Left ventricular assist systems and infection-related outcomes: A comprehensive analysis of the MOMENTUM 3 trial

被引:60
|
作者
Patel, Chetan B. [1 ]
Blue, Laura [1 ]
Cagliostro, Barbara [2 ]
Bailey, Stephen H. [3 ]
Entwistle, John W. [4 ]
John, Ranjit [5 ]
Thohan, Vinay [6 ]
Cleveland, Joseph C. [7 ]
Goldstein, Daniel J. [8 ]
Uriel, Nir [2 ]
Su, Xiaolu [9 ]
Somo, Sami I. [9 ]
Sood, Poornima [9 ]
Mehra, Mandeep R. [10 ,11 ]
机构
[1] Duke Univ, Med Ctr, Durham, NC USA
[2] Columbia Univ, Med Ctr, New York Presbyterian, New York, NY USA
[3] Allegheny Gen Hosp, Pittsburgh, PA 15212 USA
[4] Thomas Jefferson Univ Hosp, Philadelphia, PA 19107 USA
[5] Univ Minnesota, Med Ctr, Minneapolis, MN 55455 USA
[6] Mission Hlth Syst, Asheville, NC USA
[7] Univ Colorado, Sch Med, Aurora, CO USA
[8] Montefiore Einstein Ctr Heart & Vasc Care, New York, NY USA
[9] Abbott, Abbott Pk, IL USA
[10] Brigham & Womens Hosp, 75 Francis St, Boston, MA 02115 USA
[11] Harvard Med Sch, Boston, MA 02115 USA
来源
关键词
LVAD; infection; prognosis; driveline; MCS; heart failure; DEVICE; IMPLANTATION; IMPACT;
D O I
10.1016/j.healun.2020.03.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: In a randomized controlled trial (MOMENTUM 3), the HeartMate 3 (HM3) fully magnetically levitated centrifugal-flow left ventricular assist device (LVAD) demonstrated superiority over the HeartMate II (HMII) axial-flow LVAD. These findings were driven by hemocompatibility-related outcomes, but infection-related outcomes were not altered by device choice. In this trial-level analysis, we analyzed the clinical patterns of infection-related outcomes over 2 years of support. METHODS: In MOMENTUM 3, 1,020 patients were implanted with either the HM3 (n = 515) or HMII (n = 505) pump. Clinical characteristics and morbidity-and mortality-related outcomes were evaluated to identify predictors associated with major infectious complications, using univariable and multivariable models. RESULTS: The cumulative number of infections at 2 years was 1,213 (634 HM3 and 579 HMII), and major infection occurred in 58% of patients with the HM3 and 56% of patients with the HMII (p = 0.57). Infections of a local nature unrelated to pump components were most common (n = 681/1,213; 56%), followed by driveline-associated infection (n = 329/1,213; 27%), sepsis (n = 194/1,213; 16%), and other events (n = 9/1,213; 0.7%). Bacterial pathogens were implicated in 806 of 1,213 events (66%); significant predictors of infection included sex (women vs men; hazard ratio [HR]: 1.38, p = 0.003), pre-implant use of intra-aortic balloon pump (HR: 1.33, p = 0.02), pre-implant history of cardiac surgery (HR: 1.28, p = 0.01), and body mass index >= 30 (HR: 1.40, p < 0.0001). Most deaths in those with infection occurred owing to non-infectious causes. CONCLUSION: Infection is the most common adverse effect in patients implanted with contemporary continuous-flow LVADs, with most such events unrelated to the pump or its peripheral components. Whether chronic mechanical circulatory devices confer an immunomodulatory effect pre-disposing to infection warrants closer scrutiny to understand and ameliorate this morbidity. J Heart Lung Transplant 2020;39:774-781 (C) 2020 The Author(s). Published by Elsevier Inc. on behalf of International Society for Heart and Lung Transplantation. This is an open access article under the CC BY-NC-ND license. (http://creativecommons.org/licenses/by-nc-nd/4.0)
引用
收藏
页码:774 / 781
页数:8
相关论文
共 50 条
  • [1] Infection-Related Morbidity with Continuous-Flow Left Ventricular Assist Systems: A Comprehensive Analysis of the Randomized MOMENTUM 3 Trial
    Patel, C. B.
    Bailey, S. H.
    Blue, L.
    Cagliostro, B.
    Entwistle, J. W.
    John, R.
    Thohan, V.
    Su, X.
    Somo, S. I.
    Sood, P.
