A study of tetraethylammonium ion transfer across a micro liquid/liquid interface

被引:0
|
作者
Tong, YH [1 ]
Shao, YH [1 ]
Wang, EK [1 ]
机构
[1] Acad Sinica, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Peoples R China
关键词
cyclic voltammetric measurements; micropipette; liquid/liquid interfaces; simple ion transfer;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tetraethylammonium (TEA(+)) ion transfer across micro-liquid/liquid interface has been studied with cyclic voltammetric measurements. The results showed that voltammetric responses of the currents obtained were peak and steady-state for TEA(+) transfer from inside and outside of the micropipette when the radius was bigger than 3 mum. However, the currents were pseudo-steady-state when the micropipette diameters were less than 3 mum. The values of i(p) decreased with decreasing concentration of TEA(+). Peak current was proportional to the square root of the scan rate and it obeyed a Randles-Sevcik type relationship. The mechanism of mass transport across a liquid/ liquid microinterface for TEA(+) system was aslo discussed.
引用
收藏
页码:1241 / 1245
页数:5
相关论文
共 12 条