ Roma Tor Vergata, Dept Dent, Rome, Italy
关键词
D O I
10.11607/ijp.3396
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This in vitro study analyzed the reverse torque (RevT) of abutment screws following different cleaning treatments. A convenience sample of 50 customized titanium abutment screw complexes was divided into five groups: cleaning by steam (control group), cleaning by Argon plasma (test groups 1 and 2 [with chlorhexidine gel]), and replacement of old screws with new ones (test groups 3 and 4 [with chlorhexidine gel]). Abutments were screwed onto implants and tested for RevT. The RevT of the test groups was significantly higher than that of the control group. No statistically. significant difference between test groups was noted except between groups 2 and 3.
引用
收藏
页码:331 / 333
页数:3
相关论文
共 50 条
  • [1] Effect of Screw Channel Angulation on Reverse Torque Values of Dental Implant Abutment Screws
    Hu, Eric
    Petrich, Anton
    Imamura, Glen
    Hamlin, Christopher
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (09): : 969 - 972
  • [2] Effect of fluid contamination on the reverse torque values of abutment screws at implant-abutment connections
    Koosha, Sara
    Toraji, Sedigheh
    Mostafavi, Azam S.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (04): : 618 - 621
  • [3] Reverse Torque Value of Angulated Screw Channel Abutment before and after Cyclic Loading: An In Vitro Study
    Chen, Yu-Hsuan
    Wu, Yu-Ling
    Chen, Hung-Shyong
    Lin, Ching-Ping
    Wu, Aaron Yu-Jen
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (03)
  • [4] Evaluation of implant abutment screw tightening protocols on reverse tightening values: An in vitro study
    Alnasser, Abdullah H.
    Wadhwani, Chandur P. K.
    Schoenbaum, Todd R.
    Kattadiyil, Mathew T.
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (03): : 486 - 490
  • [5] Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit
    Velez, Jorge
    Pelaez, Jesus
    Lopez-Suarez, Carlos
    Agustin-Panadero, Ruben
    Tobar, Celia
    Suarez, Maria J.
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (08) : 1 - 13
  • [6] In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening
    Kose, Onur Dincer
    Karatasli, Burcin
    Demircan, Sabit
    Kose, Taha Emre
    Cene, Erhan
    Aya, Serhan Aydjn
    Erdem, Mehmet Ali
    Cankaya, Abdulkadir Burak
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [7] Effect of implant abutment screw materials and tightening protocols on reverse tightening values: An in vitro study
    Alnasser, Abdullah H.
    Wadhwani, Chandur P. K.
    Alsarraf, Esra Y.
    Kattadiyil, Mathew T.
    Lozada, Jaime
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (06): : 1310e1 - 1310e8
  • [8] An In Vitro Study of Fluid Contaminations Influences on Reverse Torque Values of Implant-Abutment Connections
    Yang, Shuying
    Qin, Yuan
    Guo, Xueyan
    Li, Yaqi
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [9] Implant-abutment screw removal torque values between customized titanium abutment, straight titanium abutment, and hybrid zirconia abutment after a million cyclic loading: an in vitro comparative study
    Disayut Klongbunjit
    Weerapan Aunmeungtong
    Pathawee Khongkhunthian
    International Journal of Implant Dentistry, 7
  • [10] Implant-abutment screw removal torque values between customized titanium abutment, straight titanium abutment, and hybrid zirconia abutment after a million cyclic loading: an in vitro comparative study
    Klongbunjit, Disayut
    Aunmeungtong, Weerapan
    Khongkhunthian, Pathawee
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)