Modeling ventilation in naturally ventilated double-skin facade with a venetian blind

被引:53
|
作者
Zeng, Zhen [1 ]
Li, Xiaofeng [1 ]
Li, Cheng [1 ]
Zhu, Yingxin [1 ]
机构
[1] Tsinghua Univ, Sch Architecture, Dept Bldg Sci, Beijing 100084, Peoples R China
关键词
Naturally ventilated double-skin facade; Venetian blind; Computational fluid dynamics; Porous media model; Field experiments; GLASS DOUBLE FACADES; PERFORMANCE; CONVECTION; SIMULATION; DEVICE; TOOL;
D O I
10.1016/j.buildenv.2012.04.007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Double-skin facade (DSF) is widely used in commercial buildings, and naturally ventilated DSF with venetian blinds is the most common type in hot summer and cold winter areas. However, economical and practical computational fluid dynamics (CFD) methods suitable for modeling ventilation in naturally ventilated DSF with venetian blinds have not yet been developed, due to the complicated influence of meteorological conditions and the large number of meshes near the venetian blind slats in CFD models. In this paper, the CFD method using a porous media model is proposed to solve this problem. Both the driven forces of thermal buoyancy and wind pressure were taken into account in the CFD simulations. Field experiments were performed for validation. The porous media model showed good computational accuracy, and at the same time, greatly reduced the mesh number and computing time, compared with the explicit slat model. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [1] Naturally ventilated double-skin facade in modeling and experiments
    Dama, Alessandro
    Angeli, Diego
    Larsen, Olena Kalyanova
    ENERGY AND BUILDINGS, 2017, 144 : 17 - 29
  • [2] Ventilation performance of a naturally ventilated double-skin facade in buildings
    Tao, Yao
    Zhang, Haihua
    Zhang, Lili
    Zhang, Guomin
    Tu, Jiyuan
    Shi, Long
    RENEWABLE ENERGY, 2021, 167 : 184 - 198
  • [3] Naturally ventilated double-skin facade with adjustable louvers
    Tao, Yao
    Fang, Xiang
    Setunge, Sujeeva
    Tu, Jiyuan
    Liu, Jingcheng
    Shi, Long
    SOLAR ENERGY, 2021, 225 : 33 - 43
  • [4] Experimental and numerical analysis of a naturally ventilated double-skin facade
    Souza, L. C. O.
    Souza, H. A.
    Rodrigues, E. F.
    ENERGY AND BUILDINGS, 2018, 165 : 328 - 339
  • [5] Natural ventilation in the double skin facade with venetian blind
    Xu, Xiao-li
    Yang, Zhao
    ENERGY AND BUILDINGS, 2008, 40 (08) : 1498 - 1504
  • [6] CFD modelling of naturally ventilated double-skin facades with venetian blinds
    Institute of Energy and Sustainable Development, De Montfort University, Leicester, United Kingdom
    不详
    不详
    J. Build. Perform. Simul., 2008, 3 (185-196):
  • [7] Modeling and Simulation of Ventilated Double-Skin Facade Using EnergyPlus
    Le, Sha
    Chen, Youming
    Bi, Yuan
    Lu, Xiang
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 3: BUILDING SIMULATION AND INFORMATION MANAGEMENT, 2014, 263 : 241 - 252
  • [8] Coupling TRNSYS 17 and CONTAM: simulation of a naturally ventilated double-skin facade
    Khalifa, Ines
    Ernez, Leila Gharbi
    Znouda, Essia
    Bouden, Chiheb
    ADVANCES IN BUILDING ENERGY RESEARCH, 2015, 9 (02) : 293 - 304
  • [9] Application of compact silencers as a noise barrier to a naturally ventilated double-skin facade
    Lee, Jeehwan
    Chang, Jae D.
    Coffeen, Robert
    NOISE CONTROL ENGINEERING JOURNAL, 2021, 69 (03) : 220 - 228
  • [10] Natural ventilation in a double-skin facade
    Gratia, E
    De Herde, A
    ENERGY AND BUILDINGS, 2004, 36 (02) : 137 - 146