Capillary model of crystal microchannel for red blood cell deformability measurement

被引:0
|
作者
Tsukada, K [1 ]
Sekizuka, E [1 ]
Oshio, C [1 ]
Nagai, T [1 ]
Minamitani, H [1 ]
机构
[1] Keio Univ, Fac Sci & Technol, Inst Biomed Engn, Kohoku Ku, Yokohama, Kanagawa 223, Japan
来源
PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING | 1997年 / 19卷
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To measure red blood cell (RBC) deformability in vitro, we used microchannels on a crystal substrate as a capillary model. We observed axisymmetry deformed RBCs to estimate their deformability and decided deformability index directly from RBCs themselves. The flowing RBCs in 200 folds through microscopy were recorded with an image-intensified high speed video camera system. This system allowed us to record individual RBC images clearly. We confirmed that the crystal microchannel is a valuable tool for RBC deformability measurement. Microangiopathy is a characteristic complication of diabetes mellitus. The decrease of RBC deformability is thought to cause this complication. In order to identify the deference in RBCs deformability between normal and diabetic RBCs. We could confirm that deformability of diabetic RBCs were much lower than normal ones, and this result suggests a possibility of serious damage in diabetic microcirculation.
引用
收藏
页码:2375 / 2376
页数:2
相关论文
共 50 条
  • [1] RED CELL DEFORMABILITY AND CAPILLARY BLOOD FLOW
    BRAASCH, D
    PHYSIOLOGICAL REVIEWS, 1971, 51 (04) : 679 - &
  • [2] The Flow Behavior of Red Blood Cell Reduced Deformability in Microchannel
    Fen Li
    Rui Duan
    Hui Li
    医用生物力学, 2019, 34(S1) (S1) : 116 - 117
  • [3] A METHOD FOR THE MEASUREMENT OF THE RED-BLOOD-CELL DEFORMABILITY
    KIESEWETTER, H
    DAUER, U
    GESCH, M
    SEIFFGE, D
    ANGELKORT, B
    SCHMIDSCHONBEIN, H
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1981, 41 : 229 - 232
  • [4] Red blood cell-deformability measurement: Review of techniques
    Musielak, M.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2009, 42 (01) : 47 - 64
  • [5] Electrical measurement of red blood cell deformability on a microfluidic device
    Zheng, Yi
    Nguyen, John
    Wang, Chen
    Sun, Yu
    LAB ON A CHIP, 2013, 13 (16) : 3275 - 3283
  • [6] Multiplexed fluidic plunger mechanism for the measurement of red blood cell deformability
    Myrand-Lapierre, Marie-Eve
    Deng, Xiaoyan
    Ang, Richard R.
    Matthews, Kerryn
    Santoso, Aline T.
    Ma, Hongshen
    LAB ON A CHIP, 2015, 15 (01) : 159 - 167
  • [7] Measurement of the distribution of red blood cell deformability using an automated rheoscope
    Dobbe, JGG
    Streekstra, GJ
    Hardeman, MR
    Ince, C
    Grimbergen, CA
    CYTOMETRY, 2002, 50 (06): : 313 - 325
  • [8] Electrical classification of single red blood cell deformability in high-shear microchannel flows
    Katsumoto, Yoichi
    Tatsumi, Kazuya
    Doi, Tatsuki
    Nakabe, Kazuyoshi
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2010, 31 (06) : 985 - 995
  • [9] Red blood cell deformability in sepsis
    Baskurt, OK
    Gelmont, D
    Meiselman, HJ
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 157 (02) : 421 - 427
  • [10] Capillary recruitment in response to tissue hypoxia and its dependence on red blood cell deformability
    Parthasarathi, K
    Lipowsky, HH
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1999, 277 (06): : H2145 - H2157