Development of Subject Specific Finite Element Models of the Mouse Knee Joint for Preclinical Applications

被引:6
|
作者
Zanjani-Pour, Sahand [1 ,2 ]
Giorgi, Mario [2 ,3 ]
Dall'Ara, Enrico [1 ,2 ]
机构
[1] Univ Sheffield, Mellanby Ctr Bone Res, Dept Oncol & Metab, Sheffield, S Yorkshire, England
[2] Univ Sheffield, Insigneo Inst In Silico Med, Sheffield, S Yorkshire, England
[3] Cetera UK Ltd, Simcyp Div, Cettara Quantitat Syst Pharmacol, Sheffield, S Yorkshire, England
基金
英国工程与自然科学研究理事会; 英国国家替代、减少和改良动物研究中心;
关键词
mouse knee; finite element; subject specific; PTA staining; cartilage; bone; ARTICULAR-CARTILAGE; OSTEOARTHRITIS; DESTABILIZATION; PREVALENCE; PATTERNS; MICROCT; STRAIN;
D O I
10.3389/fbioe.2020.558815
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Osteoarthritis is the most common musculoskeletal disabling disease worldwide. Preclinical studies on mice are commonly performed to test new interventions. Finite element (FE) models can be used to study joint mechanics, but usually simplified geometries are used. The aim of this project was to create a realistic subject specific FE model of the mouse knee joint for the assessment of joint mechanical properties. Four different FE models of a C57Bl/6 female mouse knee joint were created based on micro-computed tomography images of specimens stained with phosphotungstic acid in order to include different features: individual cartilage layers with meniscus, individual cartilage layers without meniscus, homogeneous cartilage layers with two different thickness values, and homogeneous cartilage with same thickness for both condyles. They were all analyzed under compressive displacement and the cartilage contact pressure was compared at 0.3 N reaction force. Peak contact pressure in the femur cartilage was 25% lower in the model with subject specific cartilage compared to the simpler model with homogeneous cartilage. A much more homogeneous pressure distribution across the joint was observed in the model with meniscus, with cartilage peak pressure 5-34% lower in the two condyles compared to that with individual cartilage layers. In conclusion, modeling the meniscus and individual cartilage was found to affect the pressure distribution in the mouse knee joint under compressive load and should be included in realistic models for assessing the effect of interventions preclinically.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Validation and evaluation of subject-specific finite element models of the pediatric knee
    Ayda Karimi Dastgerdi
    Amir Esrafilian
    Christopher P. Carty
    Azadeh Nasseri
    Alireza Yahyaiee Bavil
    Martina Barzan
    Rami K. Korhonen
    Ivan Astori
    Wayne Hall
    David John Saxby
    Scientific Reports, 13
  • [2] Representation of bone heterogeneity in subject-specific finite element models for knee
    Au, Anthony G.
    Liggins, Adrian B.
    Raso, V. James
    Carey, Jason
    Amirfazli, A.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2010, 99 (02) : 154 - 171
  • [3] Validation and evaluation of subject-specific finite element models of the pediatric knee
    Dastgerdi, Ayda Karimi
    Esrafilian, Amir
    Carty, Christopher P.
    Nasseri, Azadeh
    Yahyaiee Bavil, Alireza
    Barzan, Martina
    Korhonen, Rami K.
    Astori, Ivan
    Hall, Wayne
    Saxby, David John
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [4] Validation of multiple subject-specific finite element models of unicompartmental knee replacement
    Tuncer, Mahmut
    Cobb, Justin P.
    Hansen, Ulrich N.
    Amis, Andrew A.
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (10) : 1457 - 1464
  • [5] Efficient development of subject-specific finite element knee models: Automated identification of soft-tissue attachments
    Malbouby, Vahid
    Gibbons, Kalin D.
    Bursa, Nurbanu
    Ivy, Amanda K.
    Fitzpatrick, Clare K.
    JOURNAL OF BIOMECHANICS, 2025, 178
  • [6] In vivo evaluation of the subject-specific finite element model for knee joint cartilage contact area
    Kyoung-Tak Kang
    Sung-Hwan Kim
    Juhyun Son
    Young Han Lee
    Heoung-Jae Chun
    International Journal of Precision Engineering and Manufacturing, 2015, 16 : 1171 - 1177
  • [7] In vivo evaluation of the subject-specific finite element model for knee joint cartilage contact area
    Kang, Kyoung-Tak
    Kim, Sung-Hwan
    Son, Juhyun
    Lee, Young Han
    Chun, Heoung-Jae
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2015, 16 (06) : 1171 - 1177
  • [8] Development and evaluation of a new procedure for subject-specific tensioning of finite element knee ligaments
    Lahkar, Bhrigu K.
    Rohan, Pierre-Yves
    Pillet, Helene
    Thoreux, Patricia
    Skalli, Wafa
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (11) : 1195 - 1205
  • [9] Development and validation of subject-specific finite element models for blunt trauma study
    Shen, Weixin
    Niu, Yuqing
    Mattrey, Robert F.
    Fournier, Adam
    Corbeil, Jackie
    Kono, Yuko
    Stuhmiller, James H.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (02):
  • [10] Protocol for constructing subject-specific biomechanical models of knee joint
    Yang, N. H.
    Canavan, P. K.
    Nayeb-Hashemi, H.
    Najafi, B.
    Vaziri, A.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2010, 13 (05) : 589 - 603