A glassy carbon electrode modified with poly(eriochrome black T) for sensitive determination of adenine and guanine

被引:38
|
作者
Wei, Youli [1 ]
Luo, Liqiang [1 ]
Ding, Yaping [1 ]
Liu, Xiao [1 ]
Chu, Yuliang [2 ]
机构
[1] Shanghai Univ, Dept Chem, Shanghai 200444, Peoples R China
[2] Shanghai Univ, Instrumental Anal & Res Ctr, Shanghai 200444, Peoples R China
基金
中国国家自然科学基金;
关键词
Poly(eriochrome black T) film; Adenine; Guanine; Square wave voltammetry; COMPOSITE FILM; ELECTROCHEMICAL DETERMINATION; MASS-SPECTROMETRY; PASTE ELECTRODE; ASCORBIC-ACID; FABRICATION; OXIDATION; THYMINE; PURINE; DNA;
D O I
10.1007/s00604-013-1007-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A thin film of poly(eriochrome black T) was deposited on the surface of glassy carbon electrode by cyclic voltammetry, and this system is shown to enable the sensitive determination of adenine (A) and guanine (G). Scanning electron microscopy, Fourier transform infrared spectroscopy and electrochemical impedance spectroscopy were carried out to characterize the film which exhibits excellent electrocatalytic activity toward the oxidation of A and G in 0.1 M phosphate buffer solution (pH 4.0). Square wave voltammetry reveals an oxidation peak at 1084 mV whose current is linearly related to the concentration of A in the range from 0.05 to 1.00 mu M. The oxidation peak for G occurs at 788 mV, and its current is linearly related to the concentration of G in the range from 0.025 to 1.00 mu M. The detection limits are 0.017 mu M for A and 0.008 mu M for G (at S/N = 3), respectively. The modified electrode displays good reproducibility and selectivity for the determination of A and G. The sensor was applied to quantify A and G in fish sperm DNA with satisfactory results.
引用
收藏
页码:887 / 893
页数:7
相关论文
共 50 条
  • [1] A glassy carbon electrode modified with poly(eriochrome black T) for sensitive determination of adenine and guanine
    Youli Wei
    Liqiang Luo
    Yaping Ding
    Xiao Liu
    Yuliang Chu
    Microchimica Acta, 2013, 180 : 887 - 893
  • [2] Sensitive determination of adenine on poly(amidosulfonic acid)-modified glassy carbon electrode
    Zhang, Rui
    Jin, Gendi
    Hu, Xiaoya
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2009, 13 (10) : 1545 - 1552
  • [3] Sensitive determination of adenine on poly(amidosulfonic acid)-modified glassy carbon electrode
    Rui Zhang
    Gendi Jin
    Xiaoya Hu
    Journal of Solid State Electrochemistry, 2009, 13 : 1545 - 1552
  • [4] A highly sensitive method for determination of guanine, adenine and epinephrine using poly-melamine film modified glassy carbon electrode
    Liu, Xiao
    Luo, Liqiang
    Ding, Yaping
    Wu, Qingsheng
    Wei, Youli
    Ye, Daixin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 675 : 47 - 53
  • [5] A glassy carbon electrode modified with electrochemically reduced graphene for simultaneous determination of guanine and adenine
    Zhu, Xiaohua
    Zeng, Lixuan
    Xu, Maotian
    Liang, Yong
    Nan, Junmin
    ANALYTICAL METHODS, 2012, 4 (09) : 2935 - 2939
  • [6] DNA biosensor based on a glassy carbon electrode modified with electropolymerized Eriochrome Black T
    Liheng Wang
    Xiaolei Liao
    Yingtao Ding
    Fei Gao
    Qingxiang Wang
    Microchimica Acta, 2014, 181 : 155 - 162
  • [7] DNA biosensor based on a glassy carbon electrode modified with electropolymerized Eriochrome Black T
    Wang, Liheng
    Liao, Xiaolei
    Ding, Yingtao
    Gao, Fei
    Wang, Qingxiang
    MICROCHIMICA ACTA, 2014, 181 (1-2) : 155 - 162
  • [8] Poly(eriochrome black T) modified electrode for electrosensing of methdilazine
    Shetti, Nagaraj P.
    Ilager, Davalasab
    Malode, Shweta J.
    Monga, Divya
    Basu, Soumen
    Reddy, Kakarla Raghava
    MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING, 2020, 120
  • [9] Simultaneous Determination of Epinephrine and Uric Acid at Poly (Guanine) Modified Glassy Carbon Electrode
    Li, Hongying
    Wang, Xueliang
    ELECTROCHEMISTRY, 2015, 83 (06) : 434 - 439
  • [10] Simultaneous determination of epinephrine and uric acid at poly (guanine) modified glassy carbon electrode
    Department of Chemistry and Chemical Engineering, Heze University, Daxue Road No.1, Heze
    274015, China
    Electrochem, 1600, 6 (434-439): : 434 - 439