    Mehra, M. R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S45 - S45
  • [2] The Impact of MOMENTUM 3 Trial Eligibility on Left Ventricular Assist Device Outcomes: A Real-World Experience
    George, Timothy J.
    Kabra, Nitin
    DiMaio, J. Michael
    Rawitscher, David A.
    Afzal, Aasim
    JOURNAL OF SURGICAL RESEARCH, 2023, 287 : 40 - 46
  • [3] Impact of left ventricular assist device implantation on mitral regurgitation: An analysis from the MOMENTUM 3 trial
    Kanwar, Manreet K.
    Rajagopal, Keshava
    Itoh, Akinobu
    Silvestry, Scott C.
    Uriel, Nir
    Cleveland, Joseph C., Jr.
    Salerno, Christopher T.
    Horstmanshof, Douglas
    Goldstein, Daniel J.
    Naka, Yoshifumi
    Bailey, Stephen
    Gregoric, Igor D.
    Chuang, Joyce
    Sood, Poornima
    Mehra, Mandeep R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (06): : 529 - 537
  • [4] Effect of aspirin dose on hemocompatibility-related outcomes with a magnetically levitated left ventricular assist device: An analysis from the MOMENTUM 3
    Saeed, Omar
    Colombo, Paolo C.
    Mehra, Mandeep R.
    Uriel, Nir
    Goldstein, Daniel J.
    Cleveland, Joseph
    Connors, Jean M.
    Najjar, Samer S.
    Mokadam, Nahush A.
    Bansal, Aditya
    Crandall, Daniel L.
    Sood, Poornima
    Jorde, Ulrich P.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (06): : 518 - 525
  • [5] Anticoagulation Bridging In Patients With Heartmate3 Left Ventricular Assist Device: A Regional Analysis Of The Momentum 3 Trial
    Yaranov, Dmitry M.
    Baldridge, Abigail S.
    Chaudhry, Sunit-Preet
    Gonzalez, Matthew
    Biglane, J. Barr
    Tanaka, Daizo
    Fischer, William
    Larkin, Chris
    Ullah, Rafath
    Pham, Duc
    JOURNAL OF CARDIAC FAILURE, 2023, 29 (04) : 609 - 609
  • [6] Impact of Race on Clinical Outcomes After Implantation With a Fully Magnetically Levitated Left Ventricular Assist Device An Analysis From the MOMENTUM 3 Trial
    Sheikh, Farooq H.
    Ravichandran, Ashwin K.
    Goldstein, Daniel J.
    Agarwal, Richa
    Ransom, John
    Bansal, Aditya
    Kim, Gene
    Cleveland, Joseph C.
    Uriel, Nir
    Sheridan, Brett C.
    Chomsky, Don
    Patel, Snehal R.
    Dirckx, Nick
    Franke, Abi
    Mehra, Mandeep R.
    CIRCULATION-HEART FAILURE, 2021, 14 (10) : 1083 - 1094
  • [7] Outcomes of Heart Transplant After Left Ventricular Assist Device Specific and Related Infection
    Tong, Michael Z.
    Smedira, Nicholas G.
    Soltesz, Edward G.
    Starling, Randall C.
    Koval, Christine E.
    Porepa, Liane
    Moazami, Nader
    ANNALS OF THORACIC SURGERY, 2015, 100 (04): : 1292 - 1297
  • [8] Clinical Predictors of 5-year Outcomes Following Heartmate 3 Left Ventricular Assist Device Implant: The Momentum 3 Trial
    Nayak, A.
    Hall, S.
    Uriel, N.
    Goldstein, D.
    Cleveland, J.
    Cowger, J.
    Salerno, C.
    Naka, Y.
    Horstmanshof, D.
    Somo, S.
    Wang, A.
    Mehra, M. R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2023, 42 (04): : S88 - S89
  • [9] Retrospective analysis of infection in patients undergoing support with left ventricular assist systems
    Springer, WE
    Wasler, A
    Radovancevic, B
    Myers, T
    Odegaard, P
    Macris, MP
    Frazier, OH
    ASAIO JOURNAL, 1996, 42 (05) : M763 - M765
  • [10] Clinical Outcomes of Left Ventricular Assist Device Pump Infection
    Imaoka, Shusuke
    Samura, Takaaki
    Yoshioka, Daisuke
    Kawamura, Masashi
    Kawamura, Takuji
    Toda, Koichi
    Miyagawa, Shigeru
    ASAIO JOURNAL, 2023, 69 (12) : 1056 - 1064