Influence of adhesive application duration on dentin bond strength of single-application bonding systems

被引:0
|
作者
Miyazaki, M [1 ]
Tsubota, K [1 ]
Onose, H [1 ]
Hinoura, K [1 ]
机构
[1] Nihon Univ, Sch Med, Dept Operat Dent, Tokyo, Japan
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study examined the relationship between the bond agent application duration and the dentin bond strength of several single-application bonding systems. The restorative material/bonding systems used were Reactmer, with its single-application bonding system Reactmer Bond (RB, Shofu Inc, Kyoto, Japan); Palfique Estelite, with its single-application bonding system One-Up Bond F (OU, Tokuyama Co, Tokyo, Japan) and F2000 Compomer, with its bonding system Primer/Adhesive in Clicker (F2, 3M Dental Products, St Paul, MN 55144, USA). Bovine mandibular incisors were mounted in self-curing resin and wet ground with #600 SiC to expose labial dentin. Adhesives were applied for 5, 10, 20, 30 and 60 seconds, and restorative materials were condensed into a Teflon mold (O4 x 2 mm) on the dentin and light activated. Fifteen samples per test group were stored in 37degreesC water for 24 hours, then shear tested at a crosshead speed of 1.0 mm/min. One-way ANOVA followed by Duncan test (p=0.05) was done. SEM observations of the treated dentin surface were also conducted. The dentin bond strength ranged from 6.9+/-2.4 to 11.2+/-2.8 MPa for RB, 8.9+/-2.2 to 12.2+/-1.9 MPa for OU, and 7.8+/-3.1 to 11.4+/-2.6 MPa for F2. No significant differences were found among the 10-60 second application duration groups for the systems used. From the SEM observations, demineralization of the dentin surface was more pronounced with longer application duration. The data suggest that the duration of single-application bonding systems was not a crucial factor for determining dentin bond strength, even though morphological changes were observed on the dentin surface.
引用
收藏
页码:278 / 283
页数:6
相关论文
共 50 条
  • [1] Influence of delayed placement of composites over cured adhesives on dentin bond strength of single-application self-etch systems
    Asaka, Y
    Miyazaki, M
    Takamizawa, T
    Tsubota, K
    Moore, BK
    OPERATIVE DENTISTRY, 2006, 31 (01) : 18 - 24
  • [2] Influence of Application Methods of Self-etching Adhesive Systems on Adhesive Bond Strength to Dentin
    Pleffken, Patricia Rondon
    de Almeida Lourenco, Ana Paula
    Gomes Torres, Carlos Rocha
    Borges, Alessandra Buehler
    JOURNAL OF ADHESIVE DENTISTRY, 2011, 13 (06): : 517 - 525
  • [3] Enamel and dentin bond strengths of single application bonding systems
    Miyazaki, M
    Iwasaki, K
    Onose, H
    Moore, BK
    AMERICAN JOURNAL OF DENTISTRY, 2001, 14 (06): : 361 - 366
  • [4] Influence of additional adhesive application on the microtensile bond strength of adhesive systems
    Silva, A. L. F.
    Lima, D. A. N. L.
    Souza, G. M. D.
    Santos, C. T. D.
    Paulillo, L. A. M. S.
    OPERATIVE DENTISTRY, 2006, 31 (05) : 562 - 568
  • [5] Influence of adhesive application method and thermocycling on the bonding performance of different adhesive systems to dentin
    Moharam, Lamiaa
    Afifi, Rasha
    JOURNAL OF INTERNATIONAL ORAL HEALTH, 2023, 15 (02): : 168 - 173
  • [6] Bond Strength of Resin Composite to Dentin with Different Adhesive Systems: Influence of Relative Humidity and Application Time
    Amsler, Fabienne
    Peutzfeldt, Anne
    Lussi, Adrian
    Flury, Simon
    JOURNAL OF ADHESIVE DENTISTRY, 2015, 17 (03): : 249 - 256
  • [7] Evaluation of Bond Strength of Self-adhesive Cements to Dentin With or Without Application of Adhesive Systems
    Barcellos, Daphne Camara
    Batista, Graziela Ribeiro
    da Silva, Melissa Aline
    Rangel, Patricia Maria
    Gomes Torres, Carlos Rocha
    Fava, Marcelo
    JOURNAL OF ADHESIVE DENTISTRY, 2011, 13 (03): : 261 - 265
  • [8] Effect of air-drying time of single-application self-etch adhesives on dentin bond strength
    Chiba, Y
    Yamaguchi, K
    Miyazaki, M
    Tsubota, K
    Takamizawa, T
    Moore, BK
    OPERATIVE DENTISTRY, 2006, 31 (02) : 233 - 239
  • [9] Influence of powdered dentin on the shear bond strength of dentin bonding systems
    Dalkilic, Evrim Eliguzeloglu
    Genc, Ozgur
    Ozcopur, Betul
    Belli, Sema
    Eskitascioglu, Gurcan
    Oezcan, Mutlu
    DENTAL MATERIALS JOURNAL, 2012, 31 (05) : 758 - 764
  • [10] Influence of Blood Contamination During Multimode Adhesive Application on the Microtensile Bond Strength to Dentin
    Kucukyilmaz, E.
    Celik, E. U.
    Akcay, M.
    Yasa, B.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2017, 20 (12) : 1644 - 1650