Implementation of a piecewise-linear dynamic attenuator

被引:2
|
作者
Shunhavanich, Picha [1 ,2 ]
Bennett, Nathaniel Robert [2 ]
Hsieh, Scott S. [3 ]
Pelc, Norbert J. [1 ,2 ]
机构
[1] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[3] Univ Calif Los Angeles, Dept Radiol Sci, Los Angeles, CA 90024 USA
基金
美国国家卫生研究院;
关键词
dynamic bowtie filter; fluence field modulation; dynamic range reduction; photon counting detector; CT;
D O I
10.1117/1.JMI.6.2.023502
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A dynamic prepatient attenuator can modulate flux in a computed tomography (CT) system along both fan and view angles for reduced dose, scatter, and required detector dynamic range. Reducing the dynamic range requirement is crucial for photon counting detectors. One approach, the piecewise-linear attenuator (Hsieh and Pelc, Med Phys 2013), has shown promising results both in simulations and an initial prototype. Multiple wedges, each covering a different fan angle range, are moved in the axial direction to change thickness seen in an axial slice. We report on an implementation of a filter with precision components and a control algorithm targeted for a tabletop system. Algorithms for optimizing wedge position and mA modulation and for correcting bowtie-specific beam-hardening are proposed. In experiments, the error between expected and observed bowtie transmission was similar to 2% on average and similar to 7% at maximum for a chest phantom. Within object boundaries, the observed flux dynamic ranges of 42 for a chest and 25 for an abdomen were achieved, corresponding to a reduction factor of 5 and 11 from the object scans without the bowtie. With beam hardening correction, the CT number in soft tissue regions was improved by 79 HU and deviated by 7 HU on average from clinical scanner CT images. The implemented piecewise-linear attenuator is able to dynamically adjust its thickness with high precision to achieve flexible flux control. (C) 2019 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Implementation of a Piecewise-linear Dynamic Attenuator
    Shunhavanich, Picha
    Bennett, N. Robert
    Hsieh, Scott S.
    Pelc, Norbert J.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [2] A prototype piecewise-linear dynamic attenuator
    Hsieh, Scott S.
    Peng, Mark V.
    May, Christopher A.
    Shunhavanich, Picha
    Fleischmann, Dominik
    Pelc, Norbert J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (13): : 4974 - 4988
  • [3] Dose reduction using a dynamic, piecewise-linear attenuator
    Hsieh, Scott S.
    Fleischmann, Dominik
    Pelc, Norbert J.
    MEDICAL PHYSICS, 2014, 41 (02)
  • [4] IMPLEMENTATION OF PIECEWISE-LINEAR FUZZY QUANTITIES
    STEYAERT, H
    VANPARYS, F
    BAEKELAND, R
    KERRE, EE
    INTERNATIONAL JOURNAL OF INTELLIGENT SYSTEMS, 1995, 10 (12) : 1049 - 1059
  • [5] On the dynamic analysis of piecewise-linear networks
    Heemels, WPMH
    Çamlibel, MK
    Schumacher, JM
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2002, 49 (03) : 315 - 327
  • [6] The piecewise-linear dynamic attenuator reduces the impact of count rate loss with photon-counting detectors
    Hsieh, Scott S.
    Pelc, Norbert J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (11): : 2829 - 2847
  • [7] Implementation of piecewise-linear DC analysis in APLAC
    Roos, J
    Valtonen, M
    Virtanen, J
    ICES 2002: 9TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS I-111, CONFERENCE PROCEEDINGS, 2002, : 1139 - 1142
  • [8] A Piecewise-Linear Model of Intracranial Pressure Dynamic
    Evans, D.
    Drapaca, C.
    Cusumano, J. P.
    X INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS (EURODYN 2017), 2017, 199 : 595 - 600
  • [9] Piecewise-linear soliton equations and piecewise-linear integrable maps
    Quispel, GRW
    Capel, HW
    Scully, J
    JOURNAL OF PHYSICS A-MATHEMATICAL AND GENERAL, 2001, 34 (11): : 2491 - 2503
  • [10] The feasibility of a piecewise-linear dynamic bowtie filter
    Hsieh, Scott S.
    Pelc, Norbert J.
    MEDICAL PHYSICS, 2013, 40 (03)