An Experimental Investigation into the Pull-out Capacity of Suction Caissons in Sand

被引:0
|
作者
Kakasoltani, Siamak
Zeinoddini, Mostafa
Abdi, Mahmood R.
Arabzadeh, Hamid
机构
关键词
Experimental Investigation; Suction Caisson; Upright; Tapered; Pull-out; sand;
D O I
暂无
中图分类号
P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
The pull-out performance of conventional suction caissons (with upright walls) has been previously investigated by a number of researchers. However, less attention has been formerly paid to tapered suction caissons. This paper reports some results from an experimental investigation into the pull-out performance of tapered suction caissons. The 1g experiments have been carried out on eight small scale suction caissons. Four specimens have had upright walls while the other four had a positive wall slope of 10%. The caissons have been installed in a soil tank containing very fine saturated silty sand. The caissons have then been subjected to vertical pull-out loads with different speeds. The effects of variations in soil density and pull-out rate on the pull-out capacities have also been investigated. In general, tapered caissons have been noticed to present enhanced pull-out capacities as compared to those from their equivalent upright caissons. The enhancement rate has been found to be more significant in suction caissons with higher aspect ratios. With both upright and tapered caissons the pull-out capacity increases by an increase in the pull-out rate. The pull-out rate effects are more significant with upright caissons in comparison to the corresponding tapered caissons. The density effects, however, are more significant with tapered caissons as compared to their equivalent upright caissons.
引用
收藏
页码:21 / 27
页数:7
相关论文
共 50 条
  • [1] Inclined pull-out capacity of suction caissons
    Supachawarote, C
    Randolph, M
    Gourvenec, S
    PROCEEDINGS OF THE FOURTEENTH (2004) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 2, 2004, : 500 - 506
  • [2] Experimental evaluation of the pull-out behavior of suction caissons in saturated sand soil
    Kayadelen, Cafer
    Altay, Gokhan
    Ozturk, Mitat
    Onal, Yakup
    OCEAN ENGINEERING, 2023, 286
  • [3] Numerical investigation on tapering effects on the pull-out capacity of suction caissons in clay
    Zeinoddini, Mostafa
    Nabipour, Mahmood
    Keyvani, Jafar
    PROCEEDINGS OF THE SEVENTEENTH (2007) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 1- 4, PROCEEDINGS, 2007, : 1410 - 1415
  • [4] Tapered Suction Caissons: A Numerical Investigation into Their Pull-out Performance
    Zeinoddini, M.
    Keyvani, J.
    Nabipour, M.
    CHINA OCEAN ENGINEERING, 2009, 23 (04) : 695 - 707
  • [5] Tapered Suction Caissons:A Numerical Investigation into Their Pull-out Performance
    M.Zeinoddini
    J.Keyvani
    M.Nabipour
    ChinaOceanEngineering, 2009, 23 (04) : 695 - 707
  • [6] Installation and pull-out capacity of stiffened suction caissons in cohesive sediments
    House, AR
    Randolph, MF
    PROCEEDINGS OF THE ELEVENTH (2001) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL II, 2001, : 574 - 580
  • [7] Vacuum penetration and ultimate pull-out capacity of low skirted suction caissons
    Liu Xiao-ke
    Lu Qun
    Lu Shi-wei
    Liu Chun-long
    Guo Shao-long
    ROCK AND SOIL MECHANICS, 2018, 39 (06) : 2089 - 2098
  • [8] Wall slope effects on the vertical pull-out capacity of tapered suction caissons
    Zeinoddini, M.
    Keyvani, J.
    Nabipour, M.
    SCIENTIA IRANICA, 2011, 18 (03) : 313 - 325
  • [9] A Comparison of Pull-out Capacity of Suction Anchors in Clay and Sand
    Du, Jiaqing
    Du, Shouji
    Wang, Zhi
    INTERNATIONAL CONFERENCE MACHINERY, ELECTRONICS AND CONTROL SIMULATION, 2014, 614 : 613 - 617
  • [10] Numerical investigation of pull-out capacity and failure mechanism of suction anchors with mooring line in sand
    Zhang, Min-Hao
    Yin, Zhen-Yu
    Fu, Yong
    OCEAN ENGINEERING, 2023, 280