Rapid drug detection in oral samples by porous silicon assisted laser desorption/ionization mass spectrometry

被引:24
|
作者
Lowe, Rachel D. [1 ]
Guild, Georgia E. [1 ]
Harpas, Peter [2 ]
Kirkbride, Paul [3 ]
Hoffmann, Peter [4 ]
Voelcker, Nicolas H. [1 ]
Kobus, Hilton [1 ]
机构
[1] Flinders Univ S Australia, Sch Chem Phys & Earth Sci, Bedford Pk, SA 5042, Australia
[2] Forens Sci S Australia, Adelaide, SA 5001, Australia
[3] Australian Fed Police, Canberra, ACT 2601, Australia
[4] Univ Adelaide, Adelaide Prote Ctr, Sch Med & Biomed Sci, Adelaide, SA 5005, Australia
基金
澳大利亚研究理事会;
关键词
INJURED DRIVERS; ILLICIT DRUGS; DESORPTION-IONIZATION; QUANTITATIVE-ANALYSIS; GAS-CHROMATOGRAPHY; COLLECTION DEVICE; FLUID COLLECTION; PART II; ABUSE; ALCOHOL;
D O I
10.1002/rcm.4284
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The demand for analysis of oral fluid for illicit drugs has arisen with the increased adoption of roadside testing, particularly in countries where changes in legislation allow random roadside testing of drivers for the presence of a palette of illicit drugs such as methamphetamine (MA), 3,4-methylenedioxymethamphetamine (MDMA) and Delta(9)-tetrahydrocannabinol (THC). Oral samples are currently tested for such drugs at the roadside using an immunoassay-based commercial test kit. Positive roadside tests are sent for confirmatory laboratory analysis, traditionally by means of gas chromatography/mass spectrometry (GC/MS). We present here an alternative rapid analysis technique, porous silicon assisted laser desorption/ionization time-of-flight mass spectrometry (pSi LDI-MS), for the high-throughput analysis of oral fluids. This technique alleviates the need for sample derivatization, requires only sub-microliter sample volumes and allows fast analysis (of the order of seconds). In this study, the application of the technique is demonstrated with real samples from actual roadside testing. The analysis of oral samples resulted in detection of MA and MDMA with no extraction and analysis of THC after ethyl acetate extraction. We propose that, subject to miniaturization of a suitable mass spectrometer, this technique is well suited to underpin the deployment of oral fluid testing in the clinic, workplace and on the roadside. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:3543 / 3548
页数:6
相关论文
共 50 条
  • [1] Desorption/ionization mass spectrometry on porous silicon
    Zhang, QC
    Zou, HF
    Zhang, Q
    Guo, Z
    Jiang, HH
    Ni, JY
    Chen, XM
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (12) : 1365 - 1369
  • [2] Desorption–ionization mass spectrometry on porous silicon
    Jing Wei
    Jillian M. Buriak
    Gary Siuzdak
    Nature, 1999, 399 : 243 - 246
  • [3] Combined Immunocapture and Laser Desorption/Ionization Mass Spectrometry on Porous Silicon
    Lowe, Rachel D.
    Szili, Endre J.
    Kirkbride, Paul
    Thissen, Helmut
    Siuzdak, Gary
    Voelcker, Nicolas H.
    ANALYTICAL CHEMISTRY, 2010, 82 (10) : 4201 - 4208
  • [4] Porous silicon as a versatile platform for laser desorption/ionization mass spectrometry
    Shen, ZX
    Thomas, JJ
    Averbuj, C
    Broo, KM
    Engelhard, M
    Crowell, JE
    Finn, MG
    Siuzdak, G
    ANALYTICAL CHEMISTRY, 2001, 73 (03) : 612 - 619
  • [5] Effective detection of peptides containing cysteine sulfonic acid using matrix-assisted laser desorption/ionization and laser desorption/ionization on porous silicon mass spectrometry
    Kinumi, T
    Shimomae, Y
    Arakawa, R
    Tatsu, Y
    Shigeri, Y
    Yumoto, N
    Niki, E
    JOURNAL OF MASS SPECTROMETRY, 2006, 41 (01): : 103 - 112
  • [6] Desorption-ionization mass spectrometry on porous silicon
    Wei, J
    Buriak, JM
    Siuzdak, G
    NATURE, 1999, 399 (6733) : 243 - 246
  • [7] Desorption-ionization mass spectrometry on porous silicon
    Depts. of Molec. Biol. and Chemistry, Scripps Research Institute, BCC157, 10550 North Torrey Pines Road, San Diego, CA 92037, United States
    不详
    Nature, 6733 (243-246):
  • [8] Desorption/ionization mass spectrometry on porous silicon dioxide
    Górecka-Drzazga, A
    Bargiel, S
    Walczak, R
    Dziuban, JA
    Kraj, A
    Dylag, T
    Silberring, J
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 103 (1-2) : 206 - 212
  • [9] Silicon surface assisted laser desorption ionization mass spectrometry for quantitative analysis
    Grechnikov, Alexander A.
    Borodkov, Alexey S.
    Simanovsky, Yaroslav O.
    Nikiforov, Sergey M.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2021, 27 (2-4) : 84 - 93
  • [10] Improving the Detection Performance of Surface-assisted Laser Desorption/ionization Mass Spectrometry by Silicon Nanostructures
    Dou Shuzhen
    Wang Zhongshun
    Lyu Nan
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2021, 42 (04): : 1156 - 1166