Locked Versus Nonlocked Plate Fixation for First Metatarsophalangeal Arthrodesis: A Biomechanical Investigation

被引:27
|
作者
Hunt, Kenneth J. [1 ]
Barr, Cameron R. [1 ]
Lindsey, Derek P. [2 ]
Chou, Loretta B. [1 ]
机构
[1] Stanford Univ, Dept Orthopaed, Redwood City, CA 94063 USA
[2] VA Palo Alto Hlth Care Syst, Ctr Tissue Regenerat Repair & Restorat, Palo Alto, CA USA
关键词
First Metatarsophalangeal Arthrodesis; Hallux Rigidus; Hallux Valgus; Locked Plate; DOME-SHAPED REAMERS; JOINT ARTHRODESIS; DORSAL PLATE; FRACTURES; STIFFNESS; FAILURE; FEMUR; GAIT; LCP;
D O I
10.3113/FAI.2012.0984
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: First metatarsophalangeal (MTP) arthrodesis using dorsal plate fixation is a common procedure for painful conditions of the great toe. Locked plates have become increasingly common for arthrodesis procedures in the foot, including the hallux MTP joint. The biomechanical advantages and disadvantages of these plates are currently unknown. The purpose of this study was to compare locked and nonlocked plates used for first MTP fusion for strength and stiffness. Materials and Methods: The first ray of nine matched pairs of fresh-frozen cadaveric feet underwent dissection, preparation with cup-and-cone reamers, and fixation of the MTP joint with a compression screw and either a nonlocked or locked stainless steel dorsal plate. Each specimen was loaded in a cantilever fashion to 90 N at a rate of 3 Hz for a total of 250,000 cycles. The amount of plantar MTP gap was recorded using a calibrated extensometer. Load-to-failure testing was performed for all specimens that endured the entire cyclical loading. Stiffness was calculated from the final load-to-failure test. Results: The locked plate group demonstrated significantly less plantar gapping during fatigue endurance testing from cycle 10,000 through 250,000 (p < .05). Mean stiffness was significantly greater in the locked plate group compared with the nonlocked plate group (p = .02). There was no significant difference in load to failure between the two groups (p = .27). Conclusion: Compared with nonlocked plates, locked hallux MTP arthrodesis plates exhibited significantly less plantar gapping after 10,000 cycles of fatigue endurance testing and significantly greater stiffness in load-to-failure testing. Clinical Relevance: As the use of locked plate technology is becoming increasingly common for applications in the foot, a thorough understanding of the biomechanical characteristics of these implants may help optimize their indications and clinical use.
引用
收藏
页码:984 / 990
页数:7
相关论文
共 50 条
  • [1] Locked Versus Nonlocked Plate Fixation For Hallux MTP Arthrodesis
    Hunt, Kenneth J.
    Ellington, J. Kent
    Anderson, Robert B.
    Cohen, Bruce E.
    Davis, W. Hodges
    Jones, Carroll P.
    FOOT & ANKLE INTERNATIONAL, 2011, 32 (07) : 704 - 709
  • [2] Arthrodesis of the First Metatarsophalangeal Joint: A Retrospective Analysis of Plate versus Screw Fixation
    Dening, Jan
    van Erve, Ruud H. G. P.
    JOURNAL OF FOOT & ANKLE SURGERY, 2012, 51 (02): : 172 - 175
  • [3] Analysis of the Costs and Complications of First Metatarsophalangeal Joint Arthrodesis Comparing Locked and Non-locked Plate Fixation Constructs
    Haimes, Mark A.
    Roberts, Michael S.
    Bougioukas, Lauren
    Michelson, James D.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2023, 31 (21) : E1012 - E1020
  • [4] Biomechanical comparison of two fixation methods for first metatarsophalangeal joint arthrodesis
    Molloy, S
    Burkhart, BG
    Jasper, LE
    Solan, MC
    Campbell, JT
    Belkoff, SM
    FOOT & ANKLE INTERNATIONAL, 2003, 24 (02) : 169 - 171
  • [5] Arthrodesis of the first metatarsophalangeal joint-A biomechanical comparison of four fixation techniques
    Harris, Ella
    Moroney, Paul
    Tourne, Yves
    FOOT AND ANKLE SURGERY, 2017, 23 (04) : 268 - 274
  • [6] Endomedullary Screw Fixation for First Metatarsophalangeal Arthrodesis
    Migues, Atilio
    Calvi, Juan
    Sotelano, Pablo
    Carrasco, Marina
    Slullitel, Gaston
    Conti, Leonardo
    FOOT & ANKLE INTERNATIONAL, 2013, 34 (08) : 1152 - 1157
  • [7] Arthrodesis of the First Metatarsophalangeal Joint by Locking Plate
    Kunovsky, R.
    Pink, T.
    Jarosik, J.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2017, 84 (06) : 453 - 461
  • [8] Weight-bearing recommendations after first metatarsophalangeal joint arthrodesis fixation: a biomechanical comparison
    Campbell, Bradley
    Schimoler, Patrick
    Belagaje, Sudhir
    Miller, M. C.
    Conti, S. F.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
  • [9] Weight-bearing recommendations after first metatarsophalangeal joint arthrodesis fixation: a biomechanical comparison
    Bradley Campbell
    Patrick Schimoler
    Sudhir Belagaje
    M. C. Miller
    S. F. Conti
    Journal of Orthopaedic Surgery and Research, 12
  • [10] Lapidus arthrodesis in combination with arthrodesis of the first metatarsophalangeal joint-biomechanical cadaver study comparing two methods of fixation
    Kunovsky, Radek
    Kocis, Jan
    Navrat, Tomas
    Vosynek, Petr
    Pink, Tomas
    Joukal, Marek
    Cizmar, Igor
    BIOMEDICAL PAPERS-OLOMOUC, 2022, 166 (03): : 334 - 342