Quality control for the evaluation of inter- and intraindividual variability in routine semen analysis: results of an international workshop

被引:0
|
作者
Auger, J
Eustache, F
Ducot, B
Spira, A
Jouannet, P
机构
[1] Hop Cochin, Serv Biol Reprod, F-75674 Paris, France
[2] CHU Bicetre, INSERM U292, Le Kremlin Bicetre, France
关键词
D O I
10.1093/humrep/14.Suppl_3.64
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
O117
引用
收藏
页码:64 / 65
页数:2
相关论文
共 25 条
  • [1] Obstetric MR pelvimetry: Reference values and evaluation of inter- and intraobserver error and intraindividual variability
    Keller, TM
    Rake, A
    Michel, SCA
    Seifert, B
    Efe, G
    Treiber, K
    Huch, R
    Marincek, B
    Kubik-Huch, RA
    RADIOLOGY, 2003, 227 (01) : 37 - 43
  • [2] Interobserver Variability in Semen Analysis: Findings From a Quality Control Initiative
    Siddharth, Kumar
    Kumar, Tribhuwan
    Zabihullah, Md.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)
  • [3] The use of latex beads in external quality assurance and internal quality control for routine semen analysis
    Zuvela, Emily
    Junk, Stephen
    Moska, Natalie
    Matson, Phillip
    REPRODUCTIVE BIOLOGY, 2011, 11 (03) : 264 - 275
  • [4] High variability in results of semen analysis in andrology laboratories in Tuscany (Italy): the experience of an external quality control (EQC) programme
    Filimberti, E.
    Degl'Innocenti, S.
    Borsotti, M.
    Quercioli, M.
    Piomboni, P.
    Natali, I.
    Fino, M. G.
    Caglieresi, C.
    Criscuoli, L.
    Gandini, L.
    Biggeri, A.
    Maggi, M.
    Baldi, E.
    ANDROLOGY, 2013, 1 (03) : 401 - 407
  • [5] Evaluation of the Variability of Vibration Measurement Results in Rolling Bearing Quality Control
    Zmarzly, Pawel
    Wrzochal, Mateusz
    Adamczak, Stanislaw
    APPLIED SCIENCES-BASEL, 2025, 15 (02):
  • [6] Variability in progenitor assay results: Evaluation with quality control specimens.
    Burger, SR
    Fautsch, SK
    Kadidlo, D
    Stroncek, DF
    McCullough, J
    BLOOD, 1996, 88 (10) : 3707 - 3707
  • [7] A QUALITY-CONTROL STUDY TO ASSESS THE INTER-LABORATORY VARIABILITY OF ROUTINE ESTROGEN AND PROGESTERONE-RECEPTOR ASSAYS
    ZAVA, DT
    WYLERVONBALLMOOS, A
    GOLDHIRSCH, A
    ROOS, W
    TAKAHASHI, A
    EPPENBERGER, U
    ARRENBRECHT, S
    MARTZ, G
    LOSA, G
    GOMEZ, F
    GUELPA, C
    EUROPEAN JOURNAL OF CANCER & CLINICAL ONCOLOGY, 1982, 18 (08): : 713 - 721
  • [8] Evaluation of right ventricular function with multidetector computed tomography: comparison with magnetic resonance imaging and analysis of inter- and intraobserver variability
    Mueller, Mira
    Teige, Florian
    Schnapauff, Dirk
    Hamm, Bernd
    Dewey, Marc
    EUROPEAN RADIOLOGY, 2009, 19 (02) : 278 - 289
  • [9] INTER-LABORATORY VARIABILITY IN DETERMINATION OF SERUM THEOPHYLLINE CONCENTRATIONS - RESULTS OF A QUALITY-CONTROL PROGRAM
    BOOBIS, S
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1979, 7 (04) : P437 - P438
  • [10] External quality control and training of semen analysis in the Netherlands: starting point for further reduction of outcome variability
    Lemmens, Louise
    van den Hoven, Leonie
    van Vrouwerff, Netty J.
    Braat, Didi D. M.
    Nelen, Willianne L. D. M.
    Spath, Marian A.
    Wetzels, Alex M. M.
    ASIAN JOURNAL OF ANDROLOGY, 2022, 24 (01): : 15 - 20