Fundamental Reference Signal Generation for Shunt Active Filter for Harmonic and Reactive Power Mitigation using Xilinx System Generator

被引:0
|
作者
Sriranjani, R. [1 ]
Jayalalitha, S. [1 ]
机构
[1] SASTRA Univ, Sch Elect & Elect Engn, Thanjavur, Tamil Nadu, India
关键词
Harmonics; Power factor; Reactive power; Shunt active filter; MATLAB; FPGA; COMPENSATION; REDUCTION;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper proposes the design of the controller using a Xilinx system generator for Shunt active filter (SAF) to alleviate harmonics and reactive power supply mains. This control algorithm evolved from elemental synchronous reference frame engenders the fundamental reference signal from the load current with a phase shift of zero angle. The proposed algorithm is tested in harmonic load and reactive load and it is verified by implementing the model in MATLAB Xilinx system generator. The comparison study was carried out for the proposed algorithm and conventional algorithm and the results are validated through control of hardware circuit using the FPGA processor.
引用
收藏
页码:2404 / 2410
页数:7
相关论文
共 50 条
  • [1] Instantaneous d frame driven shunt active filter for harmonics and reactive power mitigation using Xilinx System Generator
    Sriranjani, Ramakrishnan
    Jayalalitha, Subbaiah
    AIN SHAMS ENGINEERING JOURNAL, 2019, 10 (01) : 15 - 22
  • [2] Reference Signal Generation For Shunt Active Power Filter Using Adaptive Filtering Approach
    Tamboli, Dipti A.
    Chile, R. H.
    2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL INSTRUMENTATION AND CONTROL (ICIC), 2015, : 766 - 770
  • [3] Active Power Filter for Harmonic Mitigation in a Distributed Power Generation System
    Dash, Ritesh
    Paikray, Priyanka
    Swain, S. C.
    2017 INNOVATIONS IN POWER AND ADVANCED COMPUTING TECHNOLOGIES (I-PACT), 2017,
  • [4] Harmonic mitigation in three phase three wire system using shunt active power filter
    Lakra, Rajeev
    Kasireddy, Idamakanti
    Singh, Arun Kumar
    2018 INTERNATIONAL CONFERENCE ON RECENT INNOVATIONS IN ELECTRICAL, ELECTRONICS & COMMUNICATION ENGINEERING (ICRIEECE 2018), 2018, : 2753 - 2756
  • [5] Hardware In Loop Cosimulation of LMS Algorithm for Shunt Active Filter to Mitigate Harmonics and Reactive Power - Xilinx System Generator Approach
    Sriranjani, R.
    Jayalalitha, S.
    CONTROL ENGINEERING AND APPLIED INFORMATICS, 2019, 21 (04): : 71 - 79
  • [6] A PROPOSED REFERENCE CURRENT SIGNAL GENERATION TECHNIQUE FOR SHUNT ACTIVE POWER FILTER
    Nayak, B.
    Misra, B.
    Mohapatra, A.
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2018, 13 (06) : 1834 - 1849
  • [7] Selective harmonic current mitigation with shunt active power filter
    Asiminoaei, Lucian
    Hansen, Steffan
    Lascu, Cristian
    Blaabjerg, Frede
    2007 EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-10, 2007, : 3715 - +
  • [8] Research on Reference Signal of Shunt Active Power Filter
    Xu, Chengtao
    Chen, Long
    Cai, Shengnian
    Qin, Ran
    Pang, Baolin
    Sui, Liping
    2013 THIRD INTERNATIONAL CONFERENCE ON INSTRUMENTATION & MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC), 2013, : 1041 - 1044
  • [9] Realization of active power filter based on indirect current control algorithm using Xilinx system generator for harmonic elimination
    Dash, Santanu Kumar
    Panda, Gayadhar
    Ray, Pravat Kumar
    Pujari, Sashank Sekhar
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 74 : 420 - 428
  • [10] Harmonic Suppression and Reactive Power Compensation of Shunt Active Power Filter
    Wei, Ping
    Chen, Houquan
    Cheng, Dengliang
    2009 THIRD INTERNATIONAL SYMPOSIUM ON INTELLIGENT INFORMATION TECHNOLOGY APPLICATION, VOL 1, PROCEEDINGS, 2009, : 386 - 390