Continuous glucose monitoring. Utility and indications

被引:0
|
作者
Litwak, Leon E. [1 ]
Querzoli, Ivanna [2 ]
Musso, Carla [3 ]
Dain, Alejandro [4 ]
Houssay, Solange [4 ]
Proietti, Adrian [5 ]
Costa Gil, Jose E. [5 ]
机构
[1] Hosp Italiano Buenos Aires, Serv Endocrinol Metab & Med Nucl, Buenos Aires, DF, Argentina
[2] Sanofi, Dept Med, Buenos Aires, DF, Argentina
[3] Fdn Favaloro, Diabet, Buenos Aires, DF, Argentina
[4] Hosp Tornu, Buenos Aires, DF, Argentina
[5] Univ Favaloro, Fac Ciencias Med, Buenos Aires, DF, Argentina
关键词
diabetes mellitus; capillary glucose self-monitoring; continuous glucose monitoring; insulin; CLINICAL DECISION-MAKING; BLOOD-GLUCOSE; GLYCEMIC CONTROL; DIABETES CARE; MICROVASCULAR COMPLICATIONS; PUMP THERAPY; TYPE-1; SYSTEM; ASSOCIATION; ADULTS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
An adequate glycemic control prevents and/or delays the development and/or progression of chronic complications in patients with diabetes mellitus (DM). To achieve this control, it is necessary to adjust insulin doses, in type 1 or insulinized type 2 DM persons, based on traditional capillary glucose self-monitoring, which has limitations to generate an adequate data record, is invasive and has low adherence. In contrast, new continuous glucose monitoring (CGM) systems provide more complete and dynamic information, and better compliance. In these systems, a subcutaneous sensor continuously sends glucose values which are captured and stocked by a receptor module. Real-time models (CGMRT) allow continuous and real-time readings of interstitial glucose, whereas CGM-Flash/EI systems require lector approach to sensor module performing intermittent scanning. CGM shows if glycemic levels are increasing or decreasing and how fast it is happening (tendency). CGM decreases glycosylated hemoglobin between 0.53% and 1.0%, as well as time in hypoglycemia by 38%, increasing the time in range of glucose levels, in patients with high adherence. The objectives of this review are to describe the glycemic homeostasis, to evaluate the accuracy of the CGM to interpret the data adequately and finally, based on the information provided by these novel monitoring systems, to suggest a practical way to be added to the traditional intensive insulin therapy.
引用
收藏
页码:44 / 52
页数:9
相关论文
共 50 条
  • [1] Glycated haemoglobin and continuous glucose monitoring.
    Sharp, PS
    Krishna, S
    Rainbow, SJ
    DIABETOLOGIA, 2001, 44 : A238 - A238
  • [2] Continuous Glucose Monitoring. Which is the evidence in Children?
    Suarez-Ayala, Dv
    Forero-Ronderos, C.
    Coll, M.
    Duran, P.
    Cespedes, C.
    ANDES PEDIATRICA, 2021, 92 (04): : 617 - 625
  • [3] Detection of unseen hypoglycemia using continuous glucose monitoring.
    Gross, TM
    Mastrototaro, JJ
    Fredrickson, LP
    DIABETOLOGIA, 2000, 43 : A5 - A5
  • [4] Indications for intracranial pressure monitoring.
    Melon, E
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 1997, 16 (04): : 415 - 419
  • [5] Automated intensive diabetes management based on continuous glucose monitoring.
    Panteleon, A. E.
    Loutseiko, M.
    Stafekhina, V.
    Kopelyan, G.
    Steil, G. M.
    DIABETOLOGIA, 2006, 49 : 593 - 594
  • [6] Real-time continuous glucose monitoring. Panacea or just a distraction?
    Conget, I.
    Gimenez, M.
    AVANCES EN DIABETOLOGIA, 2010, 26 (02): : 71 - 72
  • [7] Utility of continuous glucose monitoring following gastrectomy
    Kubota, Takeshi
    Shoda, Katsutoshi
    Ushigome, Emi
    Kosuga, Toshiyuki
    Konishi, Hirotaka
    Shiozaki, Atsushi
    Kudo, Michihiro
    Arita, Tomohiro
    Murayama, Yasutoshi
    Morimura, Ryo
    Ikoma, Hisashi
    Kuriu, Yoshiaki
    Nakanishi, Masayoshi
    Fujiwara, Hitoshi
    Okamoto, Kazuma
    Fukui, Michiaki
    Otsuji, Eigo
    GASTRIC CANCER, 2020, 23 (04) : 699 - 706
  • [8] Utility of continuous glucose monitoring following gastrectomy
    Takeshi Kubota
    Katsutoshi Shoda
    Emi Ushigome
    Toshiyuki Kosuga
    Hirotaka Konishi
    Atsushi Shiozaki
    Michihiro Kudo
    Tomohiro Arita
    Yasutoshi Murayama
    Ryo Morimura
    Hisashi Ikoma
    Yoshiaki Kuriu
    Masayoshi Nakanishi
    Hitoshi Fujiwara
    Kazuma Okamoto
    Michiaki Fukui
    Eigo Otsuji
    Gastric Cancer, 2020, 23 : 699 - 706
  • [9] Utility of Continuous Glucose Monitoring in Pediatric Diabetic Ketoacidosis
    Pott, Thomas R.
    Vega, Jose M. Jimenez
    Parker, Jessica L.
    Fitzgerald, Robert
    DIABETES, 2019, 68
  • [10] Potential indications of continuous glucose monitoring in type 2 diabetes
    Cros, M. Rigla
    AVANCES EN DIABETOLOGIA, 2010, 26 (02): : 125 - 127