Custom-fit minimally invasive total knee arthroplasty: effect on blood loss and early clinical outcomes

被引:41
|
作者
Pietsch, M. [1 ]
Djahani, O. [1 ]
Zweiger, Ch [1 ]
Plattner, F. [1 ]
Radl, R. [1 ]
Tschauner, Ch [1 ]
Hofmann, S. [1 ]
机构
[1] Gen & Orthopaed Hosp Stolzalpe, Dept Orthopaed Surg, A-8852 Stolzalpe, Austria
关键词
Custom-fit; Patient specific instruments; Blood loss; Clinical outcomes; Total knee arthroplasty; INITIAL-EXPERIENCE; HIP-ARTHROPLASTY; SURGERY; INSTRUMENTATION; REPLACEMENT; MANAGEMENT; NAVIGATION; ANESTHESIA; INCISION; IMPROVE;
D O I
10.1007/s00167-012-2284-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Recently, new custom-fit pin guides in total knee arthroplasty (TKA) have been introduced. Use of these guides may reduce operating time. Use of the guides combined with the absence of intramedullary alignment jigs may lead to reduced blood loss and improved early outcomes. Our aim was to evaluate blood loss and early clinical outcomes in patients undergoing minimally invasive TKA using custom-fit magnetic resonance imaging (MRI)-based pin guides. A prospective study in 80 patients was carried out. Patients were divided randomly into 2 equal groups. In one group, intramedullary alignment jigs were used. In the second group, custom-fit MRI-based pin guides were used. All patients received the same cemented posterior-stabilized implant through a mini-midvastus approach. The volume in the drain bottles was recorded after 48 h. Hb loss was estimated by subtracting the postoperative from the preoperative Hb level. Transfusion requirements and surgical time were recorded. Outcome measures were Knee Society Scores (KSS), knee flexion, knee swelling and pain. There was lower mean drainage of blood in the custom-fit group (391 ml vs. 603 ml; p < 0.0001). There was no difference in estimated loss of Hb (3.6 g/dl vs. 4.1 g/dl; n.s.) and in transfusion requirements (7.5 % vs. 10 %; n.s.). Surgical time was reduced in the custom-fit group (12 min less; p = 0.001). KSS measured at week 2, 6 and 12 showed no significant difference between groups. Knee flexion measured on days 7, 10 and at week 6, 12 and knee swelling and pain measured on days 1, 3, 10 and at week 6, 12 showed no significant difference between groups. Using custom-fit pin guides reduces blood drainage, but not the estimated Hb loss in minimally invasive TKA and does not affect transfusion rate. Surgical time is reduced. There is no effect on the early clinical outcomes. Therapeutic study, Level I.
引用
收藏
页码:2234 / 2240
页数:7
相关论文
共 50 条
  • [1] Custom-fit minimally invasive total knee arthroplasty: effect on blood loss and early clinical outcomes
    M. Pietsch
    O. Djahani
    Ch. Zweiger
    F. Plattner
    R. Radl
    Ch. Tschauner
    S. Hofmann
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2234 - 2240
  • [2] Bilateral Custom-fit Total Knee Arthroplasty in a Patient With Poliomyelitis
    Tardy, Nicolas
    Chambat, Pierre
    Murphy, Colin G.
    Fayard, Jean-Marie
    ORTHOPEDICS, 2014, 37 (09) : e839 - e843
  • [3] Custom-fit total knee arthroplasty (OtisKnee) results in malalignment
    Klatt, Brian A.
    Goyal, Nitin
    Austin, Matthew S.
    Hozack, William J.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (01): : 26 - 29
  • [4] Custom-Fit Total Knee Arthroplasty: Our Initial Experience in 32 Knees
    Bali, Kamal
    Walker, Peter
    Bruce, Warwick
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 1149 - 1154
  • [5] Custom-fit total knee arthroplasty: Our initial experience with 30 knees
    Bonicoli E.
    Andreani L.
    Parchi P.
    Piolanti N.
    Lisanti M.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (7) : 1249 - 1254
  • [6] MRI enables custom-fit total knee replacement
    不详
    ADVANCED MATERIALS & PROCESSES, 2008, 166 (01): : 73 - 73
  • [7] Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients
    Howell, Stephen M.
    Kuznik, Kyle
    Hull, Maury L.
    Siston, Robert A.
    ORTHOPEDICS, 2008, 31 (09) : 857 - 863
  • [8] Custom-fit kinematic alignment in total knee arthroplasty using PSI. The story of ShapeMatch technology
    Calliess, T.
    Ettinger, M.
    Stukenborg-Colsmann, C.
    Windhagen, H.
    ORTHOPADE, 2016, 45 (04): : 314 - +
  • [9] Blood loss after navigation-assisted minimally invasive total knee arthroplasty
    Eum, Dae Sub
    Lee, Ho Kyu
    Hwang, Seok Young
    Park, Jin Uck
    ORTHOPEDICS, 2006, 29 (10) : S152 - S154
  • [10] BLOOD LOSS AFTER MINIMALLY INVASIVE TOTAL KNEE ARTHROPLASTY: EFFECTS OF IMAGELESS NAVIGATION
    Chang, Chih-Wei
    Wu, Po-Ting
    Yang, Chyun-Yu
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2010, 26 (05): : 237 - 242