Exercise Capacity and Functional Performance in Heart Failure Patients Supported by a Left Ventricular Assist Device at Discharge From Inpatient Rehabilitation

被引:28
|
作者
Schmidt, Thomas [1 ,2 ]
Bjarnason-Wehrens, Birna [2 ]
Bartsch, Petra [1 ]
Deniz, Ezin [3 ]
Schmitto, Jan [3 ]
Schulte-Eistrup, Sebastian [4 ]
Willemsen, Detlev [1 ]
Reiss, Nils [1 ]
机构
[1] Schuchtermann Klin Bad Rothenfelde, Dept Cardiac Rehabil, Bad Rothenfelde, Lower Saxony, Germany
[2] German Sports Univ Cologne, Inst Cardiol & Sports Med, Dept Prevent & Rehabilitat Sport & Exercise Med, Cologne, Germany
[3] Hannover Med Sch, Dept Cardiothorac Transplantat & Vasc Surg, Hannover, Germany
[4] Schuchtermann Klin Bad Rothenfelde, Dept Cardiac Surg, Bad Rothenfelde, Lower Saxony, Germany
关键词
Heart failure; Left ventricular assist device; Cardiac rehabilitation; Exercise capacity; Functional performance; 6-MINUTE WALK TEST; QUALITY-OF-LIFE; CARDIAC REHABILITATION; HEALTH-STATUS; EFFICACY; IMPLANTATION; ASSOCIATION; OUTCOMES; TRANSPLANTATION; OUTPATIENTS;
D O I
10.1111/aor.12936
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Adequate physical and functional performance is an important prerequisite for renewed participation and integration in self-determined private and (where appropriate) professional lives following left ventricular assist device (LVAD) implantation. During cardiac rehabilitation (CR), individually adapted exercise programs aim to increase exercise capacity and functional performance. A retrospective analysis of cardiopulmonary exercise capacity and functional performance in LVAD patients at discharge from a cardiac rehabilitation program was conducted. The results from 68 LVAD patients (59 males, 9 females; 55.9 +/- 11.7 years; 47 HVAD, 2 MVAD, 15 HeartMate II, 4 HeartMate 3, and 4 different implanting centers) were included in the analysis. Exercise capacity was assessed using a cardiopulmonary exercise test on a bicycle ergometer (ramp protocol; 10 W/min). The 6-min walk test was used to determine functional performance. At discharge from CR (53 +/- 17 days after implantation), the mean peak work load achieved was 62.2 +/- 19.3 W (38% of predicted values) or 0.79 +/- 0.25 W/kg body weight. The mean cardiopulmonary exercise capacity (relative peak oxygen uptake) was 10.6 +/- 5.3 mL/kg/min (37% of predicted values). The 6-min walk distance improved significantly during CR (325 +/- 106 to 405 +/- 77 m; P<0.01). No adverse events were documented during CR. The results show that, even following LVAD implantation, cardiopulmonary exercise capacity remains considerably restricted. In contrast, functional performance, measured by the 6-min walk distance, reaches an acceptable level. Light everyday tasks seem to be realistically surmountable for patients, making discharge from inpatient rehabilitation possible. Long-term monitoring is required in order to evaluate the situation and how it develops further.
引用
收藏
页码:22 / 30
页数:9
相关论文
共 50 条
  • [1] Exercise in heart failure patients supported with a left ventricular assist device
    Jung, Mette Holme
    Gustafsson, Finn
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (04): : 489 - 496
  • [2] Exercise Capacity and Functional Performance in Patients With an HVAD Left Ventricular Assist Device (LVAD): Development 6 Month After Discharge From Cardiac Rehabilitation
    Schmidt, T.
    Bjarnason-Wehrens, B.
    Mommertz, S.
    Nitters-Daske, A.
    Potthoff, C. Meyer genannt
    Schulte-Eistrup, S.
    Reiss, N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S286 - S287
  • [3] Functional Outcomes of Left Ventricular Assist Device Patients Receiving Inpatient Rehabilitation
    Coyle, L. A.
    Milkevitch, K.
    Adair, R.
    Tatooles, A.
    Bhat, G.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (04): : S337 - S338
  • [4] Invasive exercise haemodynamics predict functional capacity in patients with advanced heart failure implanted with a left ventricular assist device
    Koshy, A.
    Green, T.
    Fernandez, O. G.
    Schueler, S.
    Jakovljevic, D.
    MacGowan, G.
    EUROPEAN HEART JOURNAL, 2018, 39 : 1067 - 1068
  • [5] Development of exercise-related values in heart failure patients supported with a left ventricular assist device
    Schmidt, Thomas
    Bjarnason-Wehrens, Birna
    Mommertz, Stephanie
    Schulte-Eistrup, Sebastian
    Willemsen, Detlev
    Sindermann, Juergen
    Predel, Hans-Georg
    Reiss, Nils
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2019, 42 (04): : 201 - 206
  • [6] Acute Inpatient Rehabilitation After Left Ventricular Assist Device Implantation for Congestive Heart Failure
    Nissinoff, Jeffrey
    Tian, Fang
    Therattil, Maya
    Salvarrey, Rosa M.
    Lee, Se Won
    PM&R, 2011, 3 (06) : 586 - 589
  • [7] Peak Exercise Capacity is a Poor Indicator of Functional Capacity for Patients Supported by a Continuous Flow Left Ventricular Assist Device
    Nahumi, Nadav
    Garan, Arthur R.
    Uriel, Nir
    Han, Jason
    Morrison, Kerry A.
    Thomas, Sunu S.
    Yuzefpolskaya, Melana
    Colombo, Paolo C.
    Jorde, Ulrich P.
    CIRCULATION, 2013, 128 (22)
  • [8] Comparison of functional capacity in patients with end-stage heart failure following implantation of a left ventricular assist device versus heart transplantation:: Results of the experience with left ventricular assist device with exercise trial
    Jaski, BE
    Lingle, RJ
    Kim, J
    Branch, KR
    Goldsmith, R
    Johnson, MR
    Lahpor, JR
    Icenogle, TB
    Piña, I
    Adamson, R
    Favrot, LK
    Dembitsky, WP
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 1999, 18 (11): : 1031 - 1040
  • [9] Inpatient Rehabilitation Outcomes for Patients Receiving Left Ventricular Assist Device
    Alsara, Osama
    Reeves, Ronald K.
    Pyfferoen, Mary D.
    Trenary, Tamra L.
    Engen, Deborah J.
    Vitse, Merri L.
    Kessler, Stacy M.
    Kushwaha, Sudhir S.
    Clavell, Alfredo L.
    Thomas, Randal J.
    Lopez-Jimenez, Francisco
    Park, Soon J.
    Perez-Terzic, Carmen M.
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2014, 93 (10) : 860 - 868
  • [10] Muscular Strength Predicts Functional Capacity in Left Ventricular Assist Device Supported Patients
    Loyaga-Rendon, R. Y.
    Pamboukian, S. V.
    Acharya, D.
    Tallaj, J.
    Siric, F.
    Hoopes, C.
    Holman, W.
    Kirklin, J.
    Plaisance, E. P.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S23 - S23