Evaluation of Load-Rating Procedure for Metal Culverts under Shallow Soil Covers

被引:8
|
作者
Sargand, Shad M. [1 ]
White, Kevin [2 ]
Masada, Teruhisa [1 ]
Wang, Cindy [3 ]
机构
[1] Ohio Univ, Dept Civil Engn, Athens, OH 45701 USA
[2] EL Robinson Engn Ohio, 1801 Watermark Dr,Suite 310, Columbus, OH 43215 USA
[3] Ohio Dept Transportat, Off Struct Engn, Columbus, OH 43223 USA
关键词
D O I
10.1061/(ASCE)PS.1949-1204.0000303
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A research study was carried out recently in Ohio to evaluate the current method employed by Ohio Department of Transportation (ODOT) for load rating corrugated metal culverts installed under extremely shallow soil covers. In the study, six metal culvert structures were carefully selected, instrumented with sensors, and subjected to a series of static and dynamic live load tests. The field test data were analyzed to gain insight into how shallow-installation metal structures respond to live loading. The sensor readings were also used to compute thrust responses in the culverts. Then, the current ODOT load-rating procedure was applied to convert the live load to wall thrust. The thrust forces from the field tests and the calculations were compared. It was observed that the current ODOT procedure is very conservative, as the calculated thrust values were much higher than the field values for five of the six test structures. (C) 2017 American Society of Civil Engineers.
引用
收藏
页数:9
相关论文
共 35 条
  • [1] Load-Rating Procedures and Performance Evaluation of Metal Culverts
    Yeau, Kyong Y.
    Sezen, Halil
    JOURNAL OF BRIDGE ENGINEERING, 2012, 17 (01) : 71 - 80
  • [2] Load Rating Corrugated Metal Culverts with Shallow Soil Cover
    Okafor, Chukwuma C. C.
    Rojas, Olga L. L.
    Liu, Bujing
    Turner, Kelly
    Anderson, J. Brian
    Davidson, James S. S.
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2023, 37 (02)
  • [3] Flexural Capacity Criteria for Load And Resistance Factor Rating of Shallow Covered Corrugated Metal Culverts
    Liu, Bujing
    Brian Anderson, J.
    Davidson, James S.
    TRANSPORTATION RESEARCH RECORD, 2024, 2678 (07) : 1011 - 1025
  • [4] Arching mechanism for large span flexible culverts with shallow soil covers
    Department of Civil Engineering, National Research Centre, Giza, Egypt
    不详
    Foundation Research Laboratory, Faculty of Engineering, Cairo University, Giza, Egypt
    不详
    J. Eng. Appl. Sci., 1 (1):
  • [5] Selection of Soil Stiffnesses for the Load Rating of In-Service Culverts
    Mousavi, S. Mehdi
    Jayawickrama, Priyantha W.
    Wood, Timothy A.
    Lawson, William D.
    GEOTECHNICAL FRONTIERS 2017: TRANSPORTATION FACILITIES, STRUCTURES, AND SITE INVESTIGATION, 2017, (277): : 223 - 232
  • [6] Assessment of Simplified Rating Factor Methodology for Shallow Cover Metal Culverts
    Liu, Bujing
    Anderson, Brian J.
    Davidson, James S.
    APPLIED SCIENCES-BASEL, 2024, 14 (24):
  • [7] Influence of Cover Soil Depth on the Load Rating of Reinforced Concrete Box Culverts
    Wood, Timothy A.
    Lawson, William D.
    Jayawickrama, Priyantha W.
    TRANSPORTATION RESEARCH RECORD, 2015, (2511) : 63 - 71
  • [8] Evaluation of Production Models for Load Rating Reinforced Concrete Box Culverts
    Wood, Timothy A.
    Lawson, William D.
    Jayawickrama, Priyantha W.
    Newhouse, Charles D.
    JOURNAL OF BRIDGE ENGINEERING, 2015, 20 (01)
  • [9] Live-Load Effect in Reinforced Concrete Box Culverts under Soil Fill
    Orton, Sarah L.
    Loehr, J. Erik
    Boeckmann, Andrew
    Havens, Garrett
    JOURNAL OF BRIDGE ENGINEERING, 2015, 20 (11)
  • [10] Responses of soil microarthropods to soil metal fractions under different mediterranean vegetation covers
    Santorufo, Lucia
    Memoli, Valeria
    Santini, Giorgia
    Di Natale, Gabriella
    Trifuoggi, Marco
    Barile, Rossella
    Maisto, Giulia
    CATENA, 2023, 232