Feasibility of magnetic resonance electrical impedance tomography (MREIT) conductivity imaging to evaluate brain abscess lesion: In vivo canine model

被引:23
|
作者
Oh, Tong In [1 ]
Jeong, Woo Chul [1 ]
McEwan, Alistair [1 ,2 ]
Park, Hee Myung [3 ,4 ]
Kim, Hyung Joong [1 ]
Kwon, Oh In [5 ]
Woo, Eung Je [1 ]
机构
[1] Kyung Hee Univ, Dept Biomed Engn, Yongin, Gyeonggi, South Korea
[2] Univ Sydney, Sch Elect & Informat Engn, Sydney, NSW 2006, Australia
[3] Konkuk Univ, Basic & Diagnost Vet Specialist Program Anim Dis, Seoul, South Korea
[4] Konkuk Univ, Dept Vet Internal Med, Seoul, South Korea
[5] Konkuk Univ, Dept Math, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
magnetic resonance electrical impedance tomography (MREIT); electrical conductivity; brain abscess; magnetic flux density; PROTON MR SPECTROSCOPY; DIELECTRIC-PROPERTIES; TUMORS; LIVER; POSTMORTEM; ALGORITHM; CARCINOMA; ABLATION; TISSUES;
D O I
10.1002/jmri.23960
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To show the feasibility of magnetic resonance electrical impedance tomography (MREIT) conductivity imaging in terms of its capability to provide new contrast information of abscess lesion and characterize time-course variations before and after the induction of brain abscess. Materials and Methods: Brain abscess was induced in healthy beagles by a direct inoculation method using Staphylococcus pseudintermedius. After the induction, four electrodes were attached on the head and the dog was placed inside the magnetic resonance imaging (MRI) bore. Using a current source, we injected a current of amplitude 5 mA and a pulse width of 81 msec. A multi-echo ICNE pulse sequence was used to obtain the magnetic flux density (B-z) data. Results: The relative conductivity contrast ratios (rCCR, %) of abscess lesion were significantly changed by the postinduction time (P < 0.01). The rCCRs of central abscess lesions were higher than the surrounding area at 6, 12, and 18 hours (P < 0.01). Over 12 hours, the relationship between the induction time and rCCR showed a positive correlation followed by a negative correlation (P < 0.01). Conclusion: We performed in vivo disease model animal experiments to validate the MREIT technique providing conductivity information of tissues in situ to be utilized in clinical applications.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 50 条
  • [1] Electrical conductivity imaging by magnetic resonance electrical impedance tomography (MREIT)
    Oh, SH
    Han, JY
    Lee, SY
    Cho, MH
    Lee, BI
    Woo, EJ
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (04) : 875 - 878
  • [2] Magnetic Resonance Electrical Impedance Tomography (MREIT): conductivity and current density imaging
    Seo, JK
    Kwon, O
    Woo, EJ
    SECOND INTERNATIONAL CONFERENCE ON INVERSE PROBLEMS: RECENT THEORETICAL DEVELOPMENTS AND NUMERICAL APPROACHES, 2004, 2005, 12 : 140 - 155
  • [3] In vivo magnetic resonance electrical impedance tomography of canine brain: Disease model study of ischemia and abscess
    Kim Y.T.
    Jeong W.C.
    Minhas A.S.
    Lim C.Y.
    Park H.M.
    Kim H.J.
    Woo E.J.
    Biomedical Engineering Letters, 2011, 1 (1) : 56 - 61
  • [4] Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging
    Woo, Eung Je
    Seo, Jin Keun
    PHYSIOLOGICAL MEASUREMENT, 2008, 29 (10) : R1 - R26
  • [5] Conductivity imaging of canine body using 3T magnetic resonance electrical impedance tomography (MREIT) system
    Kim, H. J.
    Kim, Y. T.
    Jeong, W. C.
    Minhas, A. S.
    Lim, C. Y.
    Park, H. M.
    Woo, E. J.
    SCIENTIA IRANICA, 2011, 18 (06) : 1505 - 1510
  • [6] Magnetic Resonance Electrical Impedance Tomography (MREIT)
    Seo, Jin Keun
    Woo, Eung Je
    SIAM REVIEW, 2011, 53 (01) : 40 - 68
  • [7] Fast conductivity imaging in magnetic resonance electrical impedance tomography (MREIT) for RF ablation monitoring
    Kwon, Oh In
    Chauhan, Munish
    Kim, Hyung Joong
    Jeong, Woo Chul
    Wi, Hun
    Oh, Tong In
    Woo, Eung Je
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2014, 30 (07) : 447 - 455
  • [8] Electrical conductivity imaging using gradient Bz decomposition algorithm in magnetic resonance electrical impedance tomography (MREIT)
    Park, C
    Kwon, O
    Woo, EJ
    Seo, JK
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (03) : 388 - 394
  • [9] A Novel Conductivity Reconstruction Algorithm for Magnetic Resonance Electrical Impedance Tomography (MREIT)
    Wang, Yuyu
    Wang, Huixian
    Yang, Wenhui
    Hu, Xiaolin
    Song, Tao
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3976 - 3979
  • [10] Animal and Human Imaging Experiments in Magnetic Resonance Electrical Impedance Tomography (MREIT)
    Woo, Eung Je