Measurement of total antioxidant capacity of human plasma: Setting and validation of the CUPRAC-BCS method on routine apparatus ADVIA 2400

被引:17
|
作者
Gosmaro, Fabio [1 ]
Bagnati, Marco [2 ]
Berto, Silvia [1 ]
Bellomo, Giorgio [2 ]
Prenesti, Enrico [1 ]
机构
[1] Univ Turin, Dipartimento Chim, I-10125 Turin, Italy
[2] Univ Piemonte Orientate, Azienda Osped Maggiore Carita, Novara, Italy
关键词
Total antioxidant capacity; Oxidative stress; Human plasma; Method validation; RADICAL ABSORBENCY CAPACITY; OXIDATIVE STRESS; HUMAN SERUM; ASSAY; CROCIN; INDEX; ACID;
D O I
10.1016/j.talanta.2013.06.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Quantification of Total Antioxidant Capacity (TAC) of human plasma is an important clinical target, since many diseases are suspected to be related with oxidative stress. The CUPRAC-BCS (BCS =Bathocuproinedisulfonic acid) method was chosen since it works using the photometric principle, with stable and inexpensive reagents and at physiological pH. Methods: The method is based on the complex equilibria between Cu(II)-BCS (reagent) and Cu(I)-BCS. Cu (I)-BCS complex is formed by reducing ability of the plasma redox active substances. The photometric signal is achieved at 478 nm and calibration is performed using urate as a reference substance. Results: Linearity, linear working range, sensitivity, precision, LoD, LoQ selectivity and robustness have been considered to validate the method. Absorbance at 478 nm was found linear from 0.0025 up to 2.0 mmol L-1 of urate reference solution. Precision was evaluated as within-day repeatability, S-r=4 mu mol L-1, and intermediate-precision, S-I(T)=15 mu mol L-1. LoD and LoQ resulted equal to 7.0 mu mol L-1 and 21 mu mol L-1 respectively while robustness was tested having care for pH variation during PBS buffer preparation. Tests on plasma (80 samples) and on human cerebrospinal fluid (30 samples) were conducted and discussed. Conclusions: By the analytical point of view, the photometric method was found to be simple, rapid, widely linear and reliable for the routine analysis of a clinical laboratory. By the clinical point of view, the method response is suitable for the study of chemical plasma quantities related to redox reactivity. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:526 / 532
页数:7
相关论文
共 12 条
  • [1] Measurement uncertainty evaluation of the Total Antioxidant Capacity of human plasma tested by the CUPRAC-BCS method
    Prenesti, Enrico
    Berto, Silvia
    Gosmaro, Fabio
    Fisicaro, Paola
    Bagnati, Marco
    Bellomo, Giorgio
    MEASUREMENT, 2020, 152
  • [2] Dysmetabolisms Can Affect Total Antioxidant Capacity (TAC) of Human Plasma: Determination of Reference Intervals of TAC by Way of CUPRAC-BCS Method
    Prenesti, Enrico
    Berto, Silvia
    Gosmaro, Fabio
    Bagnati, Marco
    Bellomo, Giorgio
    ANTIOXIDANTS, 2021, 10 (01) : 1 - 10
  • [3] A novel total antioxidant capacity measurement for food and plasma antioxidants:: CUPRAC method
    Apak, R.
    Guclu, K.
    Ozyurek, M.
    Celik, S. E.
    FEBS JOURNAL, 2006, 273 : 72 - 72
  • [4] Evaluation of the copper(II) reduction assay using bathocuproinedisulfonic acid disodium salt for the total antioxidant capacity assessment: The CUPRAC-BCS assay
    Campos, Carlos
    Guzman, Rodrigo
    Lopez-Fernandez, Encarnacion
    Casado, Angela
    ANALYTICAL BIOCHEMISTRY, 2009, 392 (01) : 37 - 44
  • [5] Direct measurement of total antioxidant capacity of cereals: QUENCHER-CUPRAC method
    Tufan, Ayse Nur
    Celik, S. Esin
    Ozyurek, Mustafa
    Guclu, Kubilay
    Apak, Resat
    TALANTA, 2013, 108 : 136 - 142
  • [6] PROTEIN-INCORPORATED SERUM TOTAL ANTIOXIDANT CAPACITY MEASUREMENT BY A MODIFIED CUPRAC (CUPRIC REDUCING ANTIOXIDANT CAPACITY) METHOD
    Cekic, Sema Demirci
    Kara, Nilay
    Tutem, Esma
    Baskan, Kevser Sozgen
    Apak, Resat
    ANALYTICAL LETTERS, 2012, 45 (07) : 754 - 763
  • [7] Uncertainty estimation for total antioxidant capacity measurement of apple juice using main CUPRAC method
    Kilincer, Mehmet
    Cicek, Gulsum
    Ozyurek, Mustafa
    Apak, Resat
    JOURNAL OF CHEMICAL METROLOGY, 2022, 16 (01): : 28 - 37
  • [8] Total antioxidant capacity assay of human serum using copper(II)-neocuproine as chromogenic oxidant:: The CUPRAC method
    Apak, R
    Güçlü, K
    Özyürek, M
    Karademir, SE
    Altun, M
    FREE RADICAL RESEARCH, 2005, 39 (09) : 949 - 961
  • [9] Enhanced chemiluminescence assay vs colorimetric assay for measurement of the total antioxidant capacity of human seminal plasma
    Said, TM
    Kattal, N
    Sharma, RK
    Sikka, SC
    Thomas, AJ
    Mascha, E
    Agarwal, A
    JOURNAL OF ANDROLOGY, 2003, 24 (05): : 676 - 680
  • [10] A microplate-based spectrophotometric method for the determination of total antioxidant capacity of human plasma: modified cupric reducing ability assay
    Usanmaz, S. E.
    Yilmaz, E. D.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2008, 22 : 67 - 